Catalog excerpts
LINEAR WALL CLADDING SYSTEM
Open the catalog to page 1LINEAR WALL CLADDING SYSTEM This system offer wide range of dimension flexibility to architects to cover wall areas. Panel are usually preferred as Aluminum but Galvanized is also offered . It is also possible to have a gap between wall panels by not using closure panels.
Open the catalog to page 2DETAIL VIEW MATERIAL OPTIONS Galvanized Steel/Aluminum ACOUSTIC No acoustic performance offered for this system. HUMIDITY Galvanize panel: 90% RH Aluminum panel: 100 % RH LIGHT REFLECTION Straight Panel: 9010 Painted % 86 Perforated Panel : 9010 Painted % 72 High performance in Blocking bacterial formation on panel surfaces by applying anti-microbial paint. PAINT Prior to paint. Sensitive surface cleaning and phosphate coverage is applied.60 minimum micron powder paint is sprayed by electrostatic system through 6 robots and cooked in a 180 meters long oven. The entire painting process takes...
Open the catalog to page 3ELEMENT SPECIFICATION Closure Panel Galvanized Steel/Aluminum / Stainless Steel Cladding Carrier Galvanized Steel/Aluminum / Stainless Steel ACOUSTIC ACOUSTIC High acoustic performans with acoustic fleece up to αw : 100 HUMIDITY Galvanize panel: 90% RH Aluminum panel: 100 % RH LIGHT REFLECTION Straight Panel: 9010 Painted % 86 Perforated Panel : 9010 Painted % 72 HUMIDITY Galvanize panel: 90% RH Aluminum panel: 100 % RH LIGHT REFLECTION Straight Panel: 9010 Start-End Wall Cladding Panel Galvanized Steel/Aluminum / Stainless Steel ACOUSTIC High acoustic performans with acoustic fleece up to...
Open the catalog to page 4ASSEMBLY TECHNIQUE
Open the catalog to page 7metal form sanayi ve ticaret a.s.
Open the catalog to page 10(a) Column 1 shall contain the list of essential characteristics as determined in the harmonized technical specifications for the intended use or uses indicated in point 3 above, (b) For each essential characteristic listed in column 1 and in compliance with the requirements of Article 6,Column 2 shall contain the declared performance, expressed by level or class, or in a description, related to the corresponding essential characteristics. The letters 'NPD' (No Performance Determined) shall be indicated where no performance is declared, (c) For each essential characteristic listed in column...
Open the catalog to page 11All BUTEM METAL catalogs and technical brochures
-
HOOK-ON SYSTEM
11 Pages
-
T70 System
12 Pages
-
T24 Vector Panel-Lay-in System
12 Pages
-
T24 Seismic System
13 Pages
-
T15 Groove System
12 Pages
-
Slimline System
10 Pages
-
Demontable System
13 Pages
-
T15 Opencell System
12 Pages
-
Multipanel System
13 Pages
-
Move-on System
11 Pages
-
Linear System
12 Pages
-
Linear-100 Multipanel System
12 Pages
-
Lay-on Corridor System
7 Pages
-
T15 Lay-on System
12 Pages
-
T24 Lay-on System
12 Pages
-
T15 Lay-in System
12 Pages
-
T24 Lay-in System
12 Pages
-
Hook-on Corridor System
9 Pages
-
Hook-on Standard System
11 Pages
-
Hidden Baffle Carrier System
10 Pages
-
Geometric System
12 Pages
-
FBS System
16 Pages
-
Expanded Metal Mesh
8 Pages
-
Clip-in Corridor System
11 Pages
-
Clip-in Special System
12 Pages
-
Clip-in Standard System
11 Pages
-
Box System
11 Pages
-
Bandraster System
11 Pages
-
Bafflecell System
11 Pages
-
Island System
8 Pages
-
Baffle System