Product catalog summary
Overview: The document provides comprehensive information on Carrier's 38AP Series commercial air-cooled condensing units, designed for compatibility with Carrier's 40RU or 39 Series indoor-air handlers. These units emphasize efficiency, reliability, and adaptability in commercial cooling solutions.
Specifications: The 38AP units comply with ASHRAE 90.1 standards and utilize Puron refrigerant (R-410A), which is environmentally friendly. They feature Novation® heat exchangers with microchannel coil technology and are available in single and dual circuit configurations, supporting up to 6 rotary scroll compressors.
Features and Benefits: These units offer high Energy Efficiency Ratios (EERs) up to 11.5 and Integrated Part Load Values (IPLVs) up to 16.2. They are certified to UL and CSA standards and are ETL approved, with durable, weather-resistant cabinets made of galvanized steel.
Versatility and Reliability: The 38AP Series can be paired with various air-handling units and offer digital scroll compressors for precise load matching. Safety features include short-cycle protection, low superheat protection, and high refrigerant pressure switches.
Installation and Service: Designed for ease of installation and service, the units feature hinged control-box access doors and ComfortLink controls for straightforward monitoring and control. The Navigator™ display assists technicians in diagnosing and preventing issues.
Options and Accessories: The document details options for packaging, controls, ambient/capacity control, line length, electrical configurations, and sound treatment, along with model number nomenclature for easy specification identification.
Performance Data: Extensive performance data is provided, including capacity ratings, operating weights, refrigerant charges, and compressor specifications, with tables for capacity steps and fan configurations.
Conclusion: Carrier's 38AP Series condensing units provide a robust solution for commercial cooling needs, focusing on efficiency, reliability, and adaptability to various building requirements.
Condensing Unit Ratings Overview: Detailed performance data for various condensing units operating at 60 Hz SI is provided, including ratings for models like 38APD070, 38APD080, and others, based on R-410A refrigerant and an 8.3°C superheat.
Key Specifications: The document specifies the use of R-410A refrigerant and a 15 F superheat for all ratings, accounting for suction line losses due to an accumulator.
Performance Data: Tables show Gross Cooling Capacity (TC) and Compressor Power (kW) across various Saturated Suction Temperatures (SST) and Condenser Entering-Air Temperatures, organized by model and circuit.
Data Interpretation: Cooling capacity decreases as condenser entering-air temperature increases, while compressor power consumption rises, indicating more energy is required to maintain cooling output.
Recommendations: For detailed system design and optimization, refer to the Commercial Split Builder program.
Electrical Specifications: Detailed electrical specifications include supply voltage, compressor and condenser fan details, and key electrical parameters such as Full Load Amps (FLA), Locked Rotor Amps (LRA), Minimum Circuit Amps (MCA), and Maximum Overcurrent Protection (MOCP).
Microprocessor Control: The ComfortLink microprocessor manages unit operations, supporting communication with Carrier Comfort Network (CCN) and other protocols like BACnet, MODBUS, and LonWorks.
Cooling Control Options: Various cooling control methods are outlined, including constant volume (CV) and variable air volume (VAV) with multiple stages of cooling.
Diagnostics and Interface: ComfortLink controls integrate sensors and routines for advanced diagnostics, including compressor protection and low refrigerant charge protection.
Installation Guidelines: Guidelines emphasize compliance with local codes, ensuring sufficient space for airflow and service, and securing units properly.
Refrigerant Piping Requirements: Specifications for refrigerant piping, including pipe sizes and lengths based on unit size and configuration, are provided.
Quality Assurance: Units are rated according to AHRI Standard 365 and comply with ASHRAE 15, UL 1995, and ASME codes, manufactured in ISO 9001 certified facilities.
Special Features: Options include low ambient control, E-coated MCHX condenser coils, sound reduction features, digital compressor options, and various communication and display options.
See more

