Special Seismic Compliance Brochure
1Pages

{{requestButtons}}

Catalog excerpts

Special Seismic Compliance Brochure - 1

What Does HVAC Equipment Have To Do with Earthquakes or Special Seismic Compliance? Hospitals, schools, governments, emergency shelters, public places, etc. across the country are being required to comply with special seismic requirements. This seismic requirement includes the equipment in the building, not just the structure to achieve special seismic certification. SEISMICALLY CERTIFIED PRODUCTS (Water-Cooled Chillers) WHAT CHANGED? Previously, manufacturers would provide calculations as proof that equipment would maintain operation after a seismic event. Newer codes require equipment must be tested on a “shake table” in a lab. WHAT AGENCY OR CODE REGULATES THIS TESTING? ICC Evaluation Service, Inc., a non-profit organization has developed a test plan known as AC156 – Acceptance Criteria for Special Seismic Qualification by Shake Table Testing of Nonstructural Components and Systems which is acceptable to IBC, UBC and other local building code governing agencies. FEATURES • Products tested on a shake table, simulating seismic effects as per AC-156 requirements as required by ICC Evaluation Service, Inc. • Certificate of Compliance or HCAI pre-approval documents are available at the time of specification and submittals • Seismic kit is provided along with the equipment for ground or roof installation • Consultant and owner know that the equipment was certified for seismic events by an independent third party HOW CAN I GUARANTEE THAT THE EQUIPMENT MEETS AC-156 SEISMIC QUALIFICATION? You can specify the following: • Manufacturer shall provide pre-approved documentation from OSHPD • Manufacturer shall provide seismic certificate of compliance • Manufacturer shall have performed seismic testing (shake table test) of specified model family as per ICC-ES AC-156 by recognized/accredited third party approving agency AquaEdge® 19XR(V) OSP-0026-101 TwoStage Water-Cooled Centrifugal Chillers1 AquaEdge® 19DV OSP-0797 WaterCooled Centrifugal Chillers AquaEdge® 19XR(V) OSP-0026-10 SingleStage Water-Cooled Centrifugal Chillers1 AquaEdge® 23XRV OSP-0406-10 WaterCooled Screw Chillers1 AquaForce® 30HX OSP-0161-10 WaterCooled Screw Chillers AquaSnap® 30MP OSP-0184-101 WaterCooled Scroll Chillers1 SEISMICALLY CERTIFIED PRODUCTS (Air-Cooled Chillers and Split Systems) ^ AquaSnap® 30RAP OSP-0184-10 30RAP Air-Cooled Scroll Chillers with or without Greenspeed Intelligence AquaForce® 30XV OSP-0184-10 AirCooled Screw Chillers Gemini® 09DP OSP-0184-10 38AP / Split Systems For your next project requiring special seismic certification, contact your local Carrier expert for more information. *Meets IBC 2006, ASCE-7-05, CBC 2007 and HCAI seismic requirements. Carrier’s water-cooled chillers (19XR(V), 19DV, 23XRV, 30HX and 30MP), air-cooled chillers (30RAP, 30XV) and split systems (38AP/09DP) product families are special seismic compliant. ©2024 Carrier. All Rights Reserved. Cat. No. 04-811-50040 All trademarks and service marks referred herein are property of their respective owners. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs, without notice and without incurring obligations. Certain models only at this time. OSP stands for HCAI Special Seismic Certification Pre‑appr

Open the catalog to page 1

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32 Pages

  2. 42B-6SI

    24 Pages

  3. 19DV

    32 Pages

  4. 30XA

    136 Pages

  5. 30RAP

    104 Pages

  6. Carrier VRF

    44 Pages

Archived catalogs