panl-line™ building system a complete guide including specifications and accessories for a wide variety of small buildings • • • • • • • • • • • • • • • Field Offices Generator Buildings Guard Houses Relocatable Classrooms Waste Water Treatment Buildings HVAC Penthouses Pump Houses Industrial Storage Buildings Drum Storage Buildings Instrument Enclosures Electrical Substations Pipeline Measure Stations Fire Protection Equipment Buildings Motor Control Centers and more!
Open the catalog to page 1panl-line™ building system guide This manual is designed to give you the technical information necessary to specify a Panl-Line building system to meet your exact requirements. Starting with the “General Specifications” shown below, you can then add the Building and Accessory specifications needed for your building project. This complete guide includes specifications and accessories for a multitude of building needs including: Field Offices Guard Houses HVAC Penthouses Pump Houses Valve Houses Electric Substations Generator Buildings Relocatable Classrooms Waste Water Treatment Buildings...
Open the catalog to page 2panl-line™ commentary and specifications design commentary Panl-Line buildings are designed in accordance with nationally-recognized building codes including: The National Building Code. Standard Building Code. Uniform Building Code. National Building Code of Canada (NBCC). International Building Code and state or local Building codes as applicable by ordinance. To allow us to furnish a building system to meet your specific needs, please specify: 1. - Applicable Building Code including year. 2. - The roof live load in pounds per square foot (PSF). 3. - The ground snow load in pounds per...
Open the catalog to page 3panl-line™ 1 building system & specifications 12 1/8" 8" ROOF PANEL EAVE HEIGHT WALL CAP WALL PANEL CONTOUR EAVE TRIM (OPTIONAL) SIDE TRIM SECTION AT EAVE ( HIGH SIDE ) HEIGHTS LENGTHS ROOF SLOPE CONTOUR GUTTER (OPTIONAL) STANDARD SIZES ROOF SLOPE ROOF PANEL BASE FLASHING ANCHOR BOLT CORNER DETAIL ROOF PANEL PANEL CLOSURE BASE CHANNEL RIB BOLT WALL PANEL CONTOUR WALL PANEL GABLE TRIM (OPTIONAL) Building System 7.1 The building shall be a self framing design utilizing the roof and wall panels as the primary structural supporting components. 7.2 The transmission of horizontal wind loads shall...
Open the catalog to page 4panl-line™ 2 specifications Panl-Line 2 buildings up to 24’ in length do not require intermediate structural frames and the “Self Framing” specification should be used for these lengths. Over 24’ long buildings require structural frames on 12’, 16’ 20’, or 24’ spacing and the “Structural Framed” specification should be used for all buildings over 24’ long. Building System (Self Framing) 7.1 The building shall utilize the structural strength of the interlocking wall system to support the building vertical live load and wind loads and shall not require column, rafter or wall girt supporting...
Open the catalog to page 5PANL-LINE™ 2 BUILDING SYSTEM SELF FRAMING BUILDING
Open the catalog to page 6panl-line™ 2 building system 8" WALL PANEL PANEL CLOSURE BASE CHANNEL BASE FLASHING ANCHOR BOLT ROOF PANEL RAKE TRIM WALL PANEL BOLTS RAFTER BEAM PURLIN CLIP RAKE GIRT PURLIN TO FRAME DETAIL D SECTION AT EAVE PURLIN SPACING BLDG. WIDTH 12' 16' 20'
Open the catalog to page 7PANL-LINE HOLLOW METAL DOORS NARROW LIGHT HALF GLASS Louver, 22" Wide x 20" High (Optional) BASE CHANNEL
Open the catalog to page 8panl-line™ personnel door specifications personnel door specifications Door shall be 1-3/4” thick full flush type. Door panels shall be nominal 20-gauge galvanized steel welded to nominal 16-gauge flush-mounted end channels. The door shall be manufactured in accordance with ANSI/SDI 100, Grade 1, Model 1 Level C. (SELECT ONE OF THE FOLLOWING CORE SPECIFICATIONS) Door leaf core shall be resin impregnated honeycomb laminated to the door panels. Calculated “U” value shall be .041 (R=2.4), and sound transmission shall be STC 30 per ASTM E90-70 and E 412-73 tests. OR Door leaf core shall be...
