Catalog excerpts
GENERAL CATALOGUE A Group brand Q legiand
Open the catalog to page 1Devices for Low Voltage energy distribution Thermal magnetic Mcb’s from 4.5 to 25kA BTDIN circuit breakers and devices for DIN35 rail Other protective devices MEGATIKER moulded case circuit breakers MEGASWITCH disconnectors MEGABREAK air circuit breakers Supervision and metering systems Switchboards, MAS distribution boards and cabinets TIPLUG, industrial sockets and plugs Control and protection devices Supervision devices Plastic switchboards Interlocked sockets Thermal magnetic Mcb’s and earth leakage modules up to 125A
Open the catalog to page 2Earth leakage thermal magnetic Mcb’s String boxes Electronic control units Moulded case circuit breakers up to 250A for DIN35 rail Control devices and relays Earth leakage modules Signalling devices Earth leakage circuit breakers Electrical auxiliaries Time control devices Industrial sockets and plugs P. 111 METERING AND SUPERVISION New multifunction metering instruments and power meters P. 49 SOLUTIONS FOR PHOTOVOLTAIC SPDs (Surge Protective Devices) and control devices for photovoltaic systems
Open the catalog to page 3■ Thermal magnetic Mcb's with rated current ■ Wide range of earth leakage devices ■ Electrical auxiliaries for control and signalling MORE FUNCTIONS ■ SPDs (Surge Protective Devices] ■ Signalling devices and time control
Open the catalog to page 4Icn= 4500A - thermal magnetic Mcb’s and earth leakage thermal magnetic Mcb’s Rated breaking capacity 4500A CEI EN 60898-1 Rated breaking capacity 4500A CEI EN 61009-1 for earth leakage thermal magnetic Mcb’s NOTE: The circuit breakers are not fitted with plug-in terminals and do not allow the coupling with earth leakage modules. The circuit breakers item F810N... and item F820... cannot be accessorised with contacts and releases. EARTH LEAKAGE THERMAL MAGNETIC MCB’S (C CURVE) One-pole + neutral - 230 Vac In (A) I∆n (A) No. of modules 6 10 13 16 20 25 32 40 SALVAVITA STOP&GO KIT FOR BTDIN45...
Open the catalog to page 5Icn= 4500A - thermal magnetic Mcb’s Rated breaking capacity 4500A CEI EN 60898-1
Open the catalog to page 6Icn= 4500A - earth leakage thermal magnetic Mcb’s AC type Earth leakage circuit breakers capable of ensuring protection in case of instantly applied or slightly increasing alternate fault currents. Thanks to their protection features, these circuit breakers are widely used in domestic applications and similar. A type Earth leakage circuit breakers ensuring the same type of protection as the AC types, but with the addition of also being able to guarantee protection in case of alternate fault currents with unidirectional impulse components. These devices are widely used in the...
Open the catalog to page 7lcn= 6000A - thermal magnetic Mcb's Rated breaking capacity 6000A THERMAL MAGNETIC MCB'S THERMAL MAGNETIC MCB'S
Open the catalog to page 8Icn= 6000A - earth leakage thermal magnetic Mcb’s Rated breaking capacity 6000A - CEI EN 61009-1 EARTH LEAKAGE THERMAL MAGNETIC MCB’S (C CURVE) One-pole + neutral - 230 Vac In (A) I∆n (A) No. of mod. 2 3 1/2 N 4 T 6 10 0.03 2 16 2/1 N 20 25 32 40 One-pole + neutral - 230 Vac In (A) I∆n (A) No. of mod. 6 1/2 N 10 16 20 0.3 2 25 2/1 N 32 40 EARTH LEAKAGE THERMAL MAGNETIC MCB’S (C CURVE) Four-pole - 400 Vac In (A) I∆n (A) No. of mod. 6 10 16 0.03 4 20 25 32 1/2 3/4 5/6 7/8
Open the catalog to page 9Icn= 10000A - thermal magnetic Mcb’s Rated breaking capacity 10000A - CEI EN 60898-1 Item C curve NOTE: For the availability of K and Z curve devices, refer to your technical sales representative. Z curve = 2.4-3.6 In K curve = 10-14 In
Open the catalog to page 10Icu= 16kA - Thermal magnetic Mcb’s THERMAL MAGNETIC MCB’S One-pole - 230/400 Vac In (A) No. of mod. 80 1.5 100 1.5 125 1.5
Open the catalog to page 11Icu= 25kA - thermal magnetic Mcb’s Ultimate breaking capacity 25000A CEI EN 60947-2 THERMAL MAGNETIC MCB’S One-pole - 230/400 Vac In (A) No. of mod. 80 1.5 100 1.5 125 1.5
Open the catalog to page 12lcu= 50kA - thermal magnetic Mcb's Ultimate breaking capacity 50000A lcu= 25kA - only magnetic Ultimate breaking capacity 25000A Magnetic tripping curve 12-14 In THERMAL MAGNETIC MCB'S
Open the catalog to page 13EARTH LEAKAGE MODULES for BTDIN45/60/100/160/250 CEI EN 61009-1 The earth leakage modules can be associated with the BTDIN45/60/100/160 circuit breakers with rated current up to 63A and to the BTDIN250 circuit breakers up to 25A. NOTE: The A type AH (HPI) earth leakage devices performs high disturbance resistance. The AH (HPI) earth leakage devices are capable of supporting 8/20µs current pulses of up to 3 kA, the A-S devices are capable of supporting up to 5kA (8/20µs)
Open the catalog to page 14EARTH LEAKAGE MODULES for BTDIN160/250/500 (1.5 modules for each pole) CEI EN 61009-1 Earth leakage modules for BTDIN250 with rated current from 32 to 63A (1.5 modules for each pole) and for BTDIN500. Earth leakage modules for BTDIN160/250 with rated current from 80 to 125A. NOTE: The A type AH (HPI) earth leakage devices performs high disturbance resistance. The AH (HPI) earth leakage devices are capable of supporting 8/20µs current pulses of up to 3 kA, the A-S devices are capable of supporting up to 5kA (8/20µs)
Open the catalog to page 15EARTH LEAKAGE CIRCUIT BREAKERS Earth leakage without built-in overcurrent releases CEI EN 61008-1 IN/OUT connections from above Possibility of wiring with combs G72... 2 POLES - 230 Vac I∆n= 0.03A In (A) I∆n (A) No.of mod. 25 0.03 2 40 0.03 2 WIRING COMBS No. of modules 5 7 11 57 A type EARTH LEAKAGE TYPE B - 2 POLES - 400 Vac EARTH LEAKAGE TYPE B - FOUR-POLE - 400 Vac A type B type NOTE: The A type AH (HPI) earth leakage devices performs high disturbance resistance. The AH (HPI) earth leakage devices are capable of supporting 8/20µs current pulses of up to 3 kA, the A-S devices are capable...
Open the catalog to page 16CONTACTS AND RELEASES FEATURES OF AUXILIARY AND ALARM CONTACTS Standards Rated voltage Vn Utilization category Max. section of flexible cable (mm2) FEATURES OF SHUNT TRIPS (ITEM F80ST...) Standards AUXILIARY AND ALARM CONTACTS Contact Type No. of modules 1NO/NC AUX 1 1NO/NC ALL 1 2NO/NC AUX+AL 1 1NO/NC AUX+AL 0.5 Rated voltage Vn Operating voltage (% Vn): Tripping time (ms): Max. absorbed power at activation (W): Total resistance (ohm) SHUNT TRIPS Vn (V) 12-48 ac/dc 110-415 ac 110-125 dc Current absorbed at min/max voltage (mA) Max. section of flexible cable (mm2): FEATURES OF UNDERVOLTAGE...
Open the catalog to page 17All Bticino catalogs and technical brochures
-
Energy Data Logger
1 Pages
-
D45 System
7 Pages
-
LINEA 100
2 Pages
-
LINEA 300
2 Pages
-
SOLIDA
12 Pages
-
XCP
108 Pages
-
LIVING NOW
134 Pages
-
Classe 100
32 Pages
-
364232
2 Pages
-
BUSBAR SYSTEM
166 Pages
-
HOMETOUCH
8 Pages
-
Hotel Room Management
16 Pages
-
MEGASWITCH Disconnectors
6 Pages
-
CLASSE 300
32 Pages
-
AXIAL SWITCH
4 Pages
-
New TV SOCKETS
8 Pages
-
MÀTIX
40 Pages
-
AIR
28 Pages
-
CES_2015_ZIGBEE_gb
2 Pages
-
D45_brochure_GB
28 Pages
-
video door entry sYstem offer
72 Pages
-
Livinglight - Catalogue 2014
156 Pages
-
My HOME FLATWALL
44 Pages
-
Màtix - Catalogue 2014
82 Pages
-
Axolute - Catalogue 2014
156 Pages
-
My home complete guide
1152 Pages
-
Telephone system technical guide
72 Pages
-
Easy and flexible solutions
32 Pages
-
D 45 technical guide
156 Pages
-
D45 catalogue
14 Pages
-
New audio solution
8 Pages
-
Transcoding
4 Pages
-
Sfera catalogue
16 Pages
-
Classe 100 Catalogue
4 Pages