Product catalog summary
Overview: The T-56 Space Temperature Sensor with Override and Setpoint Adjustment is designed to enhance interior decor while offering advantages over conventional thermostats, such as eliminating drift and calibration, reducing maintenance costs, and providing accurate temperature sensing.
Package Contents: The package includes one space temperature sensor, two 6-32" x 1" round head machine screws, and installation instructions.
Features: The sensor includes an override button and a temperature offset slide for controlling connected device features. The override button allows tenants to request an override of the HVAC occupancy schedule, while the temperature slide switch enables occupants to adjust heating and cooling setpoints.
Connectivity: The sensor requires a twisted, three-conductor, shielded cable connection to the CCN controller. It also features a communication port for a CCN Network Service Tool, requiring an additional three-conductor shielded cable.
Applications: Typically used with CCN Comfort Controller or ComfortID Zone Controller for temperature sensing, remote timed override, and setpoint bias. Base setpoints are set by CCN ComfortVIEW or ComfortWORKS operators. The Tenant Billing Option tracks after-hours usage initiated by the sensor.
Specifications:
  • Connections: Labeled screw terminals
  • Operating Temperature: 32°F to 120°F (0°C to 49°C)
  • Storage Temperature: -40°F to 160°F (-40°C to 70°C)
  • Humidity: 0% to 95%, non-condensing
  • Dimensions: 4.51 in H x 2.75 in W x 1.15 in D (11.46 cm x 6.98 cm x 2.92 cm)
  • Color: Beige
Thermistor Specifications:
  • Zero Power Resistance: 10K Ohms @ 25°C
  • Tolerance: +/- 0.2°C from 0 to 70°C
  • Dissipation Constant: 3 mWatt/°C
  • Thermal Time Constant: 10 seconds (for 63.2% step change)
Setpoint Adjustment Specifications:
  • Cool: 0 Ohms (nominal)
  • Center: 50K Ohms (nominal)
  • Heat: 100K Ohms (nominal)
See more

Catalog excerpts

T-56 SPACE TEMPERATURE SENSOR WITH OVERRIDE AND SETPOINT ADJUSTMENT-1

PRODUCT DATA T-56 SPACE TEMPERATURE SENSOR WITH OVERRIDE AND SETPOINT ADJUSTMENT The T-56 Space Temperature Sensor with Override and Setpoint Adjustment is designed to complement any interior decor. The sensor has the following advantages over conventional thermostats: • Elimination of drift and calibration • Reduced maintenance cost • Accurate temperature sensing The T-56 Space Temperature Sensor package consists of: • (1) Space Temperature Sensor • (2) 6-32" x 1" round head machine screws • (1) Installation Instructions Bus. Use of the communication port for the Network Service Tool requires an additional three-conductor shielded cable. The sensor's override button and temperature offset slide are provided for the control of features in the device to which the sensor is connected. The corresponding features must be present and enabled in the device to which the sensor is connected in order for the button and/or slide to have any effect. The sensor's integral override button allows a tenant to signal a request for an override of the occupancy schedule currently controlling the HVAC equipment in that zone. The sensor's integral temperature slide switch allows an occupant to adjust (bias) the heating and cooling setpoints upward and downward by a configured amount. To support its temperature sensing, override, and setpoint adjustment functions, the sensor must be connected by a twisted, three-conductor, shielded cable to the CCN controller that it serves. SENSOR APPLICATIONS The wall sensor is used typically with the CCN Comfort Controller or ComfortID Zone Controller for temperature sensing, remote timed override and setpoint bias. Base setpoints for cooling and heating are set by the CCN ComfortVIEW or ComfortWORKS operator. When used with CCN controllers that support timed override, the T-56 Space Temperature Sensor provides the following: • Electronic measurement of space temperature • Occupancy override by pushing the override button The Tenant Billing Option can be used in conjunction with the CCN controllers to keep track of timed overrides initiated with the T-56 Space Temperature Sensor. Tenant Billing tracks a tenant's after-hours usage of a CCN system. The sensor also includes a communication port for connection of a CCN Network Service Tool. A Network Service Tool connected to that port can communicate with all system elements on the CCN Communication Specifications subject to change without notice

 Open the catalog to page 1
T-56 SPACE TEMPERATURE SENSOR WITH OVERRIDE AND SETPOINT ADJUSTMENT-2

Specifications subject to change without notice

 Open the catalog to page 2

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32  Pages

  2. 42B-6SI

    24  Pages

  3. 19DV

    32  Pages

  4. 30XA

    136  Pages

  5. 30RAP

    104  Pages

Archived catalogs

  1. Carrier VRF

    44  Pages

  2. ComfortVIEW 3

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.