CapaCoustic Melapor Melamine resin foam elements in different sizes, shapes and colours. Product Description Description Material Description CapaCoustic Melapor elements consist of a thermosetting, flexible melamine resin foam with a filigree open-pored structure. System Description CapaCoustic Melapor panels may be bonded either directly as a wall covering or ceiling lining onto the stable substrate or may be positioned to the ceiling as a baffle or floating (suspended) ceiling panel using standard T-shaped guide rails. CapaCoustic Melapor elements are excellently suitable for a later renovation, due to quick mounting and easy handling. System Components I. Direct bonding: ■ CapaCoustic Melapor-Kleber (Adhesive/Glue) Flexible and filled dispersion/emulsion adhesive (glue) for bonding CapaCoustic Melapor-Panels 034/31-43. Product No.: 037/13, Packaging: 25 kg bucket ■ CapaCoustic Melapor-Panel The product range includes various standard formats and surfaces (see table). II. Suspended elements: ■ CapaCoustic Melapor-Baffle The product range includes various standard types (see table). ■ CapaCoustic Melapor Decken-Segel (Floating Ceiling Panel) The product range includes Concave and Convex types (see table). ■ CapaCoustic Abhang-Set (Suspension Set) Optional supplement for individual suspension of CapaCoustic Melapor Baffles. Product No.: 034/20
Open the catalog to page 1Technical Information No. 034 CapaCoustic Melapor Brekki (Degree of acoustic absorbtion αS / Frequency) Type: Smooth Type: Wave α s Third α p Octave α s Third α p Octave
Open the catalog to page 2Technical Information No. 034 CapaCoustic Melapor Panel (Degree of acoustic absorbtion αS / Frequency) Type: Smooth Type: Wave α s Third α p Octave α s Third α p Octave
Open the catalog to page 3CapaCoustic Melapor Baffle, centre distance 935 mm (Degree of acoustic absorbtion cxs / Frequency)
Open the catalog to page 4Technical Information No. 034 CapaCoustic Melapor Baffle, centre distance 625 mm (Degree of acoustic absorbtion αS / Frequency) Type: Rectangle α s Third α p Octave Type: Ellipse α s Third α p Octave α p Octave
Open the catalog to page 5Technical Information No. 034 CapaCoustic Melapor Decken-Segel / Floating Ceiling Panels, approx. 1000 mm suspended from ceiling (Degree of acoustic absorbtion αS / Frequency) Type: Concave Type: Convex Frequency
Open the catalog to page 6Technical Information No. 034 Field of Application For rooms showing an intensive reverberation effect it is very often necessary to take reverberation regulating (suppressing) measures. In such cases the application of systems provided with soundabsorbing properties is used in order to reduce the reverberation time in all relevant rooms. For this purpose special open-porous and head-porous materials are used to reduce the penetrating sound energy. The sound energy reducing effect is achieved by the friction of air molecules (being set into oscillation by sound propagation) with pore sides...
Open the catalog to page 7Technical Information No. 034 II. Suspended elements (hanging down from ceilings): CapaCoustic Melapor Baffle White or colourful coated sound absorbing element in rectangular, round or elliptic shape, showing a smooth surface texture, provided with a prefab T groove. (Rails are not included in the scope of delivery.) Type Units/ Carton III. Suspended elements (hanging down from ceilings): CapaCoustic Melapor Baffle Well-matched fixing elements for individual suspension of CapaCoustic Melapor Baffle. Type ■ 1 unit T-shaped guide rail, length 1190 ■ 2 units fasteners for ceilings ■ 2 units...
Open the catalog to page 8Technical Information No. 034 Application 1. Substrate Preparation The substrate must be even/planar, clean, dry, solid, sound/stable, free from all substances, that may prevent good adhesion and should be slightly absorbent. Carefully remove dust, dirt/soiling and coats of flaking paint. Prime the substrate, if necessary. See Technical Information No. 160 for preparing suitable substrates. 2. Bonding of CapaCoustic Melapor Panels 2.1 Preparation of Adhesive/Glue CapaCoustic Melapor-Kleber (adhesive/glue) is ready for use with notched trowels, without using any further additives. Stir the...
Open the catalog to page 9Technical Information No. 034 4.2 Application of Paint Coat Apply the paint coat only by high pressure or low pressure spraying method. Apply 2-3 mist coats of diluted paint crosswise in a distance of approx. 25 cm. Crosslinking of paint on the surface must be avoided. Airless application is not advisable. 4.3 Consumption Approx. 100 ml/m2 (undiluted) 4.4 Drying of Elements Allow elements/panels to fully dry between working steps/operations. During the drying phase they should be supported on an even substrate or must be hung to keep shape. All elements must be thoroughly dry before they...
Open the catalog to page 10All Caparol catalogs and technical brochures
-
CapaSilan
3 Pages
-
Capadecor Calcino-Decor
4 Pages
-
ThermoSan
4 Pages
-
Dupa-Haftgrund
2 Pages
-
OptiGrund E.L.F.
2 Pages
-
Brochure Floor Compendium
66 Pages
-
Brochure Dalmatiner S-Class
6 Pages
-
Brochure Caparol Edition Carbon
14 Pages
-
Brochure Capaver FantasticFleece
16 Pages
-
Brochure Capadecor Effekt
8 Pages
-
CapaCoustic
36 Pages
-
Brochure Caparol Capacoustic
16 Pages
-
CapaDATA
16 Pages
-
Brochure Paint Guide...
12 Pages