1. Catalogs
  2. CARRIER commercial
  3. New Carrier® Staged Air Volume SAV? System Brochure 18-811-053
video corpo
cad

New Carrier® Staged Air Volume SAV? System Brochure 18-811-053

New Carrier® Staged Air Volume SAV? System Brochure 18-811-053

New Carrier® Staged Air Volume SAV? System Brochure 18-811-053

Product catalog summary
Overview of the Carrier Staged Air Volume SAV™ System
The Carrier Staged Air Volume (SAV™) System is designed to enhance energy efficiency and reduce installation time by using a Variable Frequency Drive (VFD) to adjust the indoor fan motor speed in coordination with cooling, heating, and ventilation operations.
Energy Savings
  • The system can save over 25% in energy compared to single-speed indoor fan motor systems, reducing operating costs.
  • It improves the Integrated Energy Efficiency Ratio (IEER) and may qualify for utility rebates.
Code Compliance
  • Complies with ASHRAE 90.1 2010 standard for Single Zone Variable Air Volume (SZ-VAV) control.
  • Meets California Title 24 requirements for indoor fan speed control.
  • Available on popular 7.5 and 8.5-ton models, exceeding ASHRAE 90.1 2010 standards.
VFD Benefits
  • Pre-programmed, tested, and installed at the factory.
  • Soft start capability reduces noise in duct systems during speed changes.
  • Provides overcurrent protection for the indoor fan motor.
Comfort Control
  • Lowers indoor humidity levels at lower speeds by improving air over coil efficiencies.
  • Matches indoor fan speed to cooling stages for better load profile control and occupant comfort.
Simple Set-Up and Operation
  • Pre-programmed VFD allows for simple fan pulley adjustments to set fan performance.
  • No special training or certified start-up is required.
Operating Savings
The SAV™ System, using VFD and a 2-speed indoor fan motor, offers substantial energy savings compared to single-speed systems, with varying savings across different cities such as Miami, Los Angeles, Phoenix, New York, St. Louis, and Atlanta.
Models Available
  • Model Series: 48/50TC&Q (2 stage cooling models only), 48/50HC&Q, 40RUA&Q, 40RUS
  • Sizes range from 7.5 to 30 tons depending on the model series.
See more

Catalog excerpts

New Carrier® Staged Air Volume SAV? System Brochure 18-811-053-1

STAGED AIR VOLUME SAV™ SYSTEM The new Carrier® Staged Air Volume SAV™ System saves energy and installation time by utilizing a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed in sequence with the units cooling, heating and ventilation operation. Comfort Control • ompared to single speed indoor fan motor systems, C can save 25%+ in energy to help reduce operating costs. • mproves unit Integrated Energy Efficiency Ratio (IEER). I • ay qualify for utility rebates. M • elps lower indoor humidity level at lower speed by improving H air over coil efficiencies. • ndoor fan speed is matched to cooling staging for better load I profile control and occupant comfort. Code Compliant Simple Set-Up and Operation • omplies with ASHRAE 90.1 2010 standard for Single Zone C Variable Air Volume (SZ-VAV) control. • eets requirement for California Title 24 indoor fan M speed control. • arrier exceeds ASHRAE 90.1 2010 standard by offering the C SAV™ System on popular 7.5 and 8.5 ton models. • re programmed VFD allows simple fan pulley adjustments P to establish fan performance settings. • o special training or certified start up is required. N Operating Sequence • re programmed, tested and installed at the factory. P • oft start capability eliminates high in-rush air volume S to help reduce noise in duct systems during speed change. • rovides indoor fan motor over current protection. P Unit Designed Indoor Fan CFM (%) Energy Savings* 1st Stage Full All Cooling Cooling Heat Unit Operation (Stage) * See back page for more information Vent Only

 Open the catalog to page 1
New Carrier® Staged Air Volume SAV? System Brochure 18-811-053-2

STAGED AIR VOLUME SAV™ SYSTEM Models Available with the SAV™ System Model Series 48/50TC&Q (2 stage cooling models only) Operating Savings with the SAV™ System Compared to single speed indoor fan motor systems, Carrier’s staged air volume SAV™ System utilizing variable frequency drive (VFD) and 2-speed indoor fan motor can save substantial energy.* STAGED AIR VOLUME % Energy Savings ($)* 60% * nnual estimated electric energy savings utilizing Carrier’s Hourly Analysis (HAP) Program v4.6. Based on cooling and ventilation fan runtime hours using ASHRAE 90.1 office A application, default schedule,...

 Open the catalog to page 2

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32  Pages

  2. 42B-6SI

    24  Pages

  3. 19DV

    32  Pages

  4. 30XA

    136  Pages

  5. 30RAP

    104  Pages

Archived catalogs

  1. Carrier VRF

    44  Pages

  2. ComfortVIEW 3

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.