1. Catalogs
  2. CARRIER commercial
  3. ROOMTOP® 50AH024-096 Horizontal Indoor
video corpo
cad

ROOMTOP® 50AH024-096 Horizontal Indoor

ROOMTOP® 50AH024-096 Horizontal Indoor
1 / 24 PagesView full catalog

ROOMTOP® 50AH024-096 Horizontal Indoor

Product catalog summary
Overview: The Carrier 50AH single-package cooling units are designed for high efficiency and flexibility, featuring ASHRAE 90.1 certification, scroll compressor technology, and the use of Puron refrigerant (R-410A). These units are compact, easy to maintain, and offer quiet operation, making them suitable for various commercial applications.
Key Features:
  • Design and Installation: The units are designed for easy installation with a compact form that fits within ceiling spaces. They can be configured as package or split systems, with options for water or air-cooled units.
  • Efficiency and Operation: Equipped with scroll compressors for high efficiency and low noise, these units use Puron refrigerant, which is environmentally friendly with no ozone depletion potential.
  • Maintenance and Reliability: The units offer easy access for maintenance with side panels and are factory-tested for reliability, featuring safety controls to protect the system over its lifespan.
Technical Specifications:
  • Capacity Ratings: Units range from 2 to 8 nominal tons, with various configurations for different voltage and phase requirements.
  • Physical Data: The units include copper tube and aluminum fin coils, centrifugal belt-drive fans, and cleanable indoor-air filters. They are designed with specific dimensions and weights for different models.
  • Options and Accessories: Factory-installed options include hot gas bypass, hot gas reheat, and air-side economizers. Field-installed accessories include electric duct heaters, thermostats, and condensate pumps.
Performance and Controls: The units are designed to operate efficiently under various conditions, with options for upgraded motors for higher external static pressure. Controls include thermostatic expansion valves and high/low pressure switches for safety and performance optimization.
Specifications: The document provides detailed specifications for Carrier's indoor packaged units, specifically models 50AH024-060 and 50AH072-096. These units are designed for horizontal cooling applications and utilize hermetic scroll compressors. They are certified according to ARI standards and are ETL listed.
Electrical Data: The document includes electrical data for various models, specifying voltage, amperage, and other electrical characteristics. It also defines terms such as FLA (Full Load Amps), LRA (Locked Rotor Amps), and MOCP (Maximum Overcurrent Protection).
Wiring and Piping: Wiring schematics and piping instructions are provided, emphasizing compliance with local and national codes. The document outlines the requirements for factory and field wiring, including the use of American Wire Gage (AWG) standards.
Installation Instructions: Instructions for field splitting and unit configuration are detailed, including guidelines for refrigerant tubing and condenser mounting. The document stresses the importance of minimizing condenser air recirculation and ensuring proper installation to prevent issues such as coil freezing.
Unit Features: The units are constructed with heavy-duty galvanized steel and insulated with fiberglass. They include features such as stainless steel drain pans, removable access panels, and junction boxes for power connections. The document also describes the fan and compressor specifications, including the use of forward-curved, centrifugal blowers and hermetic scroll compressors.
Control and Safety Features: The control system includes high and low-pressure switches, a compressor lockout feature, and options for hot gas bypass and reheat. The document also mentions the use of a freezestat device to protect coils from freezing.
Optional Features: Several optional features are available, such as airside economizers, hot gas bypass, hot gas reheat, freeze protection switches, and externally mounted condensate pumps. The document provides specifications for these features and their applications.
Quality Assurance and Handling: The units are factory-tested for performance and shipped fully assembled with R-410A refrigerant. Handling and storage instructions are provided to ensure proper maintenance and operation.
Conclusion: The document concludes with a disclaimer that specifications and designs are subject to change without notice, emphasizing the manufacturer's right to make modifications.
See more

