Product catalog summary
Introduction
CIB UNIGAS introduces the IDEA Low NOx Class 2 burners, designed for small and medium appliances with tangential ventilation. These burners are suitable for boilers with high back pressure and are the most powerful in the IDEA range.
Specifications
The burners are available in models NG280, NG350, NG400, and NG550, with varying power outputs and back pressure capabilities. The packaging dimensions and weights are specified for each model, with NG280/350/400 having dimensions of 1120x440x580 mm and a weight of 42 kg, while NG550 measures 1200x460x630 mm and weighs 55 kg.
Technical Details
Each model has specific power ranges, electric power supply requirements, and gas connection sizes. For example, the NG280 model ranges from 65 to 300 kW with a 230 V 1N ac supply and gas connections ranging from 1” to 1”½.
Graphical Data
The document includes graphs showing the relationship between gas output (kW) and minimum inlet gas pressure (mbar) for each model. It is noted that the minimum gas pressure at the gas train must account for the boiler back pressure in addition to the values shown on the curves.
Recommendations
For configuring the gas train, users are directed to refer to page 113 for detailed instructions.
See more

Catalog excerpts

315 IDEA [kW 65 ÷ 570]-1

With the new line IDEA Low NOx Class 2 (< 120 mg/kWh), CIB UNIGAS presents on the market a new conception of modern and functional burners for small and medium appliances with a tangential ventilation. These burners, which are the most powerful of the range IDEA, are particulary suitable to work on the boilers with high back pressure. Back-pressure in combustion chamber (mbar)

 Open the catalog to page 1
315 IDEA [kW 65 ÷ 570]-2

Electric power supply For the configuration of the gas train, see page 113. Suggested boiler drilling Burner flange stand. exten stand. exten

 Open the catalog to page 2
315 IDEA [kW 65 ÷ 570]-3

Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar)

 Open the catalog to page 3
315 IDEA [kW 65 ÷ 570]-4

Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Attention: the graph shows the value of the gas output (kW) against the corresponding pressure without the combustion chamber back pressure. To know the minimum gas pressure at gas train, in order to get the gas output, it is necessary to add the boiler back pressure to the value read on the curve.