video corpo

CELEGON - Ergon Living TE - Technical Manual EN-rev11
34Pages

{{requestButtons}}

Catalog excerpts

CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 1

TECHNICAL MANUAL - CONSTRUCTION AND INSTALLATION swinging sliding door with connecting rod on frame JAMB THICKNESS 50 mm CELEGON S.r.l. - Via G. Galilei, 6 - 30035 Mirano (Venezia) - T +39 (0)41 5728404 - F +39 (0)41 5728522 www.ergon.eu - info@ergon.eu MTC ERGONTE ITA - Rev. 11-04/2018

Open the catalog to page 1
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 2

HC6L6GON SMART OPENING SYSTEMS INDEX

Open the catalog to page 2
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 4

HC6L6GON SMART OPENING SYSTEMS INTRODUCTION Ergon T.E. version extend the possibilities of use ERGON® technology for internal residential doors, which are built for doors unsuitable to contain the connecting rod between the two arms, such as glass, mirror, solid wood doors, etc. To guarantee the reliability and practicality provided by thousands of produced models, the components used for the T.E. version come from ERGON® LIVING S40 and ERGON® COMMUNITY models. These models are certified by the research institute and test laboratory CATAS according to EN 1119 standards and they passed...

Open the catalog to page 4
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 5

HC6L6GON SMART OPENING SYSTEMS FRAME SPECIFICATIONLOCK ERGON LIVING double way of opening. ERGON System double opening way doors permit the use of two different types of latch/lock mechanisms, each with its own functional characteristics: - Magnetic latch. This type of latch was designed for traditional doors that open one way only. If used with a double opening way, it does not work well unless the door is moved by hand to the closed position. If the door is pushed, even lightly, the magnetic latch is not activated and the door continues its swing past the closed position. - "Mediana...

Open the catalog to page 5
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 6

HC6L6GON SMART OPENING SYSTEMS SINGLE DOOR HORIZONTAL DIMENSIONAL DRAWING recommended to reduce the gap to 3 mm on this side only. CAUTION: On doors with reduced widths the handle may collide with the jamb Pay attention to the dimensions of the' handle, door and wall thickness. = DOOR JAMB OPENING ( LFM = OUTER JAMB ( LFM - 24 ) = FIXED DIMENSION ENCUMBRANCE ARM-SIDE = VARIABLE Dl MENSION ENCUMBRANCE HANDLE-SIDE = Available standard dimensions = Several examples of dimensions that can be obtained by shortening the track. Intermediate dimensions are also possible. For other custom...

Open the catalog to page 6
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 7

SMART OPENING SYSTEMS _ERGON LIVING T.E. DOUBLE DOOR HORIZONTAL DIMENSIONAL DRAWING (ERGON DOOR LEAF AND RABBET DOOR)(dimensional example) The door can be positioned at the centre The values shown in the above diagram refer to a door with frame thickness 50 mm and door thickness 45 mm. When ordering hardware, the dimensions of the wall opening and the type of arm that will be used must be provided. A custom track kit will be supplied based on the dimensions provided. LEGEND LFMD = WALL HOLE WIDTH LPD = PASSAGE DIMENSION ( LFMD - 210 ) LAI = DOOR LEAF WIDTH (see teble on page 5) LA2 =...

Open the catalog to page 7
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 8

SMART OPENING SYSTEMS ERGON LIVING T.E.DOUBLE DOOR HORIZONTAL DIMENSIONAL DRAWING (DOUBLE ERGON DOOR LEAVES) (dimensional example) If a magnetic lock is used, it is recommended to reduce the gap between door leafs to 3 mm. The values shown in the above diagram refer to a door with frame thickness 50 mm and door thickness 45 mm. In this case, it is possible to use track kits for single doors in combination with the dedicated union kit. For specifications, see pages 19-20-21. The door can be positioned at the centre with respect to the thickness of the wall. centered door See page 10 for...

Open the catalog to page 8
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 9

HC6L6GON SMART OPENING SYSTEMS DIMENSIONAL VERTICAL DRAWING VERTICAL DIMENSION HFM wall hole height Available standard dimensions; it is possible to have other dimensions, even intermediate dimensions, by adjusting the doorpost (see page 17) and the connecting rod (see page 18). For getting rods in special sizes, kindly contact Celegon s.r.l..