Catalog excerpts

GEMINI? SELECT 38APS025-065, 38APD025-130-1

Product Data GEMINI™ SELECT 38APS025-065, 38APD025-130 Commercial Air-Cooled Condensing Units with PURON® Refrigerant (R-410A) 50/60 Hz 25 to 130 Nominal Tons (88 to 457 Nominal kW) a38-7096 025 UNIT WITH LOW SOUND OPTION A38-7097 040-060 UNIT A38-7095 070 UNIT These dependable split systems match Carrier's 40RU or 39 Series indoor-air handlers with the versatile outdoor 38AP condensing units for a wide selection of commercial cooling solutions. • Split condensing units compatible with ASHRAE 90.1 • Chlorine-free, non-ozone depleting Puron refrigerant (R-410A) • Condenser coils feature the Novation® heat exchanger with microchannel coil technology • 38APS single-circuit unit has up to 3 rotary scroll compressors • 38APD unit has up to 6 rotary scroll compressors with 2 independent circuits • Standard scroll compressor units operate as low as 33% (single circuit) or 13% (dual circuit) of nominal capacity • Optional digital scroll compressors allow incremental unloading down to 16% (single circuit) or 6% (dual circuit) of nominal capacity for VAV applications. The digital scroll is always on the lead circuit (one per unit). • Protection against high discharge and low suction refrigerant pressure, and low oil pressure Features/Benefits The 38AP condensing unit offers the utmost in system configuration and control adaptability. Its premiumquality standard components ensure durable, efficient, and reliable operation. The 38AP units offer high unit EERs (Energy Efficiency Ratios) up to 11.5 and IPLVs (integrated part load values) up to 16.2. Copyright 2012 Carrier Corporation Form 38AP-11PD

 Open the catalog to page 1
GEMINI? SELECT 38APS025-065, 38APD025-130-2

Features/Benefits (cont) These units provide greater efficiency than similar units in the marketplace, which translates into year-round operating savings. The latest safety standards for 38AP units are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards, ETL approved. Versatility The 38AP Series condensing units feature up to 6 compressors and 2 refrigerant circuits, and can be matched with a wide variety of air-handling units. Single circuit condensing units can operate with a single air handler. Dual circuit condensing units can operate with a single...

 Open the catalog to page 2
GEMINI? SELECT 38APS025-065, 38APD025-130-3

AEROACOUSTIC™ FAN vs. PROPELLER FAN 90 SOUND POWER [dB(A)] MODE Run Status Service Test Temperature Pressures Setpoints Alarm Status Inputs Outputs Configuration Time Clock ENTER ESCAPE Operating Modes a30-2187 Alarms 85 80 75 70 65 60 PENETRATES BUILDING STRUCTURE 55 50 25 SCROLLING MARQUEE DISPLAY 40 63 130 168 250 400 630 1080 1600 2400 4000 6300 8000 1/3 OCTAVE BAND CENTER FREQUENCY (Hz) AEROACOUSTIC FAN a30-3162 PROPELLER FAN AEROACOUSTIC FAN VS PROPELLER FAN Com fortL ink MOD E Alarm Run Status Servic e Tes t perat ures Pressu res Setpo ints Status Tem Inputs Outpu ts Config uration Clock...

 Open the catalog to page 3
GEMINI? SELECT 38APS025-065, 38APD025-130-4

Model number nomenclature 38AP D 025 38AP – Split System Condensing Unit Refrigeration Circuit Options* D – Dual Refrigeration Circuit S – Single Refrigeration Circuit Unit Size 025 060 027 065 030 070 040 080 050 090 100 115 130 Pow er Supply 1 – 575-3-60 2 – 380-3-60 5 – 280/230-3-60 6 – 460-3-60 9 – 380/415-3-50 Condenser Coil/Low Sound Options 4 – MCHX, No Sound Treatment 5 – E-coat, MCHX, No Sound Treatment C – MCHX, Low Sound Fan(s) D – E-coat MCHX, Low Sound Fan(s) H – MCHX, Low Sound Fan(s), Compressor Blankets J – E-coat MCHX, Low Sound Fan(s), Compressor Blankets Revision Level A –...