Catalog excerpts

ROOMTOP® 50AH024-096 Horizontal Indoor-1

Product Data ROOMTOP® 50AH024-096 Horizontal Indoor Single-Package Cooling Units with PURON® Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: • ASHRAE 90.1 certification • scroll compressor technology • compact and flexible design • Puron refrigerant (R-410A) • easy maintenance • high quality and reliability • quiet and efficient scroll compressor technology • water or air-cooled units availability • belt-drive motors Features/Benefits All in one package — high cooling efficiency, installation convenience, ease of accessibility allow for timesaving maintenance. Space and cost saving design The Roomtop 50AH unit is specifically designed to provide building owners with a versatile horizontal air conditioning system that can be adapted to many cooling applications. The flexible design and low silhouette enable it to fit easily and securely within the ceiling above the conditioned space. Singlepackage construction makes it easy to install with minimal time and cost. Copyright 2009 Carrier Corporation Form 50AH-8PD

 Open the catalog to page 1
ROOMTOP® 50AH024-096 Horizontal Indoor-2

Features/Benefits (cont) Application flexibility If desired for particular applications, the unit can also be installed as a package or split system with the condenser section mounted horizontally. Centrifugal fans permit ducting of both evaporator and condenser air. Quiet operation Commercial end users appreciate the extra comfort of quiet operation. Carrier engineers met the challenge by specifying heavy insulation, vibrationresistant construction and operating components that function at low noise levels, all of which keep system sound at a minimum level. Easy maintenance When it comes to...

 Open the catalog to page 2
ROOMTOP® 50AH024-096 Horizontal Indoor-3

Model number nomenclature 50AH AC 048 5 – – – – 2 1 XX FIOP* 50AH – Horizontal, Indoor Single-Package Cooling Unit Packaging 1 – Domestic 2 – Export, Crated 3 – Export, Non-Crated Compressor Options AC – Air Cooled WC – Water Cooled Design Changes 2 – R-410A Original Design 3 – R-410A Special Unit Size - Nominal Tons 024 – 2 060 – 5 036 – 3 072 – 6 048 – 4 096 – 8 Economizer and Hot Gas Options – – None A – Hot Gas Bypass† B – Hot Gas Reheat† C – Air-Side Economizer with Controls D – Hot Gas Bypass and Hot Gas Reheat† E – Hot Gas Bypass and Air-Side Economizer† F – Hot Gas Bypass, Air-Side Economizer,...

 Open the catalog to page 3
ROOMTOP® 50AH024-096 Horizontal Indoor-4

Physical data UNIT 50AH OPERATING WEIGHT (lb) Base Unit Evaporator/Condenser Sections SHIPPING WEIGHT (lb)* REFRIGERANT TYPE Operating Charge (lb-oz)† COMPRESSOR — TYPE Quantity...Model Oil (oz) HPS Setting (psig) Cutout Reset LPS Setting (psig) Cutout Reset CONDENSATE DRAIN CONNECTION Size (in.)...Type CONDENSER COIL Size (L x H) (in.) Number of Rows...Fins/in. CONDENSER FAN Nominal Cfm Blower Size (in.) Motor Hp Motor Rpm EVAPORATOR COIL Size (L x H) (in.) Number of Rows...Fins/in. EVAPORATOR AIR FAN Nominal Cfm Blower Size (in.) Motor Hp (Rpm) INDOOR-AIR FILTERS Number...Size (in.) INTERCONNECTING...

 Open the catalog to page 4
ROOMTOP® 50AH024-096 Horizontal Indoor-5

UNIT 50AH OPERATING WEIGHT (lb) Base Unit Evaporator/Condenser Sections SHIPPING WEIGHT (lb)* REFRIGERANT TYPE Operating Charge (lb-oz)† COMPRESSOR — TYPE Quantity...Model Oil (oz) HPS Setting (psig) Cutout Reset LPS Setting (psig) Cutout Reset CONDENSATE DRAIN CONNECTION Size (in.)...Type CONDENSER COIL Size (L x H) (in.) Number of Rows...Fins/in. CONDENSER FAN Nominal Cfm Blower Size (in.) Motor Hp Motor Rpm EVAPORATOR COIL Size (L x H) (in.) Number of Rows...Fins/in. EVAPORATOR AIR FAN Nominal Cfm Blower Size (in.) Motor Hp (Rpm) INDOOR-AIR FILTERS Number...Size (in.) INTERCONNECTING TUBING...

