1. Catalogs
  2. Bticino
  3. GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS

GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS

GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS
1 / 16 PagesView full catalog

GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS

Product catalog summary
General Features
The document describes the Green T.HE high-efficiency cast resin transformers, which adhere to the EN 50588-1 Standard and European Commission Regulation 548/2014 for ecodesign. These transformers are engineered to lower energy consumption and CO2 emissions, providing both economic and environmental advantages.

Technical Information
Green T.HE transformers are categorized by no-load losses (P0) and load losses (Pk). The document highlights the significance of reducing partial discharges to improve transformer durability and performance. These transformers are ACAE certified and come with an 8-year warranty.

Advantages
The transformers are designed to keep partial discharges below 5 picocoulombs, reflecting the use of high-quality materials and manufacturing processes. This results in enhanced resistance to operational stresses and a prolonged lifespan.

Standards and Tests
The transformers undergo various acceptance tests according to IEC 60076-11, including winding resistance, voltage ratio, and partial discharge measurements. Type and special tests are available upon request.

Catalogue and Specifications
The catalogue provides detailed specifications for transformers with insulation classes of 12 kV, 17.5 kV, 24 kV, and 36 kV, including primary and secondary voltages, power ratings, and dimensions.

Environmental Impact
The Product Environmental Profile (PEP) document details the environmental impact of the transformers throughout their lifecycle, focusing on recyclability and disposal.
Specifications
The document offers detailed specifications for Green T.HE cast resin transformers, including insulation classes of 24 kV and 36 kV. It lists various models with their power ratings (kVA), primary and secondary voltages, losses (Po and Pk), dimensions, and weights. Transformers are categorized by series and item codes, with specific acoustic power levels and wheel dimensions.

Ventilation and Power Increase
Ventilation busbars can temporarily boost the rated power of transformers under normal service conditions, with specific codes for different power ranges. The document references IEC 60076-1 standards for transformer classification.

Temperature Measurement and Control
Temperature measurement probes (Pt100 and PTC) are available for installation on low voltage windings and cores. Various temperature control devices are listed, including fan control and temperature control units for Pt100 and PTC probes.

Surge Arrester Kits
Surge arrester kits are available for different nominal voltages (Vn), with specific catalog numbers provided.

Installation Accessories
The document details installation accessories such as rubber supports for anti-vibration, Cupal plates for bimetallic connections, and boxes for housing transformers. Box dimensions, IP degrees, and weight are specified for different power ranges.

Additional Information
The document includes notes on the availability of pre-assembled boxes and the option to add a suffix for pre-assembly. It also mentions the right to modify the content and provides contact information for the head office and international department.
See more

Catalog excerpts

GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-1

GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

 Open the catalog to page 1
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-3

Index 4-6 General features Green T.HE cast resin transformers Advantages of Green T.HE transformers Certified quality Resin Green T.HE 12 kV insulation class 17,5 kV insulation class 24 kV insulation class 36 kV insulation class Installation accessories

 Open the catalog to page 3
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-4

resin Transformers With the application in July 2015 of the European Commission Regulation for ecodesign, efficiency standards of transformers will be more strenght The Green T.HE Transformers comply with the EN 50588-1 Standard. They are designed and manufactured according to the Regulation 548/2014 of European Commission and the new Ecodesign guidelines 2009/125/CE. Legrand Green T.HE Transformers, designed and manufactured in accordance with new Regulation, ensure a consistent reduction in energy consumption, resulting in economic savings and the decrease of CO2 emissions released into the...

 Open the catalog to page 4
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-5

CLASSIFICATION The classification of a cast resin transformer depends on the value of the no-load losses (P0), as well as the load losses (Pk). More precisely P0 losses are independent from the load and remain constant for the whole period the transformer is connected to the electric power network. On the other hand, Pk losses only occur when the transformer is connected to a load and they are proportional to the square of the load. ECODESIGN REQUIREMENTS

 Open the catalog to page 5
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-6

TRANSFORMERS Low, partial discharges, HIGH Quality According to the product standard related to design of resin transformers (CEI EN 60076-11, i.e. IEC 60076-11), all the windings with a voltage ≥ 3.6kV should be subjected to the measurement of the partial discharges and the value measured should not exceed 10 picocoulombs (pC). Partial discharges are a microscopic phenomena occurring inside insulating resin cavities and can speed up ageing. For this reason, it is important that the values of such currents are limited. A low value of partial discharges gives an indication of the positive factors,...

 Open the catalog to page 6
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-7

Reliability guaranteed With Green T.HE series, Legrand provides customers a top-quality product which guarantees long-term excellent performance and reliability. When the Green T.HE transformers are subjected to partial discharges (according to CEI 60076-1 1, i.e. IEC 60076-1 1), values under 5 pC have been always been achieved (which exceeds the requirement of the standard which establishes the maximum value at 10 pC). Thanks to the excellent quality of products, Legrand has extended its GUARANTEE to 8 YEARS for all its transformers with standard features (*). Green T.HE series is certified...

 Open the catalog to page 7
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-8

A A Q A £ TESTING AUTHORIZATION A CAE tare per fn ('ertifiearwne dcfie Appareechiitiurv Ek'trhehef Member of LOVAG (fjnv I1WhiRir Agreement Group) authorises the Laboratory B Ticino S.p.A. based in Via E. Ferrari JJ, ViUa Zaccheo - 64020 Casfellalta (TE) I.abomMty t'&iitficittinn number, fB 03 to ettrr? *mi fht tern toted m the fititowittg, for the propane io certify the prm/tto’t* iV Jtahif m the < 'cmfk'aie ft° OTQR and tet enctmurv, tsav&t to Ai Afi by A( 'CREDtA. J.nt of the authorized flpflS an the power transformer*; Wi.YiuwrrnivJJ nf Mjdr.rjLfr Hiltirjttmi, tn i ,*f ptttiu- iftifiLntmeirt...

 Open the catalog to page 8
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-9

Resin Green T.HE Compliance with standard: IEC 60076-11 and EN 50588-1 Power (kVA): 100–3150 Frequency (Hz): 50 Adjustment, MT side: ± 2 x 2.5% Thermal class of the insulating system: 155 °C (F) / 155 °C (F) Temperature rise: 100/100 K Class of use: E2-C2-F1 Certified CESI A9032391 IEC 60076-11 Tolerances on losses: 0% Other tolerances: According to IEC/CEI Primary voltages (kV): 6-10-11. Insulation class: 12 kV BIL 60 kV (BIL 75 kV available on request at no extra charge, to be specified at the time of order) Secondary voltages no-load (V): 400-433 (insulation class 1.1 kV) Primary voltages...

 Open the catalog to page 9
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-10

SR Series Item Uk Primary Secondary Po Pk lo LwA-Acoustic Length Width Height Ic - wheel R - wheel Weight BOX [kVA] (Reg548) [%] voltage voltage [W] [W] a [%] power (A) (B) (C) centre line diameter [kg] type*

 Open the catalog to page 10
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-14

Ventilation bars The ventilation busbars temporarily increase the rated power (under normal service conditions). According to standard IEC 60076-1, a transformer is called AN even if it is equipped with discontinuous ventilation. If a transformer with AF continuous service is requested, it is not possible to refer to the codes included in this catalogue, but the transformer will be designed according to the customer's needs. Rubber supports (anti vibration) A temporary increase in rated conditions Cupal plates Description 4 buffers supplied for mounting under the transformer casters 4 buffers...

 Open the catalog to page 14
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS-16

FOLLOW US ALSO ON @ www.legrand.com El www.youtube.com/legrand ^ twitter.eom/@legrand

 Open the catalog to page 16
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.