External Applications Garden Design Landscape Gardening Features made of CELLON®-Panels Version 1.0 General Information Individual panel segmentation within the following design sizes: For panels without perforation, the maximum width is 1300 mm. Our CELLON®-panel is a Compact High-Pressure Laminate Panel (HPL) consisting of 70% cellulose sheets and 30% phenolic resin. The weather-resistant material is ideally suited for external applications such for balcony infill, separation and screening. The unprocessed boards are manufactured exactly as required for each individual project using laser technology. The panels are thus pre-cut to the exact dimensions (incl. drill holes) and with the desired perforations for the specific construction site. The panels are coated after cutting. Depending on the perforation and the distance between the fixing points, 8 or 10 mm thick panels are used.

Open the catalog to page 1
1_5 Exterior Applications - Garden Design Technical Sheet - 2

The Advantages at a Glance The unlimited selection of perforation patterns and colours provide a large variety of design options, this way the degree of transparency can be selected freely Precise laser cut allowing for free contour and soft edges according to submitted CAD data Over 100 perforation available from Bruag Option of custom patterns according to your CAD template at no additional cost Perforations can run smoothly across multiple panels Wide choice of colours (coating according to NCS S Edition 2, RAL, Bruag Alu or IGP) Special colours on request Moisture-resistant,...

Open the catalog to page 2
1_5 Exterior Applications - Garden Design Technical Sheet - 3

Panels without Perforation Fixing Distances Panel without Perforation The diameter of the drill holes is usually 8 mm (fastener + min. 2 mm). The panels are fixed by means of "self-tapping fagade screws with hexagonal head and washer”, diameter 4.8 mm, supplied by Bruag. Alternatively, rivets or other screw types may be used. These must be provided by the contractor and must comply with the applicable requirements. We can paint the chosen fastenings on request. COUNTERSUNK SCREWS MUST NOT BE USED! Material: A2 stainless steel Length: 38 mm Nominal Diameter of Screw: 4.8 mm Head Diameter: 16...

Open the catalog to page 3
1_5 Exterior Applications - Garden Design Technical Sheet - 4

Panels with Perforation Fixing Distances Panel with Perforation A central, vertical support must be provided for panel of widths 1500 mm or larger in order to maintain secure fixing. Width of support at least 30 mm. If several panels are connected, 4-6 mm must be allowed for the panel joint. The support for the screw connection in this case must be at least 70 mm.

Open the catalog to page 4
1_5 Exterior Applications - Garden Design Technical Sheet - 5

Design Alternatives Screening Elements Mounted on Concrete Support Posts CELLON® screening elements require a stabilising substructure, on which they can be screwed to. Alternatively, the structures can also be covered on both sides and additionally equipped with a sound absorber suitable for external application. Especially alongside busy roads, this provides effective and attractive sound protection. Frame Covered on one Side Perforation 10100 Frame Covered on two Sides with Absorber Perforation 10100 Potential design with 40 mm sound absorber as intermediate layer

Open the catalog to page 5
1_5 Exterior Applications - Garden Design Technical Sheet - 6

Screening Elements between Walls and Gabions Closed or perforated CELLON® panels can be placed between existing structures to break up the overall appearance. Smooth panels are available in all RAL/NCS S colours up to maximum of 1300 mm width. Perforated elements may be installed up to a width of 1800 mm. The maximum span depends on the panel thickness and perforation. It is important to that the CELLON® panels have space for expansion. This means that suitable joints must always be provided for wall connections or joints. Moreover, countersunk screws must not be used. The hole diameter in...

Open the catalog to page 6
1_5 Exterior Applications - Garden Design Technical Sheet - 7

Screening Elements between Post Systems CELLON® panels with a thickness of 10 mm are suitable for existing post systems, if they are installed with suitable gaps. This means that panels can be inserted without additional fixing materials. CELLON® 10 mm Perforation 50112 Section Post Model www.windundsichtschutz.ch

Open the catalog to page 7
1_5 Exterior Applications - Garden Design Technical Sheet - 8

Planters Planters and Decorative Elements Flower boxes made from CELLON® are suitable as non-fixed screening. The rear can be customised and designed as required. Maximum Dimensions Width: CELLON® 10 mm Perforation 10100 scaled x 1.5 Other designs and decorative elements are also possible. We are available for individual inquiries.

Open the catalog to page 8