  3. Single Direct Drive Plenum Fans in Carrier’s Aero® 39M Air Handlers
video corpo
cad

Single Direct Drive Plenum Fans in Carrier’s Aero® 39M Air Handlers

Single Direct Drive Plenum Fans in Carrier’s Aero® 39M Air Handlers

Single Direct Drive Plenum Fans in Carrier’s Aero® 39M Air Handlers

Product catalog summary
Overview: The Carrier 39M Air Handlers feature single direct drive plenum fans available in sizes 03 to 61, offering three fan wheel diameters. These fans eliminate belt losses typical in belt-driven fans, reducing maintenance and eliminating belt residue in the airstream.
Benefits of Direct Drive Plenum Fans: Direct drive plenum fans provide the advantages of plenum fans without the belt losses (3-5%) associated with belt-driven fans. Maintenance is minimal due to the absence of belts and sheaves.
Fan Wheel Diameter Options: The 39M offers a variety of fan wheel diameters to optimize fan solutions based on specific airflow conditions and desired fan operation. The choice of diameter is crucial for maximizing efficiency, especially in Variable Air Volume (VAV) systems that operate mostly at partial load.
Efficiency Considerations: - For systems operating near 50% load (e.g., Chicago), the smallest fan wheel (18.2 inches) is most efficient.
- For climates like Houston, where operation is around 70-80% of design load, the 20-inch wheel is optimal.
- For constant volume systems operating at full load, the 22.2-inch wheel provides the best efficiency.
VAV System Modeling: Carrier's 39M selection software allows for accurate modeling of VAV fan performance, ensuring adequate airflow to all zone terminals by maintaining minimum duct static pressure. The software provides fan curves with a VAV system curve to model fan performance accurately.
Conclusion: The Carrier 39M air handler offers a comprehensive range of fan wheel options and the capability to model VAV fan operation effectively, providing an optimal direct drive plenum fan solution.
See more

Catalog excerpts

Single Direct Drive Plenum Fans in Carrier’s Aero® 39M Air Handlers-1

Single Direct Drive Plenum Fans Single direct drive plenum fans are available in Carrier’s 39M air handler sizes 03 to 61 with 3 fan wheel diameters available in most sizes. Why choose direct drive plenum fans? Direct drive plenum fans provide all of the benefits of plenum fans while eliminating the belt losses that belt driven plenum fans carry (typically 3-5%). With no belts or sheaves, routine maintenance on a direct drive plenum fan is minimal compared to its belt driven counterpart, and belt residue in the airstream is eliminated. The 39M’s large breadth of fan wheel options provides the optimal fan solution What fan wheel diameter is optimal? While this depends on the specific airflow conditions as well as the desired fan operation, having many fan wheel diameters to choose from will give you the best solution. Fans in a VAV system will spend the majority of their operation at partial load. The exact percentage of airflow where that partial load is, however, will differ from region to region and even job to job. Figure 1 shows a comparison of a typical VAV fan operation in Houston and Chicago. As can be seen, operation in Houston spends significant time above 80% of design conditions, while an operation in a climate similar to Chicago spends minimal time above 50%. Figure 1: Percentage of Design Load Operation in Houston and Chicago The best way to see the benefits of a large breadth of fan wheel offerings is with a specific example. Figure 2 (next page) shows the 3 different direct drive plenum fan wheel options for a 39M air handler size 12, selected at 6,000 cfm with a minimum expected airflow of 3,000 cfm (shown as the MP on the fan curves) and a minimum static pressure of 1.5 inches. Since VAV systems operate at partial load the majority of the time, a VAV fan should be chosen to maximize efficiency while the fan is operating at partial load. To accomplish this, the operation at partial load should be as close to the maximum static efficiency (MSE) line as possible. For those systems that will spend the majority of their time at or near 50% load (for example, Chicago) the smallest fan wheel diameter (18.2 inches) has the highest efficiency. For a climate similar to Houston, where the majority of the operation may be spent around 70-80% of design load, the 20 inch wheel provides the best efficiency. The 22.2 inch wheel provides the best efficiency for those systems expected to operate only at full load (constant volume system).

 Open the catalog to page 1
Single Direct Drive Plenum Fans in Carrier’s Aero® 39M Air Handlers-2

Figure 2: Direct Drive Plenum Fan Wheel Diameter Options Smallest wheel — best for VAV application, with highest efficiency at partial load Medium wheel — best for VAV application, with minimal fan turn down, with highest efficiency at ~75% load. Largest wheel — best for CV application, with highest efficiency at full load. Carrier’s 39M selection software can provide the ability to properly model VAV fan performance In a VAV system, the duct static pressure sensor will maintain a minimum duct static pressure to ensure adequate airflow to all zone terminals. This minimum duct static pressure...

 Open the catalog to page 2

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32  Pages

  2. 42B-6SI

    24  Pages

  3. 19DV

    32  Pages

  4. 30XA

    136  Pages

  5. 30RAP

    104  Pages

Archived catalogs

  1. Carrier VRF

    44  Pages

  2. ComfortVIEW 3

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.