ultimateSAM:+30U0032EN
4Pages

{{requestButtons}}

Catalog excerpts

ultimateSAM:+30U0032EN - 1

air humidification systems isothermal humidification energy-efficient steam dispersion system carel.com

Open the catalog to page 1
ultimateSAM:+30U0032EN - 2

Steam distributor for short non-wetting distances Significant energy savings by minimizing condensation and heat loss in the AHU/duct. Uses steam from a pressurized distribution system or from a humidifier. • precision, aseptic humidification, with a short not-wetting distance (even less than 0.5 m/1.6 ft); • suitable for steam flow-rates from 44 to 2447 lbs/hr and pressure from 0 to 58 psig. Short not-wetting distance Holes set out along the entire height of the upright pipes deliver steam uniformly, ensuring a very short non-wetting distance. Hygiene and materials ultimateSAM is made from...

Open the catalog to page 2
ultimateSAM:+30U0032EN - 3

Pipe insulation To achieve a very short not-wetting distance and ensure only dry steam is delivered into the AHU/duct, the uprights and pipes (AISI 304) have nozzles (Ryton - PPS) that take steam from the inside of the pipe, away from the wall where condensate may form. The uprights and pipes can be ordered with air-cushion insulation. An AISI 304 steel structure isolates the steam pipe from direct contact with the air in the AHU/ duct, thus achieving a 30% reduction in condensate formation. Condensate separator manifold for SA0* single pipe models On single pipe versions the manifold also...

Open the catalog to page 3
ultimateSAM:+30U0032EN - 4

Unit code type: B= bottom steam inlet T= top steam inlet 0= single pipe pipe insulation: I= with insulation N= without insulation (for single pipe SA0, only “I”) market: U= North America 0= other markets S A _ _ _ _ _ _ _ 0 width: A= 447 mm (18”) B= 599 mm (24”) ... R= 3031 mm (120”) (for single pipe SA0, size “A” to “L” only) pipe type: S= ø 35 mm, step 152 mm S= ø 35 mm, step 152 mm (ø 1.4”, 6”mm, step 152 mm L= ø 45 steps) L= ø 45 mm, step 152 mm H= ø 35 mm, step 76 mm (ø1.7”, 6” steps) pipe SA0 only “L”) (in case of sinlge H= ø 35 mm, step 76 mm (ø1.4”, 3 steps) (in case of single pipe...

Open the catalog to page 4

All Carel USA catalogs and technical brochures

  1. PCO Sistema

    8 Pages

  2. SUPERNODE

    12 Pages

  3. EASY

    8 Pages

  4. sd:+03U400125

    44 Pages

Archived catalogs

  1. HumiFog

    2 Pages

  2. GasSteam

    2 Pages

  3. HeaterSteam

    2 Pages

  4. CompactSteam

    2 Pages

  5. HumiSteam

    2 Pages