video corpo

BLÜCHER® Below Ground Application brochure
12Pages

{{requestButtons}}

Catalog excerpts

BLÜCHER® Below Ground Application brochure - 1

K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S Drainage systems for below ground

Open the catalog to page 1
BLÜCHER® Below Ground Application brochure - 3

BLÜCHER® EuroPipe is the ideal drainage system for belowground use. The stainless steel systems offers the specifier and installer a metallic push-fit, lightweight and cost effective drainage system for foul and storm water drainage. Same pipe system below and above ground The piping system comes in stainless steel grades AISI 316L and AISI 304. For below ground, grade 304 might be used, but BLÜCHER recommends the use of 316L because the risk of corrosion, caused by an aggressive environment, is significantly reduced or eliminated entirely by choosing the molybdenum stainless steel type...

Open the catalog to page 3
BLÜCHER® Below Ground Application brochure - 5

Straight pipe 110 1000 811.100.110 S Straight pipe 110 1500 811.150.110 S Straight pipe 110 2000 811.200.110 S Straight pipe 110 3000 811.300.110 S Straight pipe 110 4000 811.400.110 S Straight pipe 110 5000 811.500.110 S Straight pipe 110 6000 811.600.110 S Straight pipe 125 1000 811.100.125 S Straight pipe 125 1500 811.150.125 S Straight pipe 125 2000 811.200.125 S Straight pipe 125 3000 811.300.125 S Straight pipe 125 4000 811.400.125 S Straight pipe 125 5000 811.500.125 S Straight pipe 125 6000 811.600.125 S Straight pipe 160 1000 811.100.160 S Straight pipe 160 1500 811.150.160 S...

Open the catalog to page 5
BLÜCHER® Below Ground Application brochure - 6

RODDING EYES AND GASTIGHT DRAINS The BLÜCHER® range for below-ground applications includes a complete range of rodding eyes and gastight drains. More drains are available in our standard product catalogue or at www.blucher.com. Customised items Customised items are available on request. Description Outlet Item No. Handling Rodding eye 150 Ø75 144.150.075 S w/nipple Rodding eye 150 Ø75 144.155.075 S screw/vacuum handle Rodding eye 150 Ø110 144.150.110 S w/nipple Rodding eye 150 Ø100 144.155.110 S screw/vacuum handle Rodding eye 200 Ø160 144.200.160 S w/nipple Rodding eye 200 Ø160 144.205.160...

Open the catalog to page 6
BLÜCHER® Below Ground Application brochure - 7

ACCESS COVERS BLÜCHER® access covers are produced from 2 mm stainless steel providing a high level of stability and durability. The access covers are designed with “eyes” and a taper fit for easy lifting and access. You can lift the covers manually or choose to use lifting equipment. A sealing ring below the lid prevents smell from spreading and ensures a water-tight solution.n The access covers fulfill the standard EN 124. The cover can be mounted/fitted to the frame, and concrete anchors are pre-mounted for safe construction. Use of concrete C35/C45 guarantees the load class mentioned...

Open the catalog to page 7
BLÜCHER® Below Ground Application brochure - 8

INSTALLATION Filling around the pipe Filling around the pipe can only start when the position of the pipe has been checked and approved. Compression Avoid tipping the filling directly onto the pipe. If a machine is used for compression, the equipment’s own weight and impact force must be adapted to conditions. The filling should be compressed to at least 93%. Filling the excavation Soil from the excavation can be used for filling, but larger stones and blocks are not to be used. Compression of the filling material outside reinforced areas is not necessary if the settling will not cause...

Open the catalog to page 8
BLÜCHER® Below Ground Application brochure - 9

9 Pipes cast in raft foundations Piled ground expected to settle • Set to line and level on 50 mm bed • 38 mm water gauge air test • Pipe brackets and tie rods to hang from slab • Compact surround or use self-compacting backfill (comp. fraction <0,2) • Backfill with free-flowing self-compacting material • Pour slab and catch tie rods

Open the catalog to page 9
BLÜCHER® Below Ground Application brochure - 10

10 MINIMUM SOIL COVERING Where min. values are given in the tables for soil covering, also the frost-free depth must be taken into account. No max. values are specified for normal and heavy traffic as the max value is over 12 m under all conditions. VALUES FOR MINIMUM AND MAXIMUM SOIL COVERING BLÜCHER® EUROPIPE - MINIMUM SOIL COVERING (METRES) ACCORDING TO DS 430: - pipe below water table (terrain = water table) - soil compressed to 93% SP - y = 8 kN/m³ - pipe above water table - soil compressed to 93% SP 16 0,24 0,37 0,32 0,46 0,33 0,48 0,36 0,51 0,46 0,63 18 0,24 0,37 0,31 0,45 0,32 0,47...

Open the catalog to page 10
BLÜCHER® Below Ground Application brochure - 11

EASY INSTALLATION Manual pipe cutter Jointing of socket and spigot end Electric pipe cutter A detailed user guide is provided when buying or hiring an electric pipe cutter. Insertion depth Pipe Max. insertion depth Min. insertion depth dimension from end of socket from end of socket in mm to spigot end to spigot end 2 1 1. Cutting Use BLÜCHER® manual or electric pipe cutter to cut the pipes. The pipes can then be installed without subsequent finishing. NB! Fittings are not to be cut. 2. Check of lip seal Check that the lip sealing ring is correctly installed in the socket. 3. Cleaning If...

Open the catalog to page 11
BLÜCHER® Below Ground Application brochure - 12

BLÜCHER · Pugdalvej 1 · DK-7480 Vildbjerg · Tel.: +45 99 92 08 00 · export@blucher.com · www.blucher.com 22502 - CS Grafisk . 2000.08.08 Errors and omissions expected Copyright by BLÜCHER At BLÜCHER® more than 300 employees create an annual turnover of more than 50 million euro. Through know-how, dedicated service and common sense we develop, produce and market high quality stainless steel drainage solutions for customers within the housing, commercial, industrial and marine sectors all over the world. Find your local BLÜCHER® specialist at www.blucher.com