video corpo

BLÜCHER® Europipe Below Ground
12Pages

{{requestButtons}}

Catalog excerpts

BLÜCHER® Europipe Below Ground - 1

Drainage systems for below ground STAINLESS STEEL DRAINAGE SYSTEMS

Open the catalog to page 1
BLÜCHER® Europipe Below Ground - 3

BELOW GROUND BLÜCHER® EuroPipe is the ideal drainage system for belowground use. The stainless steel systems offers the specifier and installer a metallic push-fit, lightweight and cost effective drainage system for foul and storm water drainage. Same pipe system below and above ground The piping system comes in stainless steel grades AISI 316L and AISI 304. For below ground, grade 304 might be used, but BLÜCHER recommends the use of 316L because the risk of corrosion, caused by an aggressive environment, is significantly reduced or eliminated entirely by choosing the molybdenum stainless...

Open the catalog to page 3
BLÜCHER® Europipe Below Ground - 5

PIPES AND FITTINGS BLÜCHER® EuroPipe includes a complete product range of pipes, bends, branches, access fittings and rodding eyes in standard dimensions Ø110, 125, 160, 200, 250 mm and standard lengths ranging from 0,15 m up to 6 m. BLÜCHER recommends the use of minimum Ø110 mm for below-ground installations. Also local regulations may require the use of minimum Ø110 mm. Customised items Customised items are available on request. Tools Our electric or manual BLÜCHER® pipe cutter is used to cut pipes to lengths and bevel pipe ends for jointing. SELECTED PIPES AND FITTINGS Description...

Open the catalog to page 5
BLÜCHER® Europipe Below Ground - 6

RODDING EYES AND GASTIGHT DRAINS The BLUCHER® range for below-ground applications includes a complete range of nodding eyes and gastight drains. More drains are available in our standard product Customised items Customised items are available on request. RODDING EYES AND GASTIGHT DRAINS Description Outlet Item No. Handling Rodding eyes with 10 mm grate Gastight industrial drains with 10 mm grate for concrete Gastight industrial drains with 10 mm grate for epoxy Gastight upper parts with 10 mm grate for concrete Gastight upper parts with 10 mm grate for epoxy screw/vacuum handle screw/vacuum...

Open the catalog to page 6
BLÜCHER® Europipe Below Ground - 7

ACCESS COVERS BLÜCHER® access covers are produced from 2 mm stainless steel providing a high level of stability and durability. The access covers are designed with “eyes” and a taper fit for easy lifting and access. You can lift the covers manually or choose to use lifting equipment. A sealing ring below the lid prevents smell from spreading and ensures a water-tight solution.n The access covers fulfill the standard EN 124. The cover can be mounted/fitted to the frame, and concrete anchors are pre-mounted for safe construction. Use of concrete C35/C45 guarantees the load class mentioned...

Open the catalog to page 7
BLÜCHER® Europipe Below Ground - 8

INSTALLATION Filling around the pipe Filling around the pipe can only start when the position of the pipe has been checked and approved. Compression Avoid tipping the filling directly onto the pipe. If a machine is used for compression, the equipment’s own weight and impact force must be adapted to conditions. The filling should be compressed to at least 93%. Filling the excavation Soil from the excavation can be used for filling, but larger stones and blocks are not to be used. Compression of the filling material outside reinforced areas is not necessary if the settling will not cause...

Open the catalog to page 8
BLÜCHER® Europipe Below Ground - 9

Pipes cast in raft foundations Piled ground expected to settle 38 mm water gauge air test Pipe brackets and tie rods to hang from slab Compact surround or use self-compacting backfill (comp. fraction <0,2) Backfill with free-flowing self-compacting material Pour slab and catch tie rods

Open the catalog to page 9
BLÜCHER® Europipe Below Ground - 10

MINIMUM SOIL COVERING VALUES FOR MINIMUM AND MAXIMUM SOIL COVERING Where min. values are given in the tables for soil covering, also the frost-free depth must be taken into account. No max. values are specified for normal and heavy traffic as the max value is over 12 m under all conditions. BLÜCHER® EUROPIPE - MINIMUM SOIL COVERING (METRES) ACCORDING TO DS 430: - pipe below water table (terrain = water table) - soil compressed to 93% SP -y = 8 kN/m³ Ø110 mm Density (kN/m³) Traffic Normal Heavy min. (m) min. (m) - pipe above water table - soil compressed to 93% SP Ø110 mm Density (kN/m³)...

Open the catalog to page 10
BLÜCHER® Europipe Below Ground - 11

EASY INSTALLATION Electric pipe cutter 1. Cutting Use BLÜCHER® manual or electric pipe cutter to cut the pipes. The pipes can then be installed without subsequent finishing. NB! Fittings are not to be cut. 2. Check of lip seal Check that the lip sealing ring is correctly installed in the socket. 3. Cleaning If necessary, clean lip seal and socket before jointing. Apply lubricant to the spigot. 4. Jointing Joint the pipes with a turning movement. A detailed user guide is provided when buying or hiring an electric pipe cutter. Manual pipe cutter Jointing of socket and spigot end 2 Insertion...

Open the catalog to page 11
BLÜCHER® Europipe Below Ground - 12

At BLÜCHER® more than 300 employees create an annual turnover of more than 50 million euro. Through know-how, dedicated service and common sense we develop, produce and market high quality stainless steel drainage solutions for customers within the housing, Find your local BLÜCHER® specialist at www.blucher.com 22502 - CS Grafisk . 2000.08.08        Errors and omissions expected        Copyright by BLÜCHER commercial, industrial and marine sectors all over the world.

Open the catalog to page 12

All BLÜCHER Metal catalogs and technical brochures

  1. 755.573.110

    1 Pages

  2. 110.300.050

    1 Pages

  3. 110.300.075

    1 Pages

  4. HygienicPro®

    32 Pages

  5. Main catalog

    203 Pages

  6. WATERLINE

    3 Pages

Archived catalogs