Open the catalog to page 9panl-line™ wall accessories OVERHEAD DOOR OPENINGS DOOR HEIGHT PANEL CLOSURE PANEL CONNECTOR HEAD PANEL HEAD ASSEMBLY HEAD ASSEMBLY Full Height Open NOTE: BE SURE TO CHECK HEADROOM REQUIRED FOR DOOR BEING USED IN THE OPENING ! Door Width Door Height 1'-0" INCREMENTS STARTING 1'-0" BELOW EAVE HEIGHT. HEAD PANEL The building manufacturer shall supply all necessary framing and connections to structurally replace the panels removed by any wall opening. EXTERIOR ELEVATION (2'-8" SHOWN) PANEL OPENING NOTE: Customer to specify dimensions 'A' and 'B' SILL PANEL Blades shall be pivoted on 1/2”...
Open the catalog to page 10HEAD PANEL Standard Sill Height If Not Specified PANEL CONNECTOR Window Width 'A' EXTERIOR ELEVATION MOVABLE LITE FIXED LITE WALL PANEL PANEL CLOSURE HORIZONTAL SLIDING WINDOWS SILL PANEL PANEL CLOSURE WINDOW JAMB SECTION 'B'-'B' Sliding Windows Windows shall meet or exceed ANSI/AAMA 101 and AAMA 1302.5 standards. All window framing sections shall be made of 6063-T5 extruded aluminum color finished in (WHITE, BRONZE) (SELECT ONE) factory baked enamel. Windows shall be factory assembled and factory glazed with (SELECT ONE FROM LIST BELOW). 1/2” clear insulated glass 1/4” clear polished wire...
Open the catalog to page 11panl-line™ roof vents/curbs TURBINE VENTILATOR Turbine ventilator shall be 12” diameter capable of exhausting 580 CFM of air at a 5 MPH wind velocity. Ventilators shall be made of galvanized steel with aluminum external bracing. Upper rotary bearings shall be bronze oiless and lower bearings shall be thrust type ball bearings. ROOF JACK ROOF PANEL STATIONARY VENTILATOR Stationary ventilator shall be 12” diameter capable of exhausting 495 CFM of air with a 20 degree F temperature differential, 10 MPH wind velocity and a 10’ ventilator height. 11 -p" Ventilators shall be fabricated from...
Open the catalog to page 12panl-line™ insulation and ceiling fiberglass roof insulation FACED FIBERGLASS INSULATION FACED FIBERGLASS INSULATION ROOF PANEL WALL PANEL The “U” value through the insulated roof shall be (SELECT ONE FROM CHART ‘A’) BTUs per square foot when measured in accordance with the “Zone Method” contained in ASHRAE “Handbook of Fundamentals” 1981 edition. Continuous Continuous Continuous Calculated system "U" value 0.10, 0.08 & 0.05 respectively (ASHRAE zone method) therma - roof insulation ROOF PANEL WALL PANEL Insulation shall have a maximum UL flame spread rating of 25, fuel contributed rating...
Open the catalog to page 13All BlueScope Steel catalogs and technical brochures
-
CUSTOM ORB® CUSTOM BLUE ORB®
8 Pages
-
Flatdek
6 Pages
-
SPANDEK®
6 Pages
-
Spanrib
6 Pages
-
BONDEK®
12 Pages
-
Rainwater solutions
12 Pages
-
Custom ORB accent 35
6 Pages
-
Custom ORB accent 21
6 Pages
-
LysaghtTopspanMay2013
20 Pages
Archived catalogs
-
Shed Colorbond
2 Pages
-
Fencing Colorbond
6 Pages
-
Guttering Colorbond
4 Pages
-
Zincalume
5 Pages
-
Progect so case
16 Pages
-
Curvers and Contours
6 Pages
-
Fencing
6 Pages
-
Colours fo roofing
2 Pages
-
Colorbond®steel protects
2 Pages
-
Colorbond®
2 Pages