Catalog excerpts
Technical drawings KEY: System: Return R/Flow F/Gas G Domestic water: Outlet O/Inlet I CDT: condensate drain trap 358 MYNUTE GREEN 12-15-25 R.S.I. E MYNUTE GREEN 25 C.S.I. E 102 MYNUTE GREEN 35 R.S.I. E MYNUTE GREEN 30-38 C.S.I. E 111.25 C Combi model (CH + DHW); R Heating Only model; S Room-sealed; I Ionisation flame control. CH nominal heat input CH nominal heat output (80°-60° C) CH nominal heat output (50°-30° C) CH minimum heat input CH minimum heat output (80°-60° C) CH minimum heat output (50°-30° C) Nominal Range Rated heat output (Qn) Minimum Range Rated heat output (Qm) DHW nominal input DHW maximum output* DHW minimum input DHW minimum output* Efficiency class according European Directive EEC 92/42 Efficiency at max - min nominal output (80°-60° C) Efficiency at partial load 30% (47°C return) Efficiency at max - min nominal output (50°-30° C) Efficiency at partial load 30% (30°C return) NOx class Max power consumption Power supply Electrical protection CENTRAL HEATING Maximum pressure - temperature Minimum pressure for standard operation Adjustable CH water temperature range CH expansion vessel pre-charge/Capacity DHW Maximum - minimum pressure DHW production ΔT=25°C/30°C/35°C Hot water minimum flow rate Adjustable hot water temperature range CONNECTIONS CH flow - return/Gas DHW inlet - outlet FLUE PIPES AND AIR INTAKE