video corpo

RetroFAST

RetroFAST

RetroFAST

Product catalog summary
Introduction
Conventional septic systems often face issues with soil absorption components becoming clogged over time, leading to problems such as sluggish flushing and plumbing backups. RetroFAST® offers a solution to enhance these systems, preventing costly replacements.
RetroFAST® System Overview
RetroFAST® is designed to upgrade conventional septic systems by reducing high-strength waste concentrations and preventing clogging layers. It is suitable for both new constructions and existing systems, offering minimal site disruption and a cost-effective, long-lasting solution.
Specifications
Each RetroFAST unit includes an insert, lid, blower assembly, and housing. The blower can be mounted up to 100 feet away, and the system requires standard household power (120v, 60Hz), with other options available. The system is made from corrosion-resistant materials and can be housed in various tank types.
Functionality
RetroFAST® works by applying highly treated, oxygenated wastewater to failing soil absorption systems, promoting aerobic bacteria growth that digests clogging layers. This process helps repair biologically failed systems.
Site Suitability
Most new or failing conventional systems can benefit from RetroFAST®, but site-specific evaluations are recommended. Consultation with Bio-Microbics or local dealers is advised to determine suitability.
Certifications and Approvals
RetroFAST® systems are certified by various international and national organizations, including the UK Department of Trade, European Union, US Coast Guard, and US Environmental Protection Agency, among others.
Product Variants
RetroFAST offers different models with varying capacities: 0.150 (150 GPD), 0.250 (250 GPD), and 0.375 (375 GPD), each designed for specific household sizes and treatment needs.
Conclusion
RetroFAST® provides a proven, safe, and reliable enhancement for septic systems, developed by Smith & Loveless, Inc., a leader in wastewater treatment technology.
See more

Catalog excerpts

RetroFAST-1

Septic System Enhancement Conventional septic systems utilize a septic tank to hold non-soluble materials and a soil absorption component (leach fi elds, for example) to provide the majority of treatment and disperse the wastewater. Over time, the soil absorption component can build up a clogging layer which can eventually prevent the wastewater from moving away from the system and through the soil. Sluggish fl ushing, soggy lawns, plumbing system backups or even surfacing wastewater can result. These unpleasant symptoms may force property owners to completely replace their soil absorption system. This drastic form of repair can be very costly and damaging to the existing property. There simply hasn’t been much choice...until now. Dependable, Affordable, and FAST® RetroFAST® wastewater treatment systems are used as an enhancement for conventional septic systems and provide a simple upgrade to renovate biologically failed septic systems. RetroFAST® also reduces the concentration of high strength waste, making it a good fi t for many troubled systems. When used with new home construction, the RetroFAST® delivers high levels of treatment to help assure the clogging layer never forms in the fi rst place. Minimal Site Disruption RetroFAST® is designed to be adapted and inserted into anexisting tank resulting in minimal site disruption. Minor modifi cation to the existing soil absorption system may be advisable. Low Cost, Long Lasting Solution Modernizing the wastewater treatment system with RetroFAST® increases value and usefulness of the property. Simple, Dependable Retrofi t Small communities now have a practical, proven alternative to cost prohibitive centralized sewer systems. Septic systems can receive signifi cant upgrades in their performance (including Nitrogen reduction) with the appropriate use of RetroFAST®. Better Water. Better World.

 Open the catalog to page 1
RetroFAST-2

Specifications Each RetroFAST unit comes equipped with the RetroFAST insert, insert lid, a blower assembly, blower housing and other needed hardware. The regenerative-type blower shall be mounted remote from the RetroFAST unit up to 100 feet (30.5 m) maximum. A two-piece, insulated housing is provided with tamper-proof screws. Power required: Normal household current (120v, 60Hz). Other options (220v and international requirements) are available. Made with 100% corrosionresistant material. FAST systems can be housed in concrete, fi berglass, steel or plastic tanks. Always check local regulations...

 Open the catalog to page 2

All BioMicrobics catalogs and technical brochures

  1. RollsAIR

    5  Pages

  2. Recover

    6  Pages

  3. SANITEE

    6  Pages

  4. d-Rain Joint

    6  Pages

  5. MarineFast

    6  Pages

  6. NitriFAST®

    6  Pages

  7. BioSTORM

    6  Pages

  8. StormTEE®

    2  Pages

  9. BioSTEP®

    2  Pages

  10. FOG HOG

    2  Pages

  11. LIXOR

    2  Pages

  12. Bio Barrier

    2  Pages

  13. MicroFAST

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.