Introduction to Power Systems on Bretford Tables and Carrels

This document provides a step-by-step guide for determining the number of circuits required for powering Bretford tables and carrels. It is designed for individuals unfamiliar with electrical systems but responsible for specifying such systems when ordering furniture.

Steps to Determine Circuit Requirements:

  1. Identify Amps: Locate the amps on the device's faceplate or owner's manual. Example: INPUT: 120 V ˜ 1.8 A.
  2. Calculate Total Amps: Add the amps for each device in the power series. Example: 3 amps per computer and monitor, 9 amps for a printer.
  3. Divide by 16: Circuits are restricted to 16 amps for continuous use per the National Electric Code.
  4. Determine Number of Circuits: Round up the result to the nearest whole number to find the required circuits. If more than 4, reduce power usage or create a new system.
  5. Repeat for Each Series: Apply these steps for each power series in use.

Electrical System Overview:

Bretford's 8-wire, 4-circuit system uses Duplex receptacles to manage power distribution. Circuits 1, 2, and 3 share a common ground, while Circuit 4 has a separate ground, suitable for sensitive equipment.

Examples of Circuit Configurations:

  • 2-Circuit System: Requires specific Duplexes along the system. Example: 4 TransTables, 4 PowerTrak Raceways, 4 Power Harnesses, 4 Duplex Circuits 1 and 2, 3 Jumpers, 1 Hardwire Power Feed.
  • 4-Circuit System: Example: 5 TransTables, 1 Pie Top, 5 PowerTrak Raceways, 5 Power Harnesses, 3 Duplex Circuits 1 and 2, 2 Duplex Circuits 3 and 4, 4 Jumpers, 1 Hardwire Power Feed.

Additional Information:

All powered tables include data/communication raceways. PowerTrak Raceway provides a separate communication channel and meets Category 5 requirements.

Alternatives and Accessories:

  • Powerhouse™: A surface-mounted power and data box for tabletop access, available with a 20-foot or 6-foot grounded electrical cord.
  • Surge Protected Simplex: Replaces a Duplex with a surge-protected outlet.
  • Surge Protected Power Strip: A four-outlet strip with 1 circuit capability, mounts below the tabletop.

For further assistance, contact Bretford Manufacturing, Inc. at their provided contact details.

See more

Catalog excerpts

Power 101-1

POWER SYSTEMS 101 An Intr oductionto UsingPower on Br etfor T d ables and Carr els

 Open the catalog to page 1
Power 101-2

How to Determine the Quantity of Circuits Your Power Series Requires STEP 1 Figure out how many amps you will be running. An amp is a unit of measure that tells how much electricity a machine is drawing from an electrical system. On your computer or electrical device, locate the faceplate that describes the machine’s technical features. The amps are usually displayed like this: INPUT: 120 V 1.8 A. If you cannot find this ˜ information on the machine, it may be located in the owner’s manual. Calculate the total number of amps per powered series. A powered series is the total number of amps from...

 Open the catalog to page 2
Power 101-3

Becoming Familiar with Electrical Systems Most people are intimidated or ner vous when dealing with electrical issues. This step-by-step guide is for people who may not be familiar with electrical systems, but are responsible for specifying such systems when or dering furniture. It provides a basic understanding of an 8-wir e, 4-circuit (20 amp per circuit) system and ho w to specify it on Br etford furniture. By following the simple steps outlined her e, one can easily determine ho w many circuits are required to ensure safety when using electrical equipment. This information is intended to...

 Open the catalog to page 3
Power 101-4

Applying Steps 1-5 to Your Bretford Tables and Carrels Now that we know how many circuits each powered series will need, let’s see how it applies to different types of Bretford tables and carrels. Bretford’s 8-wire, 4-circuit system uses Duplex receptacles (each duplex has two power outlets) to determine from which circuit the electrical equipment will draw power. The receptacles are marked 1, 2, 3 or 4 to designate the circuit that is activated when it is installed into the power harness. Circuits 1, 2 and 3 all share a common ground while circuit 4 has a separate ground and a neutral wire....

