DYNACIAT POWER - NA1091B
12Pages

{{requestButtons}}

Catalog excerpts

DYNACIAT POWER - NA1091B - 1

WATER-TO-WATER HEAT PUMP - WATER CHILLER Dynaciat Smart equipment that boosts performance

Open the catalog to page 1
DYNACIAT POWER - NA1091B - 2

The name in unsurpassed comfort, superior performance, and energy excellence Cooling capacity of up to 720 kW Heating capacity of up to 820 kW GREEN POWER: CIAT's energy label for equipment engineered to meet tomorrow's environmental chal challenges tomorrow's Dynaciat Power, CIAT's first water chiller to be given the GREEN POWER label, illustrates the tremendous potential of CIAT's Research and Innovation teams and their complete mastery of the technologies needed to engineer truly sustainable products. Created by CIAT, the GREEN POWER ecolabel is placed on CIAT products that consume less...

Open the catalog to page 2
DYNACIAT POWER - NA1091B - 3

Proven performance, optimum savings The ESEER characterisation allows better and more accurate assessment of the performance of cooling systems in terms of cooling capacity, energy efficiency and environmental-friendliness. As further proof of its exceptional efficiency, the Dynaciat Power range boasts an ESEER of 6, namely 45% higher than that of conventional R407C units. CE RMAN RFO AL PE ON r SEAS Powe Dynaciat Power makes any green building project easy With its proven high level of energy efficiency and ecolabel design, Dynaciat Power adds tremendous value to any current and future...

Open the catalog to page 3
DYNACIAT POWER - NA1091B - 4

The multi-comfort & multi-purpose solution The solution for heating and cooling Dynaciat Power caters to all the heating and cooling needs of commercial buildings, from shopping centres and hotels to offices and healthcare facilities. Two versions are available to meet your needs: LG for cooling only and LGP for cooling and heating. With a broad chilled water temperature range spanning from +18°C to as low as –12°C, and a hot water outlet temperature as high as +55°C for the heat pump version, Dynaciat Power is the solution for all your cooling and heating applications. Make your industrial...

Open the catalog to page 4
DYNACIAT POWER - NA1091B - 5

Advanced technologies condensed into a small package Connect2: smart, total control The compressors are rotated on and off in order to best balance their use during the life of the system. This greatly reduces fits and starts when starting and considerably increases the service life of the compressors. The optional Soft Starter reduces the inrush current by 25%, thus decreasing disturbances on the network. The Connect2 control takes into account the specific needs of each installation and manages setpoints remotely to increase comfort and energy savings. It also enables Dynaciat Power to...

Open the catalog to page 5
DYNACIAT POWER - NA1091B - 6

Protecting people and the environment ÎR410A refrigerant: an ecological, simple and safe choice Dynaciat Power is CIAT's ecologicallyconscious contribution to helping to preserve the environment, today and for future generations. In designing Dynaciat Power, CIAT made the clear choice to use R410A, a nonozone depleting HFC refrigerant that is not only easy to use, but also ensures a very high level of efficiency by reducing energy consumption and consequently CO2 emissions. The low pressure drop and high transfer coefficient of R410A allow considerably smaller pipes and heat exchangers to...

Open the catalog to page 6
DYNACIAT POWER - NA1091B - 7

So quiet you will forget that it's there Noise has a detrimental effect on worker productivity. Dynaciat Power is available in three versions (Standard, Low Noise, or Xtra Low Noise) to meet even the most demanding noise attenuation requirements of all professions. The Xtra Low Noise version of Dynaciat Power offers a sound pressure level of 55 dB(A) for a cooling capacity of 720 kW. Increase performance and free-up space Mechanical rooms take up valuable space and money. Dynaciat Power is small - nearly half the size of conventional units - but it has a release rate of up to 200 kW/m2. As...

Open the catalog to page 7
DYNACIAT POWER - NA1091B - 8

Installation and maintenance made simple Compact for better integration May be installed against a wall Less than 1 metre wide, Dynaciat Power is slim enough to fit through virtually all doorways. As a result, it can be installed without having to widen the doorways of mechanical rooms in buildings under renovation. Because Dynaciat Power takes up no more floor space than its actual footprint, all handling and installation operations in new buildings are simplified. Dynaciat Power Dynaciat Power, sized for easier installation

Open the catalog to page 8
DYNACIAT POWER - NA1091B - 9

Faster installation, lower cost Dynaciat Power is designed for easy installation: The built-in control transformer reduces wiring to just one cable without a neutral wire. Two-circuit heat exchangers for simplified hydraulic connections. Because R410A uses lower currents, the power cables are smaller and the protection ratings are lower. All these factory features reduce installation time and costs. Users and professionals can count on the quality of the CIAT Group's commissioning and preventive maintenance services and on its extensive range of readily available spare parts. Total...

Open the catalog to page 9
DYNACIAT POWER - NA1091B - 10

A range of high energy efciency solutions The heart of comfort solutions CIAT opens the door to energy excellence and offers you the possibility to benefit from Dynaciat Power's complete range of performance. From shopping centres and hotels, to offices, healthcare facilities and industries, all professional sectors that are looking for powerful, energy-efficient and environmentally-friendly comfort solutions will find exactly what they need with CIAT and Dynaciat Power. High capacity ductable comfort units Slim ductable comfort units Coadis Slim Energy storage Comfort units Fan coil units...

Open the catalog to page 10
DYNACIAT POWER - NA1091B - 11

A range at the leading edge of innovation Dynaciat Power LG-LGP series Cooling mode (1) Eurovent class Eurovent class Cc: Cooling capacity Pi: Input power Eurovent standard conditions (1) Chilled water: 12°C/7°C - Hot water: 30°C/35°C (2) Chilled water inlet: 10°C - Water flow rate in cooling mode - Hot water: 40°C/45°C Dynaciat Power EQUIPMENT Safety switch Control circuit transformer Electrical cabinet wire numbers RS485 MODBUS/JBUS communication interface Water flow controller Master/slave management of two machines Electronic expansion valve (standard on 1800V-2400V) Low Noise version...

Open the catalog to page 11

All CIAT catalogs and technical brochures

  1. RTR-E

    1 Pages

  2. SANICIAT 2

    2 Pages

  3. Hymod

    2 Pages

  4. Magister CW

    2 Pages

  5. CRISTOPIA

    12 Pages

Archived catalogs