1. Catalogs
  2. Bruag Design Factory AG
  3. A.7 Technical Sheet Garden Design

A.7 Technical Sheet Garden Design

A.7 Technical Sheet Garden Design
1 / 19 PagesView full catalog

A.7 Technical Sheet Garden Design

Product catalog summary
General Information
The CELLON® panels are high-pressure laminate panels ideal for outdoor applications, consisting of 70% cellulose and 30% phenolic resin. They are weather and frost-resistant, suitable for facades and balcony railings. Available in various raw widths and lengths, they can be customized using laser technology for specific project needs. Panels should be stored vertically and cleaned with water or a magic sponge.

Fastenings
Fastening guidelines are provided for both perforated and plain panels, with specific distances based on wind load and panel thickness. Fasteners include truss-head screws and blind rivets, with specific materials and dimensions outlined. Proper placement in drilled holes is crucial, and countersunk screws should not be used.

Substructure
Panels can be fixed on primary post constructions or secondary profiles, with guidelines for post spacing and material standards. Compliance with static and structural guidelines is the installer's responsibility.

Construction Solutions
Various methods for panel installation are detailed, including screwing with or without perforation, clamping between post systems, and fixing to stone walls with L or U profiles. Each method includes visualization and floor plan guidance.

Plant Boxes
Plant boxes made of CELLON® can serve as non-fixed privacy screens, with customizable back panels. Maximum dimensions for plant boxes and light boxes are provided.

Design
The document references a catalogue for the complete perforation collection available for design purposes.
See more

Catalog excerpts

A.7 Technical Sheet Garden Design-1

Garden Design Elements CELLON® design, classic Technical data sheet for planning, construction and execution

 Open the catalog to page 1
A.7 Technical Sheet Garden Design-2

Technical data sheet | Garden Design Elements Table of Contents General Information Material Panel Formats Data Transmission for Orders Storage and Cleaning Instructions Cutting and Drilling Guidelines Fastenings Fastening Distances for Perforated Panels Fastening Distances for Plain Panels Fasteners Substructure Panel Fixed on Primary Post Construction Panel Fixed on Secondary Profile Construction Solutions Screwed without Perforation Screwed with Perforation Screwed Two-layer with Perforation Clamped Between Post Systems Fixed to Stone Walls & Baskets with L-profile Fixed to Stone Walls & Baskets...

 Open the catalog to page 2
A.7 Technical Sheet Garden Design-3

Technical data sheet | Garden Design Elements General Information Material Our CELLON® panel is a high-pressure laminate panel (HPL Compact or solid core panel) consisting of 70% cellulose webs and 30% phenolic resin. The extremely weather and frost-resistant material is ideal for outdoor applications. Application area: Panel thickness (weight): Reaction to fire class: mounted vertically in outdoor areas (e.g. facades, balcony railings) 8mm (approx. 12kg/m²), 10mm (approx. 15kg/m²) RF2, B1 (DIN 4102-1), B-s1-d0 (EN 13501-1) The raw panels are project-specifically cut to the desired dimensions...

 Open the catalog to page 3
A.7 Technical Sheet Garden Design-4

Technical data sheet | Garden Design Elements General Information Data Transmission for Orders Please note the following when placing an order: Data Format DWG / DXF Data Cadwork 2D or 3D Data Parts lists in Excel (if only as Excel without CAD file is sent, it might result in additional work in our work preparation) Data Content and Structure Panels are drawn on a separate layer Drawing in 1:1 ratio Measurement of at least one long and short side to be able to verify the scale Boreholes (drawn as a closed circle), cut-outs, etc. are marked accordingly Special requests for grouping and/or palletisation...

 Open the catalog to page 4
A.7 Technical Sheet Garden Design-5

Technical data sheet | Garden Design Elements Fastening Distances for Perforated Panels Single-span borehole Ø 8 mm can be drawn directly in DXF/DWG file d Maximum distance according to wind load qek (wind pressure or suction) Distance borehole to edge Horizontal borehole distance Vertical borehole distance Frame without perforation Reciprocal conversion: c (adjusted) = b (max) / b (effectiv) x c (max) b (adjusted) = c (max) / c (effectiv) x b (max) The values given are guidelines and do not release you from having an object-related inspection carried out by a qualified engineer. Test results...

