39 IDEA [kW 19 ÷ 85]

39 IDEA [kW 19 ÷ 85]

39 IDEA [kW 19 ÷ 85]

Product catalog summary
Overview: The document provides technical specifications and details for the IDEA series of gas burners, specifically the NG35, NG70, and NG90 models. These burners are designed with tangential ventilation and are part of a new line of Low NOx Class 2 burners, emitting less than 120 mg/KWh. They are available in five different aluminum housings.
Specifications:
  • NG35: Power range from 20 to 41 kW, electric power supply of 230 V 1N ac, fan motor power of 0.075 kW, and gas connection of ½”.
  • NG70: Power range from 30 to 70 kW, electric power supply of 230 V 1N ac, fan motor power of 0.1 kW, and gas connection of ½”.
  • NG90: Power range from 40 to 85 kW, electric power supply of 230 V 1N ac, fan motor power of 0.1 kW, and gas connection options of ½” or ¾”.
Procedures: The NG35 burner can be configured to use external combustion air upon request, which involves a watertight and airtight air intake connected via a 10-meter duct.
Technical Details: The document includes detailed dimensions for each burner model, specifying overall dimensions and packaging dimensions. It also provides suggested boiler drilling configurations.
Performance Graphs: Graphs illustrate the relationship between gas output (kW) and minimum inlet gas pressure (mbar), highlighting the need to consider boiler back pressure when determining minimum gas pressure requirements.
Recommendations: For configuring the gas train, refer to page 113 of the document for detailed instructions.
See more

Catalog excerpts

39 IDEA [kW 19 ÷ 85]-1

These burners with tangential ventilation are, in terms of dimensions and output, the smallest burners of the new line IDEA gas Low NOx Class 2 (< 120 mg/KWh) available in five different aluminium housings. NG35 burner can be arranged to use external combustion air on request. In this case the burner will be supplied with a watertight and airtight air intake, linked outside by means of a duct ten meters long. Back-pressure in combustion chamber (mbar)

 Open the catalog to page 1
39 IDEA [kW 19 ÷ 85]-2

TECHNICAL DETAILS Type Model Electric power supply 230 V 1N ac 230 V 1N ac 230 V 1N ac 230 V 1N ac 230 V 1N ac For the configuration of the gas train, see page 113. Suggested boiler drilling Burner flange ** Approximate values

 Open the catalog to page 2
39 IDEA [kW 19 ÷ 85]-3

Back-pressure in combustion chamber (mbar) 3,0 Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) 3,0 0 Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar)

 Open the catalog to page 3
39 IDEA [kW 19 ÷ 85]-4

Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Attention: the graph shows the value of the gas output (kW) against the corresponding pressure without the combustion chamber back pressure. To know the minimum gas pressure at gas train, in order to get the gas output, it is necessary to add the boiler back pressure to the value read on the curve.

 Open the catalog to page 4