The document outlines the specifications for the PIERAMUR® wall cladding system, which serves as a sound protection barrier and is suitable for low to medium height retention. Each element weighs 14 kg, with 38 elements required per square meter. The maximum height of the structure is 2.10 meters. The color of the elements varies by region. The system is designed for applications such as protection of dikes, ditches, and riverbanks.

Procedures
The implementation process involves excavating a 600mm wide trench to firm ground, laying a 100mm thick concrete base, and placing a 400mm wide layer of mesh reinforcement. The first course of blocks is laid and checked for level and plumb, followed by subsequent courses laid in stretcher bond. Backfilling is done with low fines material, compacted in layers of 100 to 200mm. A perforated land drain is introduced at the heel of the wall.

Standards and Recommendations
The land for the structure must be verified by an Approved Geotechnical Engineer. The responsibility for the quality of foundation soil, slope faces, backfill, and installation lies with the Employer or Contractor, not BETOCONCEPT®. The document provides guidelines for allowable heights based on the angle of internal friction of the ground (ϕ) and the angle of the slope upstream (β).

Key Parameters
- Maximum height: 2.10 m
- Weight of single element: 14 kg
- Number of elements per m²: 38
- Palette weight: 1568 kg
- Concrete foundation and reinforcement details provided
- Allowable heights vary based on soil quality and slope angle

Limitations
The document specifies that the trench should be free from groundwater and that the backfill material should be free from clay. The implementation process must adhere to local regulations regarding drainage systems.
See more

Catalog excerpts

pieramur-1

Low to medium height retention Wall cladding Weight of the single element: 14 kg Protection of dikes and ditches Sound protection barrier Palette weight: 1568 kg Colour: by region Element scored with a mallet and chisel System patented, trademark and design registered. Reproduction, even partial prohibited without permission. Information is given in good faith but is subject to change without prior notice.

 Open the catalog to page 1
pieramur-2

Number Wall of rows substructure 35° - good quality soil, mudstone, compact ground, gravel and sand 30° - land average with a maximum of 10% clay - angle of internal friction of ground ß = 0, horizontal overload taken into account: GARDEN H = 2,10 m After determining the location of the structure, excavate a perfectly horizontal, 600mm wide trench down to firm ground. This depth may vary according to location. The trench should be free from ground water. Lay a concrete base 100mm thick, placing on this a 400mm wide layer of 200 x 100mm grid size mesh reinforcement. Continue with a further 50mm...

 Open the catalog to page 2

All BETOCONCEPT catalogs and technical brochures

  1. BETOTITAN XL

    2  Pages

  2. Betophone®

    2  Pages

  3. Betojard ®

    2  Pages

  4. Betoflor ®

    2  Pages

  5. Betonap ®

    2  Pages

  6. Betoplus ®

    2  Pages

  7. Betotitan ®

    4  Pages

  8. Leromur ®

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.