tecnopress SERIES E115X E140X E190X...xR These burners are characterized by the “spiral” line typical of the series TECNOPRESS. They are suitable both for big and for small outputs up to 1900 kW. Moreover they are suitable to burn either natural gas or light oil thanks to the adjustable combustion head which allows a good performance with both fuels. The control panel is printed with a mimic diagram fitted with neon lamps to indicate the different stages of the burner operation. Like all other models, they can work with standard and long blast tube. If the blast tube is shorter than the standard one, a spacer is available to adjust the insertion length into the combustion chamber. All regulations and settings devices are simple and practical for both fuels thanks to high quality leverages. This new series of burners integrates the well known performance and reliability characteristics and has the new air inlet system with built-in silencer and the new combustion head that is particularly Eco friendly (gas side <80mg/kWh class 3 EN 676). Back-pressure in combustion chamber (mbar)
Open the catalog to page 1TECHNICAL DETAILS Fan motor kW Pump motor Gas connections Noise level kW dBA For the configuration of the gas train, see page 113 Electric power supply Type Model TUTTI I DIRITTI SONO RISERVATI E PROPRIETA' DI CIB UNIGAS S.P.A. SENZA CONSENSO SCRITTO DI CIB UNIGAS S.P.A. QUESTO DISEGNO NON PUO' ESSERE RIPRODOTTO O IN ALCUN MODO ESSERE UTILIZ ZATO PER LA PRODUZIONE DEI COMPONENTI O ASSIEME ILLUSTRA TO NE ESSERE TRASMESSO A ALTRE PARTI. OGNI INFRAZIONE VERRA PERSEGUITA LEGALMENTE. ALL PROPRIETARY RIGHTS RESEVED BY CIB UNIGAS S.P.A. THIS DRAWING SHALL NOT BE REPRODUCED OR IN ANY WAY UTILIZED...
Open the catalog to page 2Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Attention: the graph shows the value of the gas output (kW) against the corresponding pressure without the combustion chamber back pressure. To know the minimum gas pressure at gas train, in order to get the gas output, it is necessary to add the boiler back pressure to the value read on the curve.
Open the catalog to page 3All CIB UNIGAS S.p.A. catalogs and technical brochures
-
Burners for Industrial Applications
252 Pages
-
Medium small burners
204 Pages
-
Medium large burners
324 Pages
-
Catalogue Professional 2022
332 Pages
-
Catalogue Residential 2022
224 Pages
-
Catalogue Residential 2020
216 Pages
-
681 NOVANTA [kW 470 ÷ 3.100]
3 Pages
-
629 NOVANTA [KW 440 ÷ 3.100]
3 Pages
-
195 MINIFLAM [kW 29 ÷ 209]
1 Pages
-
172 IDEA [kW 70 ÷ 560]
3 Pages
-
39 IDEA [kW 19 ÷ 85]
4 Pages
-
315 IDEA [kW 65 ÷ 570]
4 Pages
-
307 IDEA [kW 35 ÷ 200]
4 Pages
-
TECNOPRESS [kW 160 ÷ 2300]
2 Pages
-
IDEA 35 / 60-70-90 / 120-140-200
16 Pages
-
2011 Catalogue
194 Pages