The document details various tile sizes along with their coverage percentages per square meter, indicating the proportion each tile size contributes in mixed-format layouts. Examples include 24.8x99.8 cm, 16.4x99.8 cm, and 9.7x59.5 cm tiles covering 100% per square meter, while larger tiles like 29.6x59.5 cm, 60x60 cm, and 30x60 cm have coverage ratios ranging from 33% to 75% depending on the series.
Recommended tile size combinations are provided to achieve balanced and aesthetically pleasing surfaces. Notable combinations include:
The standard grout joint width is 2 mm for rectified tile modules. For natural porcelain stoneware tiles, a wider grout joint of 3-4 mm is recommended due to slight dimensional variations. Installation without grout joints (butt joint) is strongly discouraged. Instead, a staggered laying pattern with tiles offset by 10-20% is advised to improve visual appeal and accommodate size differences.
Effective surface planning must account for:
Natural porcelain stoneware tiles have minor size irregularities, necessitating grout joints to ensure proper installation and aesthetics.
Installation planning must consider mechanical, temperature, physical, and chemical stresses, room size, surface slopes, tile type, installation method, joint sizes, expansion joints, and perimeter expansions.
Tile selection should evaluate technical requirements, available formats, intended use, and grout color. Bright or contrasting grout colors may complicate cleaning. Natural porcelain stoneware tiles require installation gaps of 2 mm for rectified tiles and 3-4 mm for natural tiles. Seamless installation is discouraged; a deck-style layout with 10-20% offset is recommended.
Before installation, lay out 2-3 square meters of tiles from multiple boxes to assess color harmony. Tiles should not be soaked or marked. Installers must report visible defects to client and designer and obtain approval before proceeding. Installation should ideally start with client and designer present. Tiles must be kept clean and protected from contamination or damage by other trades during and after installation.
Final inspection involves unaided visual examination from about 1 meter. Defects visible only under bright light, close inspection, or magnification are not considered defects. Claims for visible defects before installation are not accepted post-installation. Supplier responsibility covers material quality only, not installation quality. Retaining spare tiles is essential for repairs or dispute resolution.
The document is provided in multiple languages including Italian, English, French, German, Spanish, and Russian to ensure accessibility for international users.
Fuga minima consigliata 2mm Recommended joint width 2mm Joint conseille pour le module 2mm Empfohlene Fugenbreite fuf das Modul 2mm Junta minima aconsejada 2mm MmnManbHbih peKOMeHgyeMbih Bbi
Open the catalog to page 4PROGETTO DELLE SUPERFICI Per valorizzare un pavimento e rivestimento ASCOT, consentendo la massima espressione delle sue qualita estetiche e tecniche, e necessario tenere conto di quei fattori che influenzano la posa in opera, come la destinazione d'uso dell'am-biente, i carichi, le sollecitazioni meccaniche, termiche, fisiche e chimiche alle quali le piastrelle saranno sottoposte, le dimensioni dell'ambiente e le eventuali pendenze. Di conseguenza, il capitolato dovra comprendere ogni specifica del cantiere: tipo e modalita di posa, dimensione della fuga, eventuali giunti di dilatazione, giunti...
Open the catalog to page 5Indications for laying - Indications pour la pose Hinweise zur verlegung - Indicaciones para la colocacion - MHopy^MM no yKnagKe PLANNING FOR SURFACES To get the most from ASCOT floor and wall cladding, allowing the maximum expression of its aesthetic and technical qualities, it is necessary to take into account the factors that influence the installation, such as the intended use of the environment, the loads, the mechanical, thermal, physical and chemical stresses to which the tiles will be subjected, the dimensions of the environment and any slopes present. Consequently, the specifications must...
Open the catalog to page 6OBERFLACHENPROJEKT Fur die optimale Aufwertung eines FuBbodens oder einer Wandverkleidung ASCOT und damit ihrer asthetischen und technischen Qualitat, mussen bestimmte Faktoren bei der Verlegung berucksichtigt werden. Dazu gehoren die beabsichtigte Nutzung der Umgebung, die Belastungen, sowie die mechanischen, thermischen, physikalischen und chemischen Spannungen, denen die Fliesen ausgesetzt werden und nicht zuletzt die Abmessungen der Umgebung und eventuelle Neigungen. Dementsprechend muss die Leistungsbeschreibung jede Spezifikation der Baustelle enthalten: Art und Weise der Verlegung, Abmessung...
Open the catalog to page 7Indicazioni per la posa Indications for laying - Indications pour la pose Hinweise zur verlegung - Indicaciones para la colocación - Инструкции по укладке ПРОЕКТИРОВАНИЕ ПОВЕРХНОСТЕЙ Чтобы оценить напольную и облицовочную плитку компании ASCOT с максимальным выражением ее эстетического и технического качества, необходимо учитывать факторы, влияющие на укладку в общем, такие как место назначения, нагрузки, механические, температурные, физические и химические, которым подвергнется плитка, размер помещения и потенциальный наклон поверхностей. Следовательно, план работ должен включать каждую особенность...
Open the catalog to page 8444 Pages
2 Pages