STAGED AIR VOLUME SAV™ SYSTEM The new Carrier® Staged Air Volume SAV™ System saves energy and installation time by utilizing a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed in sequence with the units cooling, heating and ventilation operation. Comfort Control • ompared to single speed indoor fan motor systems, C can save 25%+ in energy to help reduce operating costs. • mproves unit Integrated Energy Efficiency Ratio (IEER). I • ay qualify for utility rebates. M • elps lower indoor humidity level at lower speed by improving H air over coil efficiencies. • ndoor fan speed is matched to cooling staging for better load I profile control and occupant comfort. Code Compliant Simple Set-Up and Operation • omplies with ASHRAE 90.1 2010 standard for Single Zone C Variable Air Volume (SZ-VAV) control. • eets requirement for California Title 24 indoor fan M speed control. • arrier exceeds ASHRAE 90.1 2010 standard by offering the C SAV™ System on popular 7.5 and 8.5 ton models. • re programmed VFD allows simple fan pulley adjustments P to establish fan performance settings. • o special training or certified start up is required. N Operating Sequence • re programmed, tested and installed at the factory. P • oft start capability eliminates high in-rush air volume S to help reduce noise in duct systems during speed change. • rovides indoor fan motor over current protection. P Unit Designed Indoor Fan CFM (%) Energy Savings* 1st Stage Full All Cooling Cooling Heat Unit Operation (Stage) * See back page for more information Vent Only
Open the catalog to page 1STAGED AIR VOLUME SAV™ SYSTEM Models Available with the SAV™ System Model Series 48/50TC&Q (2 stage cooling models only) Operating Savings with the SAV™ System Compared to single speed indoor fan motor systems, Carrier’s staged air volume SAV™ System utilizing variable frequency drive (VFD) and 2-speed indoor fan motor can save substantial energy.* STAGED AIR VOLUME % Energy Savings ($)* 60% * nnual estimated electric energy savings utilizing Carrier’s Hourly Analysis (HAP) Program v4.6. Based on cooling and ventilation fan runtime hours using ASHRAE 90.1 office A application, default schedule,...
Open the catalog to page 232 Pages
24 Pages
10 Pages
20 Pages
4 Pages
32 Pages
136 Pages
104 Pages
2 Pages
4 Pages
4 Pages
940 Pages
88 Pages
44 Pages
2 Pages
24 Pages
64 Pages
2 Pages
16 Pages
4 Pages
6 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
40 Pages
2 Pages
2 Pages
3 Pages
6 Pages
3 Pages
3 Pages