1. Catalogs
  2. Breeze Controls
  3. Breeze TV01 Datasheet

Breeze TV01 Datasheet

Breeze TV01 Datasheet
1 / 18 PagesView full catalog

Breeze TV01 Datasheet

Product catalog summary
Information about this Manual
This section highlights the necessity of thoroughly reading the manual before using the device. It includes essential information on the device's intended use and safety precautions. Users are encouraged to retain the manual for future reference and to pass it on if the device is transferred to others.
Product Description
The TV01 Thermostatic Radiator Valve (TRV) is a self-regulating valve that controls room temperature by adjusting the flow of hot water to radiators. It allows temperature settings between 5-30℃ and can save over 15% of energy. The device is compatible with common radiator valves and includes a boost function for rapid heating.
Device Overview
This section provides a visual and descriptive overview of the device's components and layout.
Start-up
Before we get started: The device requires 2 AA batteries, and the temperature is displayed in Celsius.
Inserting(replacing) batteries: Instructions for battery installation and replacement, including battery life and replacement indicators.
Set date and time: Steps to set the date and time after battery installation, including adaptive installation instructions.
Installation of the Radiator Thermostat
Instructions for installing the thermostat without draining heating water or using special tools. It includes compatibility with various valve types and brands, with specific steps for different valve models like Danfoss and Giacomini.
Interface Screen
Details on the LCD screen display and initial configuration steps.
Product Features
Auto Mode: Temperature control according to a set heating profile.
Manual Mode: Allows manual temperature setting.
Holiday Mode: Maintains a set temperature during absences.
Open Window Detection: Stops heating when a sudden temperature drop is detected.
Offset Temperature: Adjusts for temperature distribution variations.
Eco and Comfortable Temperature: Quick switching between preset temperatures.
Child Lock: Prevents unintended changes to settings.
Anti-Freezing Mode: Ensures indoor temperature does not drop below 8℃.
Heating Stop (Power Saving) Mode: Prolongs battery life by fully closing the valve.
Anti-Calcification (Descaling) Protection: Prevents valve calcification.
Boost: Provides rapid heating by fully opening the valve for 5 minutes.
Setting
Instructions for configuring various settings such as date, week programming, open window detection, and temperature settings.
Low Battery
Information on battery replacement indicators.
Reset
Steps to reset the device to factory settings.
Troubleshooting and Maintenance
Guidance on resolving common issues and maintaining the device.
Technical Data
Specifications and technical details of the device, including battery type, lifespan, operating temperature range, protection rating, dimensions, and weight.
Package Contents
List of items included in the package, such as the radiator thermostat, batteries, adapters, a screw for the adapter, and a user manual.
Instructions for Disposal
Proper disposal methods for the device and its components, emphasizing the use of local collection points for electronic equipment and battery disposal. The device is not a toy and should be kept away from children.
See more

Catalog excerpts

Breeze TV01 Datasheet-1

TV01 Thermostat Radiator Valve

 Open the catalog to page 1
Breeze TV01 Datasheet-2

1. Information about this manual 5. Installation of the radiator thermostat 5.1 Unscrew your existing radiator thermostat 5.3 Danfoss RAVL Valve 7.4 Open Window Detection 7.9 Heating Stop (Power Saving) Mode 7.10 Anti-Calcification (Descaling) Protection 8.2 Week Programming Stage

 Open the catalog to page 2
Breeze TV01 Datasheet-3

Please read this manual completely and carefully before starting to use the device. The manual contains important information about the intended use of the device. Especially observe the safety notes. Keep the manual for later consultation. If you hand over the device to other persons for use, please hand over the operating manual as well. Thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator. With the TRV TV01 you can conveniently adjust the room temperature...

 Open the catalog to page 3
Breeze TV01 Datasheet-4

4.2 Inserting(replacing) batteries --Pull off the battery compartment cover on the underside of the device. --Insert 2 new LR6(mignon/AA) batteries in the battery compartment, making sure they are the right way round. --Reattach the battery compartment cover and latch it into place. The service life of new alkaline batteries is approximately 2 years. A battery symbol( ) on the display indicates that the batteries need to be replaced. After removing the empty batteries, wait approx. 1 minute before inserting the new ones. This device does not support operation with rechargeable batteries. 4.3...

 Open the catalog to page 4
Breeze TV01 Datasheet-5

If the adapting runs is initiated before installation, press Boost button and the motor travels back to the ' InS ' position. If an error message(F1,F2,F3) is displayed, press the Pair/Boost button and the motor similarly travels back to the ' InS ' position. The radiator thermostat is easy to install and can be done without draining heating water or intervening in the heating system. No special tools are required, nor does the heating have to be switched off. The ring nut attached to the radiator thermostat can be used universally and without accessories for all valves with a thread size of...

