PIR+US flush-mounted SCS Green Switch 574048 067226 HD/HC/HS4658 574098 AM5658 L/N/NT4658N Description Front view This devices features a PIR and US (ultrasound) movement detector, and a brightness sensor for automatic activation of various types of loads following the detection of a movement, and a brightness level lower than the set level. The enabling/disabling of the load can also be performed manually using the appropriate front pushbutton and/or using an external BUS control device. It is possible to configure several operating modes; for the detailed descriptions see page 4. Standards, Certifications, Marks Directive: – Electromagnetic Compatibility Directive 2004/108/EC Installation regulations: – CEI 64-8 Product regulations: – IEC 60669-2-1 – EN 50428 Environmental regulations: – EU Directive 2002/96/EC: WEEE (Waste Electrical and Electronic Equipment) – EU Directive 2002/95/EC: RoHS (Restriction of Hazardous Substances) 4 Legend 1. PIR sensor 2. LEARN LED Dimensional data 2 flush mounted modules A 4. ON-OFF button 5. LEARN button 6. Movement detector sensor (under the lens) 7. Infrared transmitter (under the lens) 8. Brightness sensor Technical data Voltage: Current draw: Connection between sensor and actuator: Sensor type: Flush mounted box depth: Weight: Impact resistance: Penetration of solids and liquids: Time delay: Brightness: Operating temperature: Storage temperature: 27 V= 17 mA SCS BUS connector movement detector (PIR+US) with 180° detection angle and brightness sensor. 40 mm 60 g IK04 IP20 from 5 sec to 59 min. 59 sec from 20 lux to 1275 lux from - 5 °C to + 45 °C from - 20 °C to + 70 °C

Open the catalog to page 1
PIR+US flush-mounted SCS Green Switch - 2

PIR+US flush-mounted SCS Green Switch 574048 067226 HD/HC/HS4658 574098 AM5658 L/N/NT4658N Installation Positioning the sensor PIR Position the sensor so that it is not affected by the artificial light already present in the room. 1m 2,5 m ≥ 2,5 m Settings Default value Time delay PIR (very high) / US (high) Brightness threshold Detection mode Operating mode Sensor parameters Time delay The period of time after which the load is switched off if no movement is detected. The time restarts whenever the sensor detects a movement. Sensitivity Adjustment of the sensitivity of the detection...

Open the catalog to page 2
PIR+US flush-mounted SCS Green Switch - 3

PIR+US flush-mounted SCS Green Switch 574048 067226 HD/HC/HS4658 574098 AM5658 L/N/NT4658N If a movement is detected for a time of less than 20 s, the sensor will decrease the set time delay to 3 minutes. If the set delay time set is already less than three minutes, it will remain as such. Eco The load is switched on manually while switching off is automatic: - if no movement is detected at the end of the set delay time. After switching off the load, if any movement is detected within 30 s, the load is automatically switched back on (retrigger function on). At the end of this time interval,...

Open the catalog to page 3
PIR+US flush-mounted SCS Green Switch - 4

PIR+US flush-mounted SCS Green Switch 574048 067226 HD/HC/HS4658 574098 AM5658 L/N/NT4658N Configuration 1. Lighting Management System When installed in a Lighting Management system, the device can be configured in the following ways: - Plug & Go: automatic procedure for pairing devices connected to the inputs and outputs. The procedure is activated on powering the device. It is only available for Room Controllers or, in the case of other devices, paired with the Room Controllers. - Push & Learn: procedure for pairing different connected devices or changing the assignments defined...

Open the catalog to page 4
PIR+US flush-mounted SCS Green Switch - 5

PIR+US flush-mounted SCS Green Switch 574048 067226 HD/HC/HS4658 574098 AM5658 L/N/NT4658N 1) Duration of the lights timer depending on the configurator on T: Configurator on T No configurator 1 2 2) Sensitivity of the PIR movement detector depending on the configurator on S: Configurator on S No configurator 1 2 Sensitivity Low Medium High Very high 3) Sensitivity of the lights sensor depending on the configurator on D: Configurator on D No configurator 1 2 Wiring diagram Maintenance Keep the lenses clean. Clean the surface with a cloth. Do not use: acetone, detergents for removing tar, or...

Open the catalog to page 5

All Bticino catalogs and technical brochures

  1. D45 System

    7 Pages

  2. LINEA 100

    2 Pages

  3. LINEA 300

    2 Pages

  4. SOLIDA

    12 Pages

  5. XCP

    108 Pages

  6. LIVING NOW

    134 Pages

  7. Classe 100

    32 Pages

  8. 364232

    2 Pages

  9. BUSBAR SYSTEM

    166 Pages

  10. HOMETOUCH

    8 Pages

  11. CLASSE 300

    32 Pages

  12. AXIAL SWITCH

    4 Pages

  13. MÀTIX

    40 Pages

  14. AIR

    28 Pages

  15. D45 catalogue

    14 Pages

  16. Transcoding

    4 Pages