Special Seismic Compliance
1Pages

{{requestButtons}}

Catalog excerpts

Special Seismic Compliance - 1

turn to the experts Hospitals, schools, governments, emergency shelters, public places, etc. across the country are being required to comply with special seismic requirements. This seismic requirement includes the equipment in the building, not just the structure to achieve special seismic certification. WHAT CHANGED? Previously, manufacturers would provide calculations as proof that equipment would maintain operation after a seismic event. Newer codes require equipment must be tested on a "shake table" in a lab. WHAT AGENCY OR CODE REGULATES THIS TESTING? ICC Evaluation Service, Inc., a non-profit organization has developed a test plan known as AC156 — Acceptance Criteria for Special Seismic Qualification by Shake Table Testing of Nonstructural Components & System which is acceptable to IBC, UBC and other local building code governing agencies. Carrier's water-cooled chillers (19XR(V), 23XRV, 30HX and 30MP) and air-cooled chillers (30XA, 30RB, 30RAP) and split systems (38AP/09DP), product families are special seismic compliant. FEATURES -• Products tested on a shake table, simulating seismic effects as per AC-156 requirements as required by ICC Evaluation Service, Inc. • Certificate of Compliance or OSHPD pre-approval documentations are available at the time of specification and submittals • Seismic kit is provided along with the equipment for ground or roof installation • Consultant and Owner know that the equipment was certified for seismic events by an independent third party HOW CAN I GUARANTEE THAT THE EQUIPMENT MEETS AC-156 SEISMIC QUALIFICATION? YOU CAN SPECIFY THE FOLLOWING: • Manufacturer shall provide pre-approved documentation from OSHPD • Manufacturer shall provide seismic certificate of compliance • Manufacturer shall have performed seismic testing (shake table test) of specified model family as per ICC-ES AC-156 by recognized/ accredited third party approving agency For your next project requiring special seismic certification, contact your local Carrier sales engineer for more information. SEISM ICOM PLIANT *Meets IBC 2006, ASCE-7-05, CBC 2007 and OSHPD seismic requirements. AquaEdge® 19XR(V) Two-Stage Water-Cooled Centrifugal Chillers AquaEdge® 19XR(V) Single-Stage Water-Cooled Centrifugal Chillers AquaEdge® 23XRV Water-Cooled Screw Chillers AquaForce® 30HX Water-Cooled Screw Chillers AquaSnap® 30MP Water-Cooled Scroll Chillers © Carrier Corporation 2017 04-811-50040 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs, without notice and without incurring obligations. AquaForce® 30XA Air-Cooled Screw Chillers AquaSnap® 30RB Air-Cooled Scroll Chillers AquaSnap® 30RAP Air-Cooled Scroll Chillers AquaForce® 30XA Air-Cooled Screw Chillers with Greenspeed® Intelligence AquaSnap® 30RB Air-Cooled Scroll Chillers with Greenspeed® Intelligence Gemini® Select 38AP / 09DP Split Systems

Open the catalog to page 1

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32 Pages

  2. 42B-6SI

    24 Pages

  3. 19DV

    32 Pages

  4. 30XA

    136 Pages

  5. 30RAP

    104 Pages

  6. Carrier VRF

    44 Pages

Archived catalogs