16LJ Single-Effect, Low Temperature Hot Water Hermetic Absorption Liquid Chiller, 75 to 525 Nominal Tons
32Pages
Catalog excerpts
Product Data Carrier SAMYO 16LJ Single-Effect, Low Temperature Hot Water Hermetic Absorption Liquid Chiller 75 to 525 Nominal Tons Carrier-Sanyo's 16LJ single-effect hermetic absorption liquid chiller is an efficient and functional alternative to traditional electric driven chillers. The 16LJ absorption chiller uses low temperature hot water as its energy source; as it eliminates the need for high cost electricity, it may qualify for financial incentives as a gas cooling product. The 16LJ absorption chiller offers functional flexibility in a variety of installations: • no CFCs; environmentally sound • single stage design for simple, dependable operation • high reliability with few moving parts • nominal coefficient of performance (COP) of .70 • quiet, vibration-free operation • Direct Digital Controls (DDC) for optimum chiller performance Features/Benefits Single-effect absorption cycle provides efficient, economical water chilling with minimal use of electricity. Cost-effective cooling Alternative-energy chiller — The 16LJ chiller is a solution for building owners who want to avoid high operating costs associated with electric-driven chillers. Powered by low temperature hot water, the Carrier-Sanyo 16LJ absorption chiller reduces or eliminates electric demand and/or ratchet charges while allowing the owner to take advantage of gas cooling incentives when offered by local utility companies. Copyright 2005 Carrier Corporation
Open the catalog to page 1Features/Benefits (cont) Simple, reliable operation — The 16LJ chiller’s single generator provides one stage of solution reconcentration, which makes the 16LJ chiller one of the most basic cycles currently available. The 16LJ chiller’s simple design, in addition to its other quality features, equates to inherently high reliability. Few moving parts and simple, dependable operation reduce downtime, as well as service and maintenance costs. Exceptional efficiency — The 16LJ chiller offers full-load COPs of .70 at standard ARI (Air Conditioning and Refrigeration Institute) operating...
Open the catalog to page 2The Carrier-Sanyo microprocessor PID (proportional, integral, derivative) control system surpasses proportional only control systems by maintaining precise leaving chilled water temperature versus actual set point. The PID controls surpass proportional only controls in their ability to control the machine and narrow temperature variations. The 16LJ chiller control system also incorporates the ability to control the chilled water and cooling water pumps automatically. During shutdown these pumps are sequenced to ensure a complete dilution cycle, thus providing protection from solution...
Open the catalog to page 3corrosion, lithium bromide solution crystallization, and/or reduction of chiller capacity. The Carrier-Sanyo purge system protects against these potential hazards by operating continuously during machine operation. How the purge system operates — During chiller operation, any noncondensables that are present tend to accumulate in the absorber section, which operates at the lowest pressure internal to the machine. A slipstream of lithium bromide solution flows through an eductor from the absorbent pump discharge. This process creates suction, which draws the noncondensables from the...
Open the catalog to page 416LJ ABSORPTION CHILLER COOLING CYCLE Hot Water Condenser Cooling Water Generator Chilled Water Heat Exchanger Cooling Water
Open the catalog to page 5Unit Size - Nominal Tons LJ - Single Effect, Low Temperature Hot Water (1-Stage) ^ Options and accessories ITEM
Open the catalog to page 6Machine components CONDENSER GENERATOR HOT WATER INLET CHILLED WATER OUTLET EVAPORATOR CHILLED WATER INLET COOLING WATER INLET CONTROL PANEL HEAT EXCHANGER
Open the catalog to page 7Physical data UNIT 16LJ
Open the catalog to page 8indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. American National Standards Institute Chilled Water Cooling Water Hot Water Wire connection 1-3/8 in. hole
Open the catalog to page 9American National Standards Institute Chilled Water Cooling Water Hot Water indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. PURGE PUMP Dimensions (cont)
Open the catalog to page 10American National Standards Institute Chilled Water Cooling Water Hot Water indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. PURGE PUMP
Open the catalog to page 11American National Standards Institute Chilled Water Cooling Water Hot Water indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. Dimensions (cont)
Open the catalog to page 12American National Standards Institute Chilled Water Cooling Water Hot Water indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine.
Open the catalog to page 13All CARRIER commercial catalogs and technical brochures
-
40UV-UH-14SI
32 Pages
-
42B-6SI
24 Pages
-
A WORLD OF COMFORT PRINT
10 Pages
-
A WORLD OF COMFORT
20 Pages
-
AirStream™ Room Fan Coils
4 Pages
-
The CRRSA Act (ESSER I)
2 Pages
-
A World of Comfort
2 Pages
-
Carrier-Catalogue-2018-2019
940 Pages
-
Axis™ Overhead Air Terminals
4 Pages
-
AERO® Air-Handling Units
4 Pages
-
19DV
32 Pages
-
30XA
136 Pages
-
30RAP
104 Pages
-
2019 Carrier Ductless
88 Pages
-
Carrier VRF
44 Pages
-
Special Seismic Compliance
1 Pages
-
Axis Overhead Air Terminals
2 Pages
-
Roomtop® 50AH036-072
24 Pages
-
OMNIZONE™ 50BV020-064
64 Pages
-
A World of Comfort
2 Pages
-
Low Noise Type CABINET FAN
16 Pages
-
Performance 16 Heat Pump
4 Pages
-
ComfortVIEW 3
6 Pages
-
VVT Zoning System
8 Pages
-
Heat Reclaim Chillers
2 Pages
-
Airstream Unit Ventilators
2 Pages
-
Airstream Room Fan Coils
2 Pages
-
Aero Air-Handling Units
2 Pages
-
17DA Centrifugal Chiller
2 Pages
-
AXIS? Overhead Air Terminals
3 Pages
-
Comfort? Series
2 Pages
-
GEMINI? 38AKS028-044
40 Pages
-
i-Vu Open Standard & Plus
2 Pages
Archived catalogs
-
ROOMAIR CONDITIONERS
6 Pages
-
AIRSTREAM™ Room Fan Coils
3 Pages
-
Water-Cooled Chillers
3 Pages
-
Antimicrobial Solutions
3 Pages