General Information
The Formboard top pine® panels are high-density fibreboards bonded with polyurethane, suitable for external applications due to their moisture resistance. They are available in 10 and 18 mm thickness and can be laser-cut to precise dimensions with a variety of color coatings. The panels should not exceed 1300 mm in smaller dimensions if coating is required.

Advantages
  • Noise absorption of over 50%.
  • Billing based on net size, minimizing wastage.
  • Precise laser cutting for custom patterns without additional cost.
  • Wide color options with excellent lightfastness.
  • Moisture-resistant and ready-to-install with drill holes and cut-outs.

Storage and Sorting
Panels must be stored in a protected location with dry PU-foam foils between them to prevent paint damage from water.

Data Submission for Orders
Orders require submission of DWG/DXF or Cadwork files with specific drawing requirements, including separate layers for Bruag panels and 1:1 scale drawings.

Custom Patterns
Custom patterns must be submitted as CAD drawings with continuous, closed contours and clear scale indications. Additional processing costs may apply.

Fixing Distances
For 18 mm thick panels, fixing distances vary based on panel width, with specific minimum and maximum distances outlined. Drill holes are typically 6 mm in diameter, and panels are fixed using façade screws or alternative fastenings provided by the contractor.

Design Notes
The design should allow for a substructure of wood or metal profiles, with fleece or felt and a 30 mm insulation layer. A cavity of 30 to 50 mm is recommended for noise absorption.

Details and Connections
Design should include a shadow gap and edge gap for efficient construction, especially in rectangular areas.

Schematic
The schematic outlines the panel setup, including fleece or felt backing, insulation, and construction frame.

Contact Information
Bruag AG, Bahnhofstrasse 8, 8594 Güttingen, Switzerland. Phone: +41 71 414 00 90, Fax: +41 71 414 00 91, Email: [email protected], Website: www.bruag.ch
See more

Catalog excerpts

1_6 Exterior Applications - Balcony Noise Attenuation-1

External Applications Balcony Noise Attenuation Balcony Noise Attenuation using Formboard top pine Panels® Version 1.0 General Information Individual panel segmentation within the following design size: The smaller dimension of the finished parts must not exceed 1300 mm, if coating is required. Our Formboard top pine® panel is a high-density fibreboard bonded with polyurethane. The material is moisture-resistant and it therefore suitable for external applications. The panels are laser-cut to exact dimensions and coated in any desired RAL/NCS S colour. The panels are available in 10 and 18 mm thickness. The Advantages at a Glance Noise absorption of more than 50% Billing of net size only (no wastage!) Precise laser cut allowing for free contour and soft edges according to submitted CAD data Over 100 perforations available from Bruag Option of custom patterns according to your CAD drawing at no additional cost Patterns can run smoothly across multiple panels Wide choice of colours (coating in NCS S Edition2, RAL) Special colours on request Moisture-resistant Colours have excellent lightfastness Ready-to-install product including drill holes and cut-outs Post-processing on site possible (holes and cut-outs) Simple installation

 Open the catalog to page 1
1_6 Exterior Applications - Balcony Noise Attenuation-2

Important Storage/Sorting Note Formboard top pine® panels must never be stored outside in unprotected flat/horizontal position during sorting. Paint damage may occur, if water remains on the panels in a horizontal position! Please store in a protected location and always place the supplied, dry PU-foam foils between the individual panels. Information on Data Submission for Orders When ordering Bruag Formboard top pine® façade panels, please note the following: The following file formats can be submitted DWG / DXF files Cadwork 2D or 3D files Information and Structure Bruag panels must be drawn...

 Open the catalog to page 2
1_6 Exterior Applications - Balcony Noise Attenuation-3

Design Notes Fixing distances Panel Width up to 1000 mm Fixing distances Width Minimum Distance (a) outer edge to centre Maximum Distance (b) centre to centre Maximum Distance (c) centre to centre The diameter of the drill holes is usually 6 mm. The panels are fixed by means of “façade screws with truss head”, diameter 4.8 mm, supplied by Bruag. Alternatively, rivets or other screw types may be used. These must be provided by the contractor and must comply with the applicable requirements. We can paint the chosen fastenings on request. Material: A2 stainless steel Length: 38 / 45 / 60 mm Nominal...

 Open the catalog to page 3
1_6 Exterior Applications - Balcony Noise Attenuation-4

Details and Connections The overall design should be at least 80 mm, ideally 100 mm. The substructure can be made using wood or metal profiles. Formboard top pine® panels are covered first with a fleece or felt and then with a layer of insulation of 30 mm thickness. The cavity behind should be 30 to 50 mm to absorb low-pitched noise. Section Design Section with Shadow Gap Section with Edge Gap For rectangular areas, it is recommended that the structure be set away from the edge on all sides by approx. 100 mm. This makes design and construction more efficient, especially inside buildings. Section:...

 Open the catalog to page 4
1_6 Exterior Applications - Balcony Noise Attenuation-5

Formboard top pine® Panel Fleece or Felt Fixed on the Back Construction Frame Wood/Metal Balcony Floor View from Below with Formboard top pine® 18 mm Perforation 50100

 Open the catalog to page 5
1_6 Exterior Applications - Balcony Noise Attenuation-6

6 Bruag AG Bahnhofstrasse 8 8594 Güttingen Switzerland [email protected] www.bruag.ch