Open the catalog to page 9
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 10

HC6L6GON SMART OPENING SYSTEMS MANAGING WALL THICKNESSThe particular translation movement causes the door to retreat during opening, meaning wall thickness requires special attention to prevent the door from colliding with the surface of the jamb (see drawing below). To increase the wall thickness, the jamb thickness can be reduced <40 mm. By reducing the jamb to less than 40 mm, the wall thickness can be increased by approximately 30 mm for every 2 mm (e.g. jamb thickness 38 mm = BASE arm wall thickness 290 mm). If rounded jambs are used, the above thickness wall dimension must be...

Open the catalog to page 10
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 12

HC6L6GON SMART OPENING SYSTEMS EXPLODED VIEW OF THE FRAME 12

Open the catalog to page 12
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 13

SMART OPENING SYSTEMS DETAILS FOR VERTICAL FRAME ARM SIDE HP = HEIGHT PASSAGE DIMENSION---VISIBLE SIDE

Open the catalog to page 13
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 14

HC6L6GON SMART OPENING SYSTEMS DETAILS FOR VERTICAL FRAME LOCK SIDE DOORPOST DIMENSION THAT MUST BE x = WALL THICKNESS - 45 ACCURATE HP = HEIGHT PASSAGE DIMENSION---VISIBLE SIDE ORIENTED DOOR CENTERED DOORWhen the door is in the middle of the wall, you must have two specular jambs -1

Open the catalog to page 14
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 15

HC6L6GON SMART OPENING SYSTEMS DETAILS FOR THE UPPER CROSSBEAM ,1 j Wall Hole Width - 24 mm DIMENSION THAT MUST BE ACCURATE --VISIBLE SIDE

Open the catalog to page 15
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 16

HC6L6GON SMART OPENING SYSTEMS TRACK ADJUSTMENTTO THE WIDTH OF THE DOOR LFM WALL HOLE WIDTH track cover caps

Open the catalog to page 16
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 18

HC6L6GON SMART OPENING SYSTEMS CUTTING OF THE CONNECTING ROD FOR NOT STANDARD HEIGHTS. _ERGON LIVING T.E.

Open the catalog to page 18
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 19

Part list item number 564000 A traditional lever latch system can be used or the Push&Go Evo magnetic system (recommended, see pg. 21) N.B.: for the limits of the wall thickness see page 10 in this manual. LFM minimum 1600 mm. with BASE arm, with "Soft Opening" LFM minimum 1700 mm. LFM minimum 1400 mm. with SMALL arm, with "Soft Opening" LFM minimum 1500 mm. LFM minimum 2300 mm. with LARGE arm, with "Soft Opening" LFM minimum 2300 mm. For dimensions smaller than those indicated, contact Celegon S.r.l.

Open the catalog to page 19
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 20

SMART OPENING SYSTEMS ERGON LIVING T.E.KIT UNION TRACKS FOR DOOR WITH TWO DOOR LEAVES WITH ERGON LIVING SYSTEM 20

Open the catalog to page 20
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 21

HC6L6GON SMART OPENING SYSTEMS Silver item number 4150IA Black item number 4150IN ref.

Open the catalog to page 21
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 22

HC6L6GON SMART OPENING SYSTEMS ASSEMBLING THE HARDWARE IN THE DOOR LEAF Parts list

Open the catalog to page 22
CELEGON - Ergon Living TE - Technical Manual EN-rev11 - 23

HC6L6GON SMART OPENING SYSTEMS ASSEMBLING CONNECTING ROD WITH UPPER AND LOWER ARM Install the upper and lower arms into the rod which is already inside the aluminium profile and mind the alignment, when you insert the brasses be careful to the kingpins on the bearing brasses: they must be inserted in the screws' hexagons. Attention! Tighten firmly the screws (205) with a hexagonal spanner 2,5 mm. Make sure that the arm adheres to the pin plate of the connecting rod.

Open the catalog to page 23

All Celegon catalogs and technical brochures