 Open the catalog to page 4
Power 101-5

Presentation Environments® PowerTrak™ Raceway If your system requires 2 circuits, specify Duplexes 1 and 2 along the entire system to access those specific circuits. Here is an example of what a 2-circuit system will require: (4) 30″D x 60″L TransTables (4) 60″L PowerTrak Raceway (4) 60″L Power Harness (4) Duplex Circuit 1 (4) Duplex Circuit 2 (3) Jumpers (1) Hardwire Power Feed Here is an example of what a 4-circuit system will require: (5) 30″D x 72″L TransTables (1) 90° Pie Top (5) 72″L PowerTrak Raceway (5) 72″L Power Harness (3) Duplex Circuit 1 (3) Duplex Circuit 2 (2) Duplex Circuit 3...

 Open the catalog to page 5
Power 101-6

Presentation Environments® Powered Conference Tables If your system requires 2 circuits, specify Duplexes 1 and 2 along the entire system to access those specific circuits. Here is an example of what a 2-circuit system will require: (1) 48″D x 144″L Racetrack Conference Room Table with two (2) Power Doors (1) 144″L Conference Table Power Harness Pack (2) Duplex Circuit 1 (2) Duplex Circuit 2 Here is an example of what a 4-circuit system will require: (1) 54″D x 192″L Racetrack Conference Room Table with four (4) Power Doors (1) 192″L Conference Table Power Harness Pack (2) Duplex Circuit 1 (2)...

 Open the catalog to page 6
Power 101-7

Legacy™ Library System Technology Tables If your system requires 2 circuits, specify Duplexes 1 and 2 along the entire system to access those specific circuits. Here is an example of what a 2-circuit system will require: (2) 30″D x 72″L Technology Tables (2) 72″L Power Harness Pack (4) Duplex Circuit 1 (4) Duplex Circuit 2 (1) Jumper (1) Hardwire Power Feed Here is an example of what a 4-circuit (shown below) system will require: (4) 30″D x 72″L Technology Tables (4) 72″L Power Harness Pack (4) Duplex Circuit 1 (4) Duplex Circuit 2 (4) Duplex Circuit 3 (4) Duplex Circuit 4 (3) Jumpers (1) Hardwire...

 Open the catalog to page 7
Power 101-8

Legacy™ Library System Technology Carrels If your system requires 2 circuits, specify Duplexes 1 and 2 along the entire system to access those specific circuits. Here is an example of what a 2-circuit single-faced carrel system will require: (1) 36″W Single-Faced Technology Carrel Starter (1) 36″W Single-Faced Technology Carrel Add-On (2) 36″W Power Harness (2) Duplex Circuit 1 (2) Duplex Circuit 2 (1) Hardwire Power Feed Here is an example of what a 4-circuit single-faced carrel system will require: (1) 36″W Single-Faced Technology Carrel Starter (7) 36″W Single-Faced Technology Carrel Add-On...

 Open the catalog to page 8
Power 101-9

Alternatives and Accessories for Power For applications with smaller power requirements, Bretford’s tables and carrels can also be specified with a softwire electrical system. Bretford offers the following accessories for softwire systems: Powerhouse™ This surface-mounted power and data box secures into any grommet hole on Bretford training tables, Legacy tables and carrels, and provides tabletop access to power and data. Each Powerhouse comes with a Duplex electrical outlet, data plates that can accommodate the Amp 110 Connect Series data receptacles, and either a 20-foot or 6-foot grounded...

 Open the catalog to page 9
Power 101-10

Copyright 1997 Bretford Manufacturing, Inc. Bretford and Presentation Environments are registered trademarks. PowerTrak, Legacy and Powerhouse are trademarks of Bretford Manufacturing, Inc.

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.