 Open the catalog to page 5
Breeze TV01 Datasheet-6

5.3 Danfoss RAVL Valve --Check the © is active. --The valve bodied have elongated notches around their circumference, which ensure that the adapter is properly seated when it snaps on: snap on the adapter completely,so that the pins inside the adapter are lined up with the notches on the valve. --Install the adapter,Plane A is aligned with Plane B. --Install the round tube into the device. --Install the device.

 Open the catalog to page 6
Breeze TV01 Datasheet-7

5.4 Danfoss RAV Valve --Check the is © active --The valve bodied have elongated notches around their circumference, which ensure that the adapter is properly seated when it snaps on: snap on the adapter completely,so that the pins inside the adapter are lined up with the notches on the valve. --Install the adapter,Plane A is aligned with Plane B. --Union nut. --Install the device. 5.5 Danfoss RA Valve --Rotate the thermostat dial to the maximum value, "N" Align Dial. --Check the is © active. --The valve bodied have elongated notches around their circumference, which ensure that the adapter is...

 Open the catalog to page 7
Breeze TV01 Datasheet-8

5.6 28x1.5mm 1. Select the length of the ejector rod according to the following brands or valve sizes, and the size of ejector rod is 15 / 17 / 19 / 24mm. 2. To install the ejector rod with the correct size into the hole. 3. To install the adapter onto M28 * 1.5 valve;

 Open the catalog to page 8
Breeze TV01 Datasheet-9

5.7 Giacomini 1. To install the adapter onto the Giacomini valve in the correct direction;2. To install the GIA ejector rod into the hole ; 5.8 Caleffi 1. Open the valve flow to the maximum, as shown in pic 1;2. To install the adapter onto the Caleffi valve in the correct direction ;

 Open the catalog to page 9
Breeze TV01 Datasheet-10

5.9 Use the Ejector rod Due to the dimensional and assembly tolerance of the metal valve, it may result in the following situations: 1. When the device is failure, F2 is displayed 2. The metal valve cannot be fully closed and is kept heating all the time Handling method : Please use the ejector rod 1.6mm (1)first, if the above two situations still exist, try to use the ejector rod2.6mm(2) instead.

 Open the catalog to page 10
Breeze TV01 Datasheet-11

6. Interface screen When you see the LCD screen is showing information as below, the radiator thermostat is ready for configuration. If not, please uninstall and re-install the batteries and redo step 4. 7. Product features 7.1 Auto Mode In automatic mode, the temperature is controlled in accordance with the set heating profile. Manual changes are activated until the next point at which the profile changes. Afterwards, the defined heating profile will be activated again. To activate the automatic mode, please proceed as follows:

 Open the catalog to page 11
Breeze TV01 Datasheet-12

Press the mode button to select ( Default temperature 7.2 Manual Mode In manual mode, the temperature is controlled in accordance with the current temperature set via ‘+/-’ button. The temperature remains activated until the next manual change. To activate the manual mode, please proceed as follows: --Press the mode button to select( --Default temperature: 20℃. --Temperature range: 5-30℃, step: 0.5 ℃. 7.3 Holiday Mode When you go out or go to a party, you will use the holiday mode. The holiday mode will automatically start at the set time starting point and run the holiday temperature. When the...

 Open the catalog to page 12
Breeze TV01 Datasheet-13

--Set the desired offset temperature using ‘+/-’ button and confirm with the menu button. The comfort and Eco temperature button makes switching between comfort and Eco temperature simple and user friendly. These have been set at the factory at 21°C (comfort temperature) and 17°C (Eco temperature). They can be adjusted as follows: Press menu button to select comfortable temperature (’•' ) or Eco temperature( ^ ). Even in auto mode, the temperature can be changed at any time using the button. It will then remain the same until the next point at which the program changes. Operation of the device...

 Open the catalog to page 13
Breeze TV01 Datasheet-14

The equipment will automatically run for a period of time every week to prevent calcification of the valve. 7.11 Boost Sometimes people go home earlier than usual, and the rapid heating function will make you feel the warmth of the room faster. When activated, the valve will be fully opened for 5 minutes. The heating of a room takes longer than 5 minutes, but the heat given off by the radiator can be felt immediately. --Press the boost button to activate the boost function. --The remaining time for the function will be counted down in seconds(‘299’ to ‘000’). --After these 5 minutes have elapsed,...

 Open the catalog to page 14

All Breeze Controls catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.