1. Catalogs
  2. Centor
  3. Centor hardware maintenance
video corpo

Centor hardware maintenance

Centor hardware maintenance

Product catalog summary
Contact Information
Centor provides contact details for its North America, Europe, and Australia offices, including phone numbers and email addresses. The company's website is also listed for further information.
Maintenance Overview
Centor emphasizes the importance of proper installation and maintenance of its products to ensure longevity and uphold warranty terms. Products must be installed according to good trade practices and maintained as per the provided guidelines.
Automatic Closures and Operators
Centor hardware systems are designed for manual operation. Automatic operator closers can cause damage and are not covered under warranty.
Environmental Considerations
Hardware is susceptible to deterioration from use and environmental conditions, especially in coastal and industrial areas. Even stainless steel requires maintenance to prevent corrosion.
Maintenance Procedures
  • Track and Bearings: Apply white petroleum jelly to tracks and bearings to reduce wear and protect against corrosion. Clean with a damp cloth and mild detergent, and apply a corrosion preventative in severe environments.
  • Hangers, Pivots, and Brackets: Use a corrosion preventative spray, wipe with a dry cloth, and clean with warm soapy water before application.
  • Hinges: Clean with soapy water and apply a light machine oil or corrosion preventative spray to maintain metal finish.
  • Dropbolts: Lubricate the sliding pin and lock cylinder with a suitable spray, using access holes for application.
Maintenance Frequency
Maintenance should be performed regularly to prevent deterioration. Recommended frequency is every six months for general environments and every three months for marine and industrial environments. Regular maintenance is crucial to maintain warranty validity.
See more

Catalog excerpts

Centor hardware maintenance-1

All products must be installed in accordance with accepted good trade practice (and in accordance with supplied instructions where applicable), and maintained in accordance with these procedures or else the warranty shall be void. Automatic closures and operators All Centor hardware systems are designed for manual operation. Poorly adjusted automatic operator closers can impart significant destructive forces to tracks, bearings and stops. Such hardware used in installations is expressly excluded from Centor warranty terms. Hardware in buildings is subject to deterioration from everyday use, and also from environmental attack due to atmospheric and other conditions. Maintenance of hardware is even more important in severe environments such as coastal marine areas, and some industrial areas. Even stainless steel products require maintenance to prevent deterioration in some environments. Centor requires the following minimum maintenance to be followed otherwise the warranty shall be void. Track and bearings Using a spatula or similar (not your finger), apply a small amount (typically a 1/4 teaspoon) of white petroleum jelly (Vaseline) or similar lubricant to the inner lip of each side of the track. Ensure that the wheels pass through the lubricant and it is distributed evenly along the track. Put additional lubricant around bearings. Lubricant reduces wear, improves smoothness and further protects against corrosion of track and bearings. Remove all surface contaminants by wiping all visible track surfaces with a damp soft cloth and a mild detergent, then wipe clean with a clean cloth. In severe environments, apply a thin film of a corrosion preventative such as CRC Marine 66, Innox or WD40, by wiping with a soft cloth moistened with one of these products. Stainless-steel bearings are manufactured from hardening-grade stainless-steel and although this material performs considerably better than plated steels, it is still susceptible to corrosion unless maintained as described above. Hangers, pivots and brackets A light spray application of a corrosion preventative such as CRC Marine 66®, Innox® or WD40®, followed by a light wipe with a dry cloth to remove excess, is recommended to all hangers, pivots and brackets. Exposed surfaces should first be wiped down with warm soapy water and a soft rag, and then rinsed clean before applying preventative. Hinges Wipe down the visible surfaces with warm soapy water on a soft rag and then rinse off by wiping with a clean damp rag. Application of a thin film of a light machine oil or one of the corrosion preventative sprays mentioned above will help to maintain the original lustre of the metal finish. Be careful not to get these compounds on the timberwork itself as they may cause staining. Dropbolts Spray application of a suitable lubricant such as CRC Marine 66®, Innox® or WD40® to the sliding pin inside the bolt and to the lock cylinder is recommended. A tube attached to the nozzle will help to concentrate the spray where you want it to go. There are access holes or slots on all dropbolt products so that this can be done without removing the locks from the doors. Frequency The procedures mentioned above need to be carried out as often as is necessary to prevent deterioration in the installed environment, however we recommend the following minimum frequency of application: general environments 6 monthly marine and industrial environments 3 monthly Regular maintenance is required to all hardware, even stainless steel, otherwise the manufacturer's warranty may be voided. Centor North America + 1 630-957-1000 [email protected]

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.