 Open the catalog to page 4
GEMINI? SELECT 38APS025-065, 38APD025-130-10

Options and accessories ITEM Condenser Coil/Low Sound Options E-Coated MCHX Low Sound Fan(s) Low Sound Compressor Blankets Vibration Isolation Pads Line Length Options Long Line Length Check Valve Ambient/Capacity Control/Interrupt Options Digital Compressor* High Short Circuit Current Rating Interrupt Motormaster V Low Ambient Control Electrical Options Dual Point Power (sizes 115 and 130 only) Non-Fused Disconnect Controls/Communications Options Navigator™ Display Remote Enhanced Display Touch Pilot™ Display EMM BACnet Communications BACnet Translator Control LON Translator Control Packaging/Security...

 Open the catalog to page 10
GEMINI? SELECT 38APS025-065, 38APD025-130-11

Non-fused disconnect includes factory-installed nonfused disconnect capability for power and control located at the unit. Packaging options include bottom skid with standard coil protection and bottom skid, top crate with bag. Standard coil protection is also included on all unit packaging. Energy management module (EMM) provides energy management capabilities to minimize condensing unit energy consumption. The EMM is also available as a fieldinstalled accessory. BACnet communications option provides factory installed communication capability with a BACnet MS/TP network. Allows integration with...

 Open the catalog to page 11
GEMINI? SELECT 38APS025-065, 38APD025-130-12

12 1077 (489) 1095 (497) 1240 (563) 1258 (571) 1246 (565) 1264 (573) 1113 (505) 1131 (513) 1276 (579) 1294 (587) 1282 (582) 1300 (590) STANDARD WEIGHT, lb (kg) CENTER OF GRAVITY, in. (mm) X Y 17.8 (452) 36.9 (937) 17.8 (452) 37.0 (940) 18.2 (462) 37.6 (955) 18.2 (462) 37.6 (955) 18.2 (462) 37.5 (953) 18.2 (462) 37.6 (955) 17.8 (452) 36.9 (937) 17.8 (452) 37.0 (940) 18.2 (462) 37.6 (955) 18.2 (462) 37.6 (955) 18.2 (462) 37.5 (953) 18.2 (462) 37.6 (955) 78.6 (1996) 66.5 (1689) 73.1 (1857) 61.0 (1549) HEIGHT, in. (mm) H a38-7223 H SEE NOTE #6 8.52 [216.4 ] 24.56 [623.8 ] 21.06 [534.9 ] 15.31 [388.9...

 Open the catalog to page 12
GEMINI? SELECT 38APS025-065, 38APD025-130-13

UNIT CIRCUIT B COMPRESSOR ACCESS FRONT VIEW (DUAL CIRCUIT) CONTROL BOX HINGED ACCESS PANEL SIDE SEE NOTE #5 48 [1219] MIN. 42 [1067] MIN. 78.5 (1994) 73.0 (1854) HEIGHT, in. (mm) H H SEE NOTE #6 27.98 [710.7 ] RADIUS 20 [508] CONTROL BOX HINGED ACCESS CENTER OF GRAVITY, in. (mm) X Y 35.0 (869) 44.0 (1118) 33.7 (856) 44.1 (1120) 34.9 (886) 44.0 (1118) 33.4 (848) 44.1 (1120) 34.4 (874) 44.1 (1120) 35.0 (869) 44.0 (1118) 33.7 (856) 44.1 (1120) 34.9 (886) 44.0 (1118) 33.4 (848) 44.1 (1120) 34.4 (874) 44.1 (1120) FRONT VIEW (SINGLE CIRCUIT) COMPRESSOR ACCESS 1968 (893) 2094 (950) 1977 (897) 2120 (961)...

 Open the catalog to page 13

All CARRIER commercial catalogs and technical brochures

  1. 40UV-UH-14SI

    32  Pages

  2. 42B-6SI

    24  Pages

  3. 19DV

    32  Pages

  4. 30XA

    136  Pages

  5. 30RAP

    104  Pages

Archived catalogs

  1. Carrier VRF

    44  Pages

  2. ComfortVIEW 3

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.