AIRCLEAN - AIRCLEAN SANTE - NA0307B
12Pages

{{requestButtons}}

Catalog excerpts

AIRCLEAN - AIRCLEAN SANTE - NA0307B - 1

Ultra-cleanliness has a name Healthcare has its experts

Open the catalog to page 1
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 2

CIAT — the leading name in ai Meets new standards in performance A leader in its field in Europe, CIAT is well-known for its experience in the field of air handling. With 8 production sites around the globe, our R&D potential, and a presence in over 60 countries, we can easily meet the specific restrictions of ultra-cleanliness and the requirements of our customers. Cutting-edge R&D Our research and development teams use powerful CAD tools to design the products of tomorrow and constantly design new technology. Our research centre is one of the largest in Europe. Our work in the field of...

Open the catalog to page 2
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 3

air handling Your partner in high standards Boasting 70 years of experience in heat, aerodynamics, air quality and acoustics, CIAT can design products specifically adapted to the hygiene and performance requirements of sectors and industries that depend on ultra-cleanliness, such as hospitals, pharmaceuticals, chemicals, cosmetics, microelectronics, and micromechanics. Ciat : unique expertise The reliability of our solutions is based on quality at every level, from design to manufacture. Our sound knowledge of state-of-the-art technologies, standards and regulations means that we can...

Open the catalog to page 3
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 4

A dedicated organisation Clean Concept Organisation CIAT’s entire organisation is engineered and adapted to manufacturing AIRCLEAN AHUs in line with total and comprehensive CLEAN CONCEPT quality. Everything — from orders, parts manufacturing and assembling, to packaging, storage and shipment — has been designed around CLEAN CONCEPT. Assembly in clean rooms Our AIRCLEAN air handling range is assembled in a dedicated section of our assembly floor. Alike a clean room, the air in this environment is filtered and maintained at positive pressure. One by one, all parts are cleaned before they...

Open the catalog to page 4
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 5

Clean Concept Services Technical and sales support Our network of engineers and technicians trained in CLEAN CONCEPT air handling products and techniques efficiently provide advice and assistance in finding and selecting solutions that are suitable to all your clean room projects. Performance validation Our Quality Control department and laboratory are equipped with all the measurement instruments needed to deliver expected results (DOP tester, flow, vibration, pressure and acoustic measurements). Our laboratory also offers specific measurement and performance validation services for your...

Open the catalog to page 5
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 6

AIRCLEAN — the ultimate in AIRCLEAN SANTE, Healthca Meets new standards in performance High standards right down to the smallest details Design tailored to the most stringent requirements of new-generation ultra-clean processes. -Maximum efficiency particulate filtration -Includes new concepts in molecular and microbiological filtration. -Reinforced seals withstand required pressure levels. -Easy decontamination. -Total control over quality, from design to manufacturing. -Offset hinges and lockable handles made of composite materials: excellent corrosion resistance, proven strength, easy to...

Open the catalog to page 6
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 7

in ultra-cleanliness care has its experts New-generation design Airclean Airclean Sante - Smooth interior and exterior, - RAL 9010 (white) painted casing, - Mineral wool insulation (long fibres, thickness 50 mm) standard on all sizes, - Panels, inside components and accessories (options) made of 304L or 316L stainless steel, - Specific coatings and steels available for each function, - Flat or inclined stainless steel base (option), - Stainless steel condensate drain pan, - Acoustic baffles have a special surface coating that prevents released particles from contaminating the air flow, -...

Open the catalog to page 7
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 8

AIRCLEAN — Stringent standards Whisper quiet -Obtaining the lowest overall noise level involves selecting the best fan, the prime source of noise in an air handling unit. -The two walls of the panel are specially designed to absorb a maximum of noise. They are not connected and contain two different thicknesses (different natural frequencies). -Each anti-vibration mount is selected to reduce vibration and noise phenomena “at the source”. -The geometry of the sound attenuators is optimised to lower noise to the unit’s overall acoustic performance level. Cleaned air -High level of filtration...

Open the catalog to page 8
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 9

Controlled humidity STEAM HUMIDIFIER -Self-contained steam generator: -Uses electrodes or heating elements depending on the quality of the water supply. -The size and quality of the ducts are adapted to the steam generated. -Stainless steel overflow pan and separator. -Stainless steel ducts adapted to central steam generation systems. ADIABATIC HUMIDIFIER -Stainless steel enclosure and eliminator as standard. -UV water treatment systems may be integrated. Controlled environments Meets the following standards governing air handling in controlled environments: -NF S 90-351: Healthcare...

Open the catalog to page 9
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 10

Clean Concept centre R The Clean Concept Research and Development Centre tests and validates the performance of the units in our thermal, aerodynamic, acoustic and indoor air quality testing facilities. Noise level optimisation - Resources: echo and anechoic chambers. - Optimisation of AIRCLEAN panels by testing sound insulation. Aerodynamic efficiency - Fans tested in accordance with ISO 5801 (Industrial fans — Performance testing using standardised airways). - The aerodynamic and acoustic characteristics of fans are validated before being added to CIAT’s ranges. Energy savings - Mixing...

Open the catalog to page 10
AIRCLEAN - AIRCLEAN SANTE - NA0307B - 11

R&I It is associated with EUROVENT and a number of other international certification programmes. Minimum leakage - Damper air tightness qualified in accordance with EN 1751 (Ventilation for buildings – Air terminal devices – Aerodynamic testing of dampers and valves) - Leakage classes 0 to 4: our standard dampers carry a class 3 rating (< 30 l/s/m2 at 1000 Pa), class 4 dampers (< 6 l/s/m2 at 1000 Pa) are available as an option. - Leaks through the blades and the frame are taken into account. Innovation - Development and validation of innovative integrated molecular filtration systems (VOCs,...

Open the catalog to page 11