video corpo

D45 System
7Pages

{{requestButtons}}

Catalog excerpts

D45 System - 1

3.5 “ Colour handsfree internal unit Front view D45 System colour handsfree internal unit with 3.5” LCD backlit display. Complete door entry functions with alarms management. International standard SOS pushbutton and keyboard for intercom function and programming device. Direct call to switchboard function. 12 ring tones selectable for different call types. Surge protection. Wall mount installation. Technical data Power supply: Stand by absorption: Max. operating absorption: Operating temperature: LCD display resolution: Dimensional data 1. Loudspeaker 2. 1 to 8 defence status area LEDs 3. 3.5” LCD backlit display 4. Microphone 5. Door lock activation key 6. Monitoring key 7. Call to the switchboard key 8. Audio connection activation/deactivation key 9. SOS pushbutton 10. Information status LED 11. Connection status LED 12. Shortcut key 13. Numerical keyboard 14. Ring volume control knob 15. Display brightness regulation knob 16. Display colour regulation knob

Open the catalog to page 1
D45 System - 2

3.5 “ Colour handsfree internal unit Rear view Device MUST be configured for following parameters: FF : Floor number II : Apartment number #II : Maximum apartments quantity per floor in a riser Two different configuration modes available for whole system: configuration MODE 1 and configuration MODE 2. The main characteristics for each configuration mode are listed below. When the biggest number of #FF in whole system is ≤ 20, and the biggest number of #II is ≤4, and the total risers number is ≤ 50, we recommend to choose (MODE 1) configuration for system. When the biggest number of #FF in...

Open the catalog to page 2
D45 System - 3

3.5 “ Colour handsfree internal unit Two different device configuration ways available: Configuration settings by device keyboard - WAY 1 Configuration settings by inserting phisical configurators - WAY 2 Configuration settings by device keyboard - WAY 1: When the handset is in standby and all zone alarms are disabled, press “#”, then enter the fixed installer password 686868, and press “#” to confirm. If the wrong password is entered, 3 short beeps will be heard; if the password is correct, an extended beep will be heard, and the unit will switch to installation setup status. The 8 alarm...

Open the catalog to page 3
D45 System - 4

3.5 “ Colour handsfree internal unit FROM PREVIOUS PAGE → Configuration settings by device keyboard - WAY 1: installation settingS operation list TABLE SETUP operation code and light status next operation 23# Message light is off. 8 alarm lights will indicate status of infrared sensor. Setting: infrared sensor: light of this alarm zone will be on. Non-infrared sensor, light of this alarm defence area zone will be off. meaning and information for the operation infrared sensor for alarm zone 5: LED 5 on, 1 long tone non- infrared sensor for alarm zone 5: LED 5 on, 1 long tone return to...

Open the catalog to page 4
D45 System - 5

3.5 “ Colour handsfree internal unit Configuration settings by device keyboard - WAY 2: MASTER and SLAVE settings Slave FF: Floor number II: Apartment number #II: Maximum apartments quantity per floor in a riser Configuration examples: Example (A): The number of handsets is 1204, each floor has 4 handsets, the system configuration mode is MODE 1, the handset configuration should be as follows: Set the master and slave handsets Position configuration value Or not jump Set as the slave handset Because the default value of #II is 4, no configurator is needed Example (B): The number of handsets...

Open the catalog to page 5
D45 System - 6

sensor 8 sensor 8 sensor 7 sensor 7 sensor 8 8 sensor 6 sensor 7 sensor 6 7 5 sensor 5 sensor 6 sensor 6 sensor 8 gas sensor 5 gas sensor sensor 5 sensor sensor 7 smoke sensor smoke gas sensor gas sensor sensor sensor 6 door sensor sensor door sensor smoke smoke sensor sensor 5 door sensor door sensor gas sensor infrared sensor infrared sensor smoke sensor door sensor infrared sensor NO infrared sensor NO NC C NO GND NC 12 C V NOTE: 10 KΩ resistors are used to detect cable by cut or cable short circuited to GND. Resistors must be placed near the sensor. IU can afford 12 Vdc - 300 mA sensor...

Open the catalog to page 6
D45 System - 7

3.5 “ Colour handsfree internal unit NC & NO alarm sensors connection table ALARM AREA SENSOR TYPE INFRARED SENSOR Theft alarm Can use short key to sensor active or idle DOOR SENSOR SMOKE SENSOR FIRE alarm SENSOR TYPE Can’t use short key to let sensor idle GAS SENSOR Infrared or non-infrared; Default is infrared sensor; User can set it to be non infrared Infrared or non-infrared; Default is non-infrared sensor; User can set it to be non infrared Infrared or non-infrared; Default is infrared sensor; User can set it to be non infrared Infrared or non-infrared; Default is non-infrared sensor;...

Open the catalog to page 7

All Bticino catalogs and technical brochures

  1. LINEA 100

    2 Pages

  2. LINEA 300

    2 Pages

  3. SOLIDA

    12 Pages

  4. XCP

    108 Pages

  5. LIVING NOW

    134 Pages

  6. LIVING NOW

    134 Pages

  7. Classe 100

    32 Pages

  8. 364232

    2 Pages

  9. BUSBAR SYSTEM

    166 Pages

  10. HOMETOUCH

    8 Pages

  11. CLASSE 300

    32 Pages

  12. AXIAL SWITCH

    4 Pages

  13. MÀTIX

    40 Pages

  14. AIR

    28 Pages

  15. D45 catalogue

    14 Pages

  16. Transcoding

    4 Pages