 Open the catalog to page 5
ROOMTOP® 50AH024-096 Horizontal Indoor-6

Options and accessories ITEM Hot Gas Bypass Hot Gas Reheat Air Side Economizer Freezestat High-Static Motor Upgrade Flooded Condenser Electric Duct Heaters Thermostats Disconnect Externally Mounted Condensate Pump Factory-installed options Hot gas bypass — Hot gas bypass is available for extended capacity operation and to prevent coil freezing at low load conditions. Hot gas reheat — When indoor air quality is a concern, a hot gas reheat coil can be ordered to help control humidity levels. Normally, bringing humidity levels down to acceptable levels requires cooling the air to relatively low...

 Open the catalog to page 6
ROOMTOP® 50AH024-096 Horizontal Indoor-7

AIR OUT 16 1/8 B 111 111 116 117 CLEARANCE HOLE FOR 3/8" HANGING ROD TYP 8 PLS REAR 64 1/2 DETAIL A A 87 87 91 91 NOTE: Dimensions are in inches. 6 1/8 18 3/4 1 3/4 024 036 048 060 UNIT 50AH 2 28 3 13/16 1 1/2 H G AIR IN 33 COMPRESSOR ACCESS 48 DETAIL "A" COND SECTION 44 1/8 WEIGHT OF CORNER (lb) C D E F 88 113 143 136 89 114 144 138 92 118 152 145 93 119 153 146 LEFT TOP F A E B 42 D C 24 60 FRONT RETURN AIR 34 3/4 36 IN. SERVICE CLEARANCE 1 3/8 3 3/4 3 1/2 62 1 15/16 CONDENSATE DRAIN 7/8" OD COIL ACCESS FILTER ACCESS EVAP SECTION 38 1/8 H 100 101 106 107 QUICK CONNECT ACCESS G 105 106 111 112...

 Open the catalog to page 7
ROOMTOP® 50AH024-096 Horizontal Indoor-9

REAR 75 ELECTRICAL CONNECTIONS TYP MOTOR ACC B 128 129 COMPRESSOR ACCESS 2 29 6 H G DETAIL "A" AIR IN 53 65 COND SECTION 61 1/8 LEFT TOP F A E B 3 7/8 WEIGHT OF CORNER (lb) C D E F 149 152 126 128 149 153 139 142 1 1/2 NOTE: Dimensions are in inches. ELECT BOX ACCESS A 125 126 CLEARANCE HOLE FOR 3/8" HANGING ROD TYP 8 PLS DETAIL A 072 096 UNIT 50AH OPERATING WEIGHT DISTRIBUTION FILTER ACCESS C D H 192 212 CONDENSATE DRAIN 7/8" OD COIL ACCESS 47 EVAP SECTION 43 1/8 G 188 208 4 11/16 25 1 1/4 3 1/2 72 1/2 1 15/16 RETURN AIR 39 FRONT 70 1/2 36 IN. SERVICE CLEARANCE STANDARD UNIT SUPPLY AIR 16 1/16...

 Open the catalog to page 9
ROOMTOP® 50AH024-096 Horizontal Indoor-11

Selection procedure (with example) I Determine cooling requirements at design conditions. Given: Gross Cooling Capacity Required (TC) . . . . . . . . . . . . . . . . . .36,000 Btuh Sensible Heat Capacity (SHC) . . . . . .27,000 Btuh Temperature of Air Entering Condenser . . . . .95 F Temperature of Air Entering Evaporator . . . . . . . . . . . . . 80 F edb/67 F ewb Evaporator Air Quantity. . . . . . . . . . . . 1,200 cfm External Static Pressure: Condenser . . . . . . . . . . . . . . . . . . .0.50 in. wg Evaporator (includes static pressure drop of factory-supplied filter of 0.06 in. wg) . ....

 Open the catalog to page 11

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32  Pages

  2. 42B-6SI

    24  Pages

  3. 19DV

    32  Pages

  4. 30XA

    136  Pages

  5. 30RAP

    104  Pages

Archived catalogs

  1. Carrier VRF

    44  Pages

  2. ComfortVIEW 3

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.