Catalog excerpts
GREEN T.HE HIGH EFFICIENCY CAST RESIN TRANSFORMERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
Open the catalog to page 1Index 4-6 General features Green T.HE cast resin transformers Advantages of Green T.HE transformers Certified quality Resin Green T.HE 12 kV insulation class 17,5 kV insulation class 24 kV insulation class 36 kV insulation class Installation accessories
Open the catalog to page 3resin Transformers With the application in July 2015 of the European Commission Regulation for ecodesign, efficiency standards of transformers will be more strenght The Green T.HE Transformers comply with the EN 50588-1 Standard. They are designed and manufactured according to the Regulation 548/2014 of European Commission and the new Ecodesign guidelines 2009/125/CE. Legrand Green T.HE Transformers, designed and manufactured in accordance with new Regulation, ensure a consistent reduction in energy consumption, resulting in economic savings and the decrease of CO2 emissions released into...
Open the catalog to page 4CLASSIFICATION The classification of a cast resin transformer depends on the value of the no-load losses (P0), as well as the load losses (Pk). More precisely P0 losses are independent from the load and remain constant for the whole period the transformer is connected to the electric power network. On the other hand, Pk losses only occur when the transformer is connected to a load and they are proportional to the square of the load. ECODESIGN REQUIREMENTS
Open the catalog to page 5TRANSFORMERS Low, partial discharges, HIGH Quality According to the product standard related to design of resin transformers (CEI EN 60076-11, i.e. IEC 60076-11), all the windings with a voltage ≥ 3.6kV should be subjected to the measurement of the partial discharges and the value measured should not exceed 10 picocoulombs (pC). Partial discharges are a microscopic phenomena occurring inside insulating resin cavities and can speed up ageing. For this reason, it is important that the values of such currents are limited. A low value of partial discharges gives an indication of the positive...
Open the catalog to page 6Reliability guaranteed With Green T.HE series, Legrand provides customers a top-quality product which guarantees long-term excellent performance and reliability. When the Green T.HE transformers are subjected to partial discharges (according to CEI 60076-1 1, i.e. IEC 60076-1 1), values under 5 pC have been always been achieved (which exceeds the requirement of the standard which establishes the maximum value at 10 pC). Thanks to the excellent quality of products, Legrand has extended its GUARANTEE to 8 YEARS for all its transformers with standard features (*). Green T.HE series is...
Open the catalog to page 7A A Q A £ TESTING AUTHORIZATION A CAE tare per fn ('ertifiearwne dcfie Appareechiitiurv Ek'trhehef Member of LOVAG (fjnv I1WhiRir Agreement Group) authorises the Laboratory B Ticino S.p.A. based in Via E. Ferrari JJ, ViUa Zaccheo - 64020 Casfellalta (TE) I.abomMty t'&iitficittinn number, fB 03 to ettrr? *mi fht tern toted m the fititowittg, for the propane io certify the prm/tto’t* iV Jtahif m the < 'cmfk'aie ft° OTQR and tet enctmurv, tsav&t to Ai Afi by A( 'CREDtA. J.nt of the authorized flpflS an the power transformer*; Wi.YiuwrrnivJJ nf Mjdr.rjLfr Hiltirjttmi, tn i ,*f ptttiu-...
Open the catalog to page 8Resin Green T.HE Compliance with standard: IEC 60076-11 and EN 50588-1 Power (kVA): 100–3150 Frequency (Hz): 50 Adjustment, MT side: ± 2 x 2.5% Thermal class of the insulating system: 155 °C (F) / 155 °C (F) Temperature rise: 100/100 K Class of use: E2-C2-F1 Certified CESI A9032391 IEC 60076-11 Tolerances on losses: 0% Other tolerances: According to IEC/CEI Primary voltages (kV): 6-10-11. Insulation class: 12 kV BIL 60 kV (BIL 75 kV available on request at no extra charge, to be specified at the time of order) Secondary voltages no-load (V): 400-433 (insulation class 1.1 kV) Primary...
Open the catalog to page 9SR Series Item Uk Primary Secondary Po Pk lo LwA-Acoustic Length Width Height Ic - wheel R - wheel Weight BOX [kVA] (Reg548) [%] voltage voltage [W] [W] a [%] power (A) (B) (C) centre line diameter [kg] type*
Open the catalog to page 10Ventilation bars The ventilation busbars temporarily increase the rated power (under normal service conditions). According to standard IEC 60076-1, a transformer is called AN even if it is equipped with discontinuous ventilation. If a transformer with AF continuous service is requested, it is not possible to refer to the codes included in this catalogue, but the transformer will be designed according to the customer's needs. Rubber supports (anti vibration) A temporary increase in rated conditions Cupal plates Description 4 buffers supplied for mounting under the transformer casters 4...
Open the catalog to page 14FOLLOW US ALSO ON @ www.legrand.com El www.youtube.com/legrand ^ twitter.eom/@legrand
Open the catalog to page 16All Bticino catalogs and technical brochures
-
Energy Data Logger
1 Pages
-
D45 System
7 Pages
-
LINEA 100
2 Pages
-
LINEA 300
2 Pages
-
SOLIDA
12 Pages
-
XCP
108 Pages
-
LIVING NOW
134 Pages
-
Classe 100
32 Pages
-
364232
2 Pages
-
BUSBAR SYSTEM
166 Pages
-
HOMETOUCH
8 Pages
-
Hotel Room Management
16 Pages
-
MEGASWITCH Disconnectors
6 Pages
-
CLASSE 300
32 Pages
-
AXIAL SWITCH
4 Pages
-
New TV SOCKETS
8 Pages
-
MÀTIX
40 Pages
-
AIR
28 Pages
-
CES_2015_ZIGBEE_gb
2 Pages
-
D45_brochure_GB
28 Pages
-
GENERAL CATALOGUE
202 Pages
-
video door entry sYstem offer
72 Pages
-
Livinglight - Catalogue 2014
156 Pages
-
My HOME FLATWALL
44 Pages
-
Màtix - Catalogue 2014
82 Pages
-
Axolute - Catalogue 2014
156 Pages
-
My home complete guide
1152 Pages
-
Telephone system technical guide
72 Pages
-
Easy and flexible solutions
32 Pages
-
D 45 technical guide
156 Pages
-
D45 catalogue
14 Pages
-
New audio solution
8 Pages
-
Transcoding
4 Pages
-
Sfera catalogue
16 Pages
-
Classe 100 Catalogue
4 Pages