Catalog excerpts
MISTRAL STREET LIGHTING Open design Modularity Serviceability Diverse optics BUCK GmbH Taunustor 1 60310 Frankfurt am Main office0bucklicht.de www.bucklicht.de tel +49.731.950.32.330 fax +49.731.950.32.332 Copyright © 2017 BUCK, edition: 2 BUCK www.bucklicht.de
Open the catalog to page 1Large number of available light distributions caters for all requirements defined by EN 13201 regarding the quality of traffic illumination, particularly that of M1 - M6, C0- C5, P1- P6, SC1-SC9, EV1-EV6. LED street luminaire of high energy efficiency. Modularity, choice of 28 different lenses and different nominal powers enable continuous adjustment of power from 34W to 441W and flux adjustment from 4910lm to 52400 lm. Lighting management and communication for smart energy consumption. ENERGY EFFICIENCY By choosing appropriate light distribution, depending on pole height and distance...
Open the catalog to page 2The shape of cooling fins was inspired by natural shape of sand dune slopes. OPEN DESIGN Open design concept enables the use of the LED’s to their full potential. The power of luminaire is determined by the number of installed LED modules. Each module consists of a heatsink with vertical ribs of tilted surfaces and sealed LED sources with protective glass. Experience in designing and producing open design luminaires confirmed reliability and durability of such luminaires in extreme outdoor conditions, such as high humidity, high temperatures and big temperature oscillations, as in desert...
Open the catalog to page 3MODYLARITY This approach enables to use only one family of luminaires for illumination the whole range different types of street, regardless the speed limit, traffic volume and composition, junction density, etc. This give us an opportunity to uniform street lamps in whole city area. TOTAL POWER (W) MIN/NOM/MAX.
Open the catalog to page 4OPTICS PMMA lenses of high light transmission (95%) and a tempered, 4mm thick glass protector. Vast range of different powers and lenses cater for wide application in all types of outdoor illumination. The distribution of light is defined by lenses made of optical grade PMMA with high UV and temperature resistance, appropriate for high current and temperature conditions.These lenses allow better targeting of light rays so that the light scattering to adjacent buildings and light pollution is minimized. Numerous light distributions are available due to use of standardized lenses. The...
Open the catalog to page 5CASE STUDY Lighting Class: P2 Eav (lx) Emin (lx) Required values according to class 310.00 32.00 Fulfilled/Not fulfilled ✓ ✓ Application of MISTRAL with fewer number of modules and T2 lenses enables excellent uniformity of illumination of narrow streets or pedestrian lanes. Additional savings are obtained by reduced height of poles and greater spacing between them. Hight: 8m, Overhang: 0m, Boom Angle: 10.0° Lighting Class: M4 Lav (cd/m2) U0 UI TI (%) SR Required values according to class 30.75 30.40 30.60 s15 30.30 Fulfilled/Not fulfilled...
Open the catalog to page 6ME OPTICS - BUCK 7018 MISTRAL 4 ME CASE STUDY Application of MISTRAL with ME optics and large number of modules provides illumination for regional roads, highways and access roads, containing several lanes in both directions. Meets the requirements regarding high levels of luminance and uniformity (as for classes M1 and M2). Hight: 12 m, Overhang: 1.5 m, Boom Angle: 0° Lighting Class: P1 Eav (lx) Emin (lx) Required values according to class 315.00 33.00 Fulfilled / Not fulfilled ✓ ✓ Lighting Class: M2 Lav (cd/m2) U0 UI TI (%) SR Required values according...
Open the catalog to page 7The table compares the solution with existing luminaire using HPS 250 W and the solution with MISTRAL 4 with standard tuning without optimization and smart function and with standard tuning including all additional functions such as AOC, autonomous dimming, CLO. Installed Yearly energy Yearly energy Maintenance Power Energy ROI power consumption consumption cost savings savings period Mistral 4 - with optimisation The table compares the solution with existing luminaire using HPS 250 W and the solution with MISTRAL 4 with standard tuning, including all...
Open the catalog to page 8Dimensions A/B/H Ingress protection rating Impact resistance rating Finish Weight Ta LENS LOR Luminaire luminous flux (ta=25°) Total power LED EF. Luminaire EF. Luminaire LOR Light colour temperature /CRI LED service life Power supply Const.current range Control gear The housing of the luminaire is made of die cast aluminium, protected by epoxy powder coating resistant to UV radiation. Conversion coating provides better top coating adhesion and superior corrosion resistance. Housing is modular, with exchangeable modules consisting of LED PCB integrated into a self-cleaning aluminum heatsink...
Open the catalog to page 9ADDITIONAL EQUIPMENT • Wireless interface communication • Programmable • AOC - Adjustable Output Current • CLO - Constant light output • Virtual midnight • Protection against transient main peaks up 6 kV • Electronic short-circuit protection • Overload protection • Termal protection • Voltage range 198-264VAC • Safety swich • 1-10V analogue management • Power line communication • Central management • DALI communication • Protection against transient main peaks up 10 kV • Voltage range 150-264VAC • Photocell and master sensor communication • RF antenna Angle adjustment Photocell /
Open the catalog to page 10Tool- free access to electrical components. Inspection door serves as control gear holder, for quick replacement or upgrade to new generation. LED modules are serviced using standard tools. Possibility to perform maintenance by merely replacing the door with another spare one, using quick connectors, without interruption in illumination level or operating of the whole lighting installation. Mounting directly on arm Ø60 mm (side entry 42- 60 mm) with possibility to adjust the angle ±10° in 5° increments. SIMPLE UPGRADE EASY ACCESS Mounting on pole Ø76 mm (top entry Ø60– Ø76 mm with adapter).
Open the catalog to page 11All Buck d.o.o. catalogs and technical brochures
-
ARIA SMART
14 Pages
-
VIHOR
14 Pages
-
Tangram HB brochure
18 Pages
-
Neo linea brochure
6 Pages
-
Medico brochure
12 Pages
-
Clean room brochure
12 Pages
-
Aria brochure
14 Pages
-
Company profile
5 Pages
-
System S
38 Pages
-
New lighting solution
16 Pages
-
LIGHT UP
254 Pages
-
NEO LINEA IND
6 Pages
-
CLEAN ROOM
12 Pages
-
MEDICO
12 Pages
-
BUCK
15 Pages
-
Light+Health
150 Pages