Catalog excerpts
Product Data OMNIZONE™ 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units offer: • Water-cooled models available in nominal 5 to 20-ton capacities, remote air-cooled models available in nominal 5 to 15-ton capacities • Compact, durable, and attractive cabinet fits any working environment • Ducted or free-blow applications • High-efficiency cooling for commercial and industrial projects • Ideal solution for spot cooling applications Features/Benefits The Omnizone 50BRN,BZN units are efficient and selfcontained for today’s cooling needs. Application versatility The 50BRN (water-cooled) and 50BZN (condenserless) systems are available in 6 convenient sizes, ranging from 60,000 to 240,000 Btuh (50BRN), to ideally meet the needs for cooling restaurants, retail stores, warehouses, offices, and building additions. These units can be installed in an equipment room or the conditioned space and specified for either ducted applications or free-blow applications with an accessory plenum. Copyright 2008 Carrier Corporation Form 50B-4PD
Open the catalog to page 1Features/Benefits (cont) Easy installation and maintenance The units are completely prepiped and wired at the factory to assure time and money-saving installation and service. Interior access panels are easily removed to provide speedy inspection and service of internal components and controls, and all service work may be done from the front of the unit. Precision engineered parts translate to a quality built, reliable design that will operate efficiently, minimize service calls, and provide years of reliable operation. • • Designed for customer satisfaction Where space and styling are...
Open the catalog to page 2COMPONENTS CONTROL CIRCUIT BREAKER (HIDDEN) THERMOSTATIC EXPANSION VALVE LOW-VOLTAGE TERMINAL BLOCK (HIDDEN) LOW-VOLTAGE CONTROL SECTION CONTROL RELAY HIGH-SIDE SERVICE CONNECTION HIGH-VOLTAGE TERMINAL BLOCK HIGH-PRESSURE SWITCH COMPRESSOR LOCKOUT LOW-PRESSURE SWITCH LOW-PRESSURE CONNECTION FILTER DRIER COMPRESSOR BRAZED PLATE HEAT EXCHANGER 50BRN UNIT SHOWN Model number nomenclature a50-8254.eps 3
Open the catalog to page 3ARI* capacity ratings UNIT 50BRN006 50BRN008 50BRN012 50BRN014 50BRN016 50BRN024 50BZN006/09BY006 50BZN008/09BY008 50BZN012/09BY012 50BZN014/09BY014 50BZN016/09DE016 EER LEGEND — Energy Efficiency Ratio *Air Conditioning and Refrigeration Institute. 4 CAPACITY (Btuh) 58,000 78,000 115,000 133,000 145,000 224,000 59,000 83,700 123,000 131,000 161,000 EER 12.2 12.5 12.5 11.6 10.7 12.0 9.1 9.4 9.0 9.3 9.4 ASHRAE 90.1 COMPLIANT Yes Yes Yes Yes No Yes No No No No No NOTE: Rated in accordance with ARI Standard 360-2001. Ratings are net values, reflecting the effects of circulating fan heat....
Open the catalog to page 4Physical data (cont) 50BZN UNIT SIZE 50BZN NOMINAL CAPACITY (TONS) OPERATING WEIGHT (lb) Base Unit Plenum COMPRESSOR Model Quantity Rpm Oil Charge (oz) Steps of Control OPERATING CHARGE† No. of Circuits...Charge per ckt HOLDING CHARGE** Nitrogen INDOOR FAN Nominal Cfm Cfm Range Fan Size (in.) Number of Fans Standard Speed Range (Rpm) Max Allowable Rpm Motor Rpm Belt Quantity...Type Fan Pulley (in.) Motor Pulley (in.) Nominal Hp...Frame Size Fan Shaft Size (mm) Motor Shaft Size (in.) Center Distance (in.) INDOOR COIL Number of Rows...Fin/in. Face Area (sq ft) RETURN AIR FILTERS...
Open the catalog to page 6Base unit dimensions 50BRN006-014 UNIT DIMENSIONS a50-8255.eps * *Not available with hot water coil. 7
Open the catalog to page 7Base unit dimensions (cont) 50BRN016,024 UNIT DIMENSIONS SPLITABLE a50-8256.eps NOTES: 1. Unit sizes 016 and 024 do not include return grilles. 2. Only size 024 units are splitable. Fan section can be rotated in the field per diagram. 8
Open the catalog to page 850BZN006-014 UNIT DIMENSIONS 5/8” OD DISCHARGE LINE 5/8” OD LIQUID LINE 9
Open the catalog to page 9Accessory dimensions HOT WATER COIL 50BRN,BZN012,014 50BRN,BZN006,008 45.91 [1166.0] 46.14 [1172.0] 50BRN,BZN016 NOTE: Dimensions in [ 50BRN024 ] are in millimeters. 11
Open the catalog to page 11Accessory dimensions (cont) STEAM COIL 50BRN,BZN006,008 50BRN,BZN016 NOTE: Dimensions in [ 12 ] are in millimeters. 50BRN,BZN012,014 50BRN024
Open the catalog to page 12Electrical data (cont) 09BY CONDENSER ELECTRICAL DATA 09BY UNIT SIZE 006 008 012 014 016 V-Ph-Hz 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 OUTDOOR FAN MOTOR Hp FLA 5.8 2.0 2.6 2.1 8.6 3.0 3.9 3.1 14.2 5.0 6.4 5.1 14.2 5.0 6.4 5.1 14.2 5.0 6.4 5.1 LEGEND FLA — Full Load Amps MCA — Minimum Circuit Amps MOCP — Maximum Overcurrent Protective Device (see Note) *Minimum circuit amps and MOCP amps values per NEC (see Note). †Maximum overcurrent protective device for 208/230-v units and...
Open the catalog to page 30Typical wiring schematics 50BRN,BZN006,008 UNITS LEGEND C CB CLO CR EQUIP FSW GND HPS IFC IFM IFP LPS NEC TB TDR TRAN — — — — — — — — — — — — — — — — Compressor Contactor Circuit Breaker Compressor Lockout Control Relay Equipment Fan Switch Ground High-Pressure Switch Indoor-Fan Contactor Indoor-Fan Motor Indoor-Fan Protector Low-Pressure Switch National Electrical Code Terminal Block Time Delay Relay Transformer Terminal Box Connection Marked Terminal Unmarked Terminal Splice Factory Wiring Field Wiring NOTES: 1. Fan motors are inherently thermally protected. 2. Three-phase motors are...
Open the catalog to page 31Typical wiring schematics (cont) 50BRN,BZN12,014 UNITS LEGEND C CB CLO CR EQUIP FSW GND HPS IFC IFM IFP LPS NEC TB TDR TRAN — — — — — — — — — — — — — — — — Compressor Contactor Circuit Breaker Compressor Lockout Control Relay Equipment Fan Switch Ground High-Pressure Switch Indoor-Fan Contactor Indoor-Fan Motor Indoor-Fan Protector Low-Pressure Switch National Electrical Code Terminal Block Time Delay Relay Transformer Terminal Box Connection Marked Terminal Unmarked Terminal Splice Factory Wiring Field Wiring a50-8258.eps 32 NOTES: 1. Fan motors are inherently thermally protected. 2....
Open the catalog to page 32All CARRIER commercial catalogs and technical brochures
-
40UV-UH-14SI
32 Pages
-
42B-6SI
24 Pages
-
A WORLD OF COMFORT PRINT
10 Pages
-
A WORLD OF COMFORT
20 Pages
-
AirStream™ Room Fan Coils
4 Pages
-
The CRRSA Act (ESSER I)
2 Pages
-
A World of Comfort
2 Pages
-
Carrier-Catalogue-2018-2019
940 Pages
-
Axis™ Overhead Air Terminals
4 Pages
-
AERO® Air-Handling Units
4 Pages
-
19DV
32 Pages
-
30XA
136 Pages
-
30RAP
104 Pages
-
2019 Carrier Ductless
88 Pages
-
Carrier VRF
44 Pages
-
Special Seismic Compliance
1 Pages
-
Axis Overhead Air Terminals
2 Pages
-
Roomtop® 50AH036-072
24 Pages
-
OMNIZONE™ 50BV020-064
64 Pages
-
A World of Comfort
2 Pages
-
Low Noise Type CABINET FAN
16 Pages
-
Performance 16 Heat Pump
4 Pages
-
ComfortVIEW 3
6 Pages
-
VVT Zoning System
8 Pages
-
Heat Reclaim Chillers
2 Pages
-
Airstream Unit Ventilators
2 Pages
-
Airstream Room Fan Coils
2 Pages
-
Aero Air-Handling Units
2 Pages
-
17DA Centrifugal Chiller
2 Pages
-
AXIS? Overhead Air Terminals
3 Pages
-
Comfort? Series
2 Pages
-
GEMINI? 38AKS028-044
40 Pages
-
i-Vu Open Standard & Plus
2 Pages
Archived catalogs
-
ROOMAIR CONDITIONERS
6 Pages
-
AIRSTREAM™ Room Fan Coils
3 Pages
-
Water-Cooled Chillers
3 Pages
-
Antimicrobial Solutions
3 Pages