NoiseReducer™ - 1

Specification Sheet SPOT: PMS 300 & PMS 425 NoiseReducer™ Sound Attenuation and Acoustical Ceiling Batts PRODUCT DESCRIPTION Basic Use: These products are designed for use in commercial and residential wall and ceiling assemblies to effectively reduce transmission of airborne sound and provide thermal insulation. Product Name NoiseReducer™ Sound Attenuation and Acoustical Ceiling Batts CertainTeed Corporation Benefits: They provide excellent acoustical performance to help reduce sound transmission between adjoining rooms. These lightweight, flexible products are easy to handle and fabricate on the job site and conform to irregular surfaces. The product resists mold and mildew and will not rot or deteriorate. Composition and Materials: The product is composed of tan, uniformly textured, inorganic fibrous glass and formed with a formaldehyde-free binding agent. Sound Attenuation Batts are available unfaced for friction fit installation between studs or Kraft faced for easy positive attachment to interior wood stud framing. Acoustical Ceiling Batts are available unfaced and Kraft faced (without stapling tabs) for installation on suspended ceilings. Limitations: The National Electrical Code prohibits installation of any insulation over or within 3" (76 mm) of recessed light fixtures, unless approved insulated ceiling (IC) lighting fixtures are used. Standard Kraft facing is flammable and should not be left exposed. Kraft faced insulation must be installed behind and in substantial contact with the unexposed surface of the ceiling, floor or wall finish. Special care should be taken when working with an open flame. Where a flame spread rating of 25 is required, insulation must be unfaced or have flame-resistant foil facing (FSK-25). Because of potential skin irritation, unfaced building insulation should not be installed in an exposed application where it will be subject to human contact. All building insulation should be kept dry. Wet fiber glass insulation will lose its effectiveness until it dries. Fiber glass will often dry naturally and regain its original R-Value. However, under conditions where the insulation will not dry thoroughly, it should be removed and replaced. Sizes: Available standard sizes are listed in table on other side. Contact CertainTeed for non-standard sizes. INSTALLATION For most areas, vapor retarders should be installed on the warm-in-winter side of the insulation (toward the interior). Check local practice and/or building codes. CertainTeed insulation is not intended to be installed with the facing placed toward the exterior of the building. Requirements for installation: • nfaced Sound Attenuation Batts – Friction fit between steel studs. (Supplementary support may be U required for floor/ceiling installations.) • coustical Ceiling Batts – Lay faced or unfaced batts directly on suspended ceilings. (Check with A ceiling panel manufacturer for weight limitations.) • nterior Wall (white) Kraft Faced Batts – Staple flanges to either the faces or sides of studs or joists I using enough staples to prevent gaps. Do not leave the facing exposed; see limitations above. TECHNICAL DATA Applicable Standards • Model Building Codes: – ICC – alifornia and Minnesota C Quality Standards • Material Standards: – ASTM C553, Type I, II – ASTM C665, Type I, unfaced – STM C665, Type II, Class C, Category 1, kraft faced A • REENGUARD® Children & Schools Certified G Fire Resistance • Fire Hazard Classification: – ASTM E84 Unfaced insulation: Max. Flame Spread Index: 25 Max Smoke Developed Index: 50 Kraft faced insulation: Not rated for flame spread/smoke developed • oncombustibility: ASTM E136 N Unfaced insulation / Pass Physical/Chemical Properties • Thermal Performance: – STM C 518 / R-values for insulation only, as stated A in table on other side. • Water Vapor Sorption: – ASTM C1104 / < 5% • Water Vapor Permeance: – Permeance of Kraft Facing: ASTM E96, Desiccant method < 1.0 perm (57 ng/Pa•s•m2) – Class II vapor retarder Quality Assurance CertainTeed’s commitment to quality and environmental management has ensured the registration of the Athens, Chowchilla and Kansas

Open the catalog to page 1
NoiseReducer™ - 2

www.certainteed.com/insulation Sound ATTENUATION Batts AVAILABILITY AND COST For availability and cost, contact your local contractor or distributor, or call CertainTeed Sales Support Group at 800-233-8990. Available sizes R-Value TECHNICAL SERVICES Technical assistance can be obtained either from the local CertainTeed sales representative, or by calling CertainTeed Sales Support Group in Valley Forge, PA at 800-233-8990. WARRANTY Refer to CertainTeed’s Lifetime Limited Warranty for Fiber Glass Building Insulation (30-21-1321). Samples of this product are tested periodically by the NAHB...

Open the catalog to page 2

All Certain Teed catalogs and technical brochures

  1. EverNew®

    28 Pages

  2. Monogram ™

    3 Pages

  3. GrandManor

    12 Pages

Archived catalogs

  1. GlasRoc

    24 Pages

  2. ADAGIO

    2 Pages