video corpo

DRAINAGE SYSTEMS FOR BELOW GROUND
16Pages

{{requestButtons}}

Catalog excerpts

DRAINAGE SYSTEMS FOR BELOW GROUND - 1

DRAINAGE SYSTEMS FOR BELOW GROUND STAINLESS STEEL DRAINAGE S YSTEMS

Open the catalog to page 1
DRAINAGE SYSTEMS FOR BELOW GROUND - 3

BELOW GROUND BLÜCHER® EuroPipe is the ideal drainage system for belowground use. The stainless steel systems offers the specifier and installer a metallic push-fit, lightweight and cost effective drainage system for foul and storm water drainage. Same pipe system below and above ground The piping system comes in stainless steel grades AISI 316L and AISI 304. BLÜCHER recommends the use of 316L because the risk of corrosion, caused by an aggressive environment, is significantly reduced or eliminated entirely by choosing the molybdenum stainless steel type AISI 316L. For CIP (cleaning in...

Open the catalog to page 3
DRAINAGE SYSTEMS FOR BELOW GROUND - 5

No blockages - easy rodding/cleaning Using BLÜCHER® drains with removable water traps enables the use of each drain as a rodding point, thus avoiding unhygienic cleaning wells with access covers in hygienic areas inside the building. If the piping layout is made with soft bends and 45° branches, the pipework system can be cleaned either by jet cleaning or mechanical cleaning by just removing the built-in water trap. Due to the hard stainless steel pipework material without coatings the piping offers the best resistance against mechanical cleaning. Piping layout with soft bends to allow easy...

Open the catalog to page 5
DRAINAGE SYSTEMS FOR BELOW GROUND - 7

PRODUCTS PIPES AND FITTINGS BLUCHER® EuroPipe includes a complete product range of pipes, bends, branches, access fittings and rodding eyes in standard dimensions 0110, 125, 160, 200, 250, 315 mm and standard lengths ranging from 0,15 m up to 6 m. BLUCHER recommends the use of minimum 0110 mm for belowground installations. Also local regulations may require the use of minimum 0110 mm. Customised items Customised items are available on request. Tools Our electric or manual BLUCHER® pipe cutter is used to cut pipes to lengths and bevel pipe ends for jointing. SELECTED PIPES Description...

Open the catalog to page 7
DRAINAGE SYSTEMS FOR BELOW GROUND - 8

SELECTED FITTINGS Description Dim. Item No. Long bend 90° Long bend 90° Long bend 90° Complete BLUCHER® EuroPipe product range including reducers, couplers and "P" traps can be seen at www.blucher.com and in our product catalogue.

Open the catalog to page 8
DRAINAGE SYSTEMS FOR BELOW GROUND - 9

RODDING EYES AND GASTIGHT DRAINS The BLUCHER® range for below-ground applications includes a complete range of rodding eyes and gastight drains. More drains are available in our standard product catalogue or at www.blucher.com. Customised items Customised items are available on request. RODDING EYES AND GASTIGHT DRAINS Description Outlet Item No. Handling w/nipple screw/vacuum handle w/nipple screw/vacuum handle w/nipple screw/vacuum handle w/nipple screw/vacuum handle Rodding eyes with 10 mm grate Rodding eye 150 0110 144.155.110.10 S screw/key Rodding eye 150 0110 sc...

Open the catalog to page 9
DRAINAGE SYSTEMS FOR BELOW GROUND - 10

ACCESS COVERS BLUCHER® access covers are produced from 2 mm stainless steel providing a high level of stability and durability. The access covers are designed with "eyes" and a taper fit for easy lifting and access. You can lift the covers manually or choose to use lifting equipment. A sealing ring below the lid prevents smell from spreading and ensures a water-tight solution. The access covers fulfill the standard EN 124. The cover can be mounted/fitted to the frame, and concrete anchors are premounted for safe construction. Use of concrete C35/C45 guarantees the load class mentioned...

Open the catalog to page 10
DRAINAGE SYSTEMS FOR BELOW GROUND - 11

ACCESS FITTINGS BLUCHER® access fittings are the traditional way of providing access to below-ground drainage under the building footprint or external to the building. Open half-section access liners can be provided if preferred. Customised items Customised items, including hatch boxes, are available on request.

Open the catalog to page 11
DRAINAGE SYSTEMS FOR BELOW GROUND - 12

INSTALLATION Filling around the pipe Filling around the pipe can only start when the position of the pipe has been checked and approved. Compression Avoid tipping the filling directly onto the pipe. If a machine is used for compression, the equipment’s own weight and impact force must be adapted to conditions. The filling should be compressed to at least 93%. Filling the excavation Soil from the excavation can be used for filling, but larger stones and blocks are not to be used. Compression of the filling material outside reinforced areas is not necessary if the settling will not cause problems...

Open the catalog to page 12
DRAINAGE SYSTEMS FOR BELOW GROUND - 13

VALUES FOR MINIMUM AND MAXIMUM SOIL COVERING Conditions: - Pipe above ground water level. - Soil compressed to 93% (standard proctor) Minimum soil covering Maximum soil covering Please note, that 0250mm and 0315mm calculations are based on "slacker pipes" according to DS 430 Where min. values are given in the tables for soil covering, also the frost-free depth must be taken into account.

Open the catalog to page 13
DRAINAGE SYSTEMS FOR BELOW GROUND - 14

Pipes cast in raft foundations Piled ground expected to settle 38 mm water gauge air test Pipe brackets and tie rods to hang from slab Compact surround or use self-compacting backfill (comp. fraction <0,2) Backfill with free-flowing self-compacting material

Open the catalog to page 14
DRAINAGE SYSTEMS FOR BELOW GROUND - 15

1. Cutting Use BLUCHER® manual or electric pipe cutter to cut the pipes. The pipes can then be installed without subsequent finishing. NB! Fittings are not to be cut. 2. Check of lip seal Check that the lip sealing ring is correctly installed in the socket. 3. Cleaning If necessary, clean lip seal and socket before jointing. Apply lubricant to the spigot. 4. Jointing Joint the pipes with a turning movement. A detailed user guide is provided when buying or hiring an electric pipe cutter.

Open the catalog to page 15
DRAINAGE SYSTEMS FOR BELOW GROUND - 16

BLUCHER A WATTS Brand At BLUCHER® more than 350 employees create an annual turnover of more than 65 million euro. Through know-how, dedicated service and common sense we develop, produce and market high quality stainless steel drainage solutions for customers within the housing, commercial, industrial and marine sectors all over the world. Find your local BLUCHER® specialist at www.blucher.com BLUCHER* Channel BLUCHER* Drain BLUCHER Metal A/S Pugdalvej 1 7480 Vildbjerg Tel.: +45 99 92 08 00 Email: export@blucher.com www.blucher.com

Open the catalog to page 16

All Blucher france catalogs and technical brochures

  1. Separators

    4 Pages

  2. HygienicPro

    32 Pages