 Open the catalog to page 5
A.7 Technical Sheet Garden Design-6

Technical data sheet | Garden Design Elements Fastening Distances for Plain Panels Single-span borehole Ø 8 mm can be drawn directly in DXF/DWG file fixed point Fixed point 5.5 mm can be drawn directly in the DXF/DWG (only necessary for metal substructure). d Maximum distance according to wind load qek (wind pressure or suction) Distance borehole to edge Horizontal borehole distance Vertical borehole distance Reciprocal conversion: c (adjusted) = b (max) / b (effectiv) x c (max) b (adjusted) = c (max) / c (effectiv) x b (max) The values given are guidelines and do not release you from having...

 Open the catalog to page 6
A.7 Technical Sheet Garden Design-7

Technical data sheet | Garden Design Elements Fasteners Wooden Substrucure Truss-head Screw Stainless steel A2 38 mm 4.8 mm 12 mm TX20 8 mm Material: Length: Nominal diameter: Head diameter: Drives: Borehole diameter: Metal Substructure Truss-head Screw Material: Length: Nominal diameter: Head diameter: Drives: Borehole diameter: (self-drilling with sealing washer) Bi-metal (Stainless steel A2/Steel) 26 mm / 38 mm 5.5 mm 14 mm SIT® 25, TX 25 8 mm Blind Rivet Material: Length: Nominal diameter: Head diameter: Drives: Borehole diameter: Aluminium/Stainless steel A2 8-13 mm 5.0 mm 14 mm Blind rivet...

 Open the catalog to page 7
A.7 Technical Sheet Garden Design-8

Technical data sheet | Garden Design Elements Panel Fixed on Primary Post Construction If the panels are attached directly to the post construction, the post spacing is based on the maximum horizontal hole spacing according to the table on page 3. This usually results in more posts per linear meter of construction. Material and load-bearing capacity must meet the applicable Standards. Static and structural guidelines compliance is the responsibility of the installer. Profile Width two-sided cladding Elevation Plan maximal horizontal fastening distances maximal horizontal fastening distances maximal...

 Open the catalog to page 8
A.7 Technical Sheet Garden Design-9

Technical data sheet | Garden Design Elements Panel Fixed on Secondary Profile The division of the secondary profiles is based on the maximum fastening distances from the table on page 3 (here, the larger of the two fastening distances can be used if the smaller one is taken into account in the horizontal one). In this case, the post spacing is independent, can be maximized and therefore the number of posts is usually less. Material and load-bearing capacity must meet the applicable Standards. Static and structural guidelines compliance is the responsibility of the installer. Floor Plan Elevation...

 Open the catalog to page 9
A.7 Technical Sheet Garden Design-10

Technical data sheet | Garden Design Elements Construction Solutions Screwed without Perforation Floor Plan one side cladding two-sided cladding

 Open the catalog to page 10
A.7 Technical Sheet Garden Design-11

Technical data sheet | Garden Design Elements Construction Solutions Screwed with Perforation Floor Plan one side cladding two-sided cladding

 Open the catalog to page 11
A.7 Technical Sheet Garden Design-12

Technical data sheet | Garden Design Elements Construction Solutions Screwed Two-layer with Perforation Floor Plan one side cladding two-sided cladding

 Open the catalog to page 12
A.7 Technical Sheet Garden Design-13

Technical data sheet | Garden Design Elements Construction Solutions Clamped Between Post Systems Floor Plan maximal horizontal fastening distances CELLON® panels with a thickness of 10 mm are suitable for existing post systems with a corresponding mounting width. Thus, panels can be installed without the need for any additional fasteners.

 Open the catalog to page 13
A.7 Technical Sheet Garden Design-14

Technical data sheet | Garden Design Elements Construction Solutions Fixed to Stone Walls & Baskets with L-profile Floor Plan maximal horizontal fastening distances Fixed to Stone Walls & Baskets with U-profile Floor Plan maximal horizontal fastening distances

 Open the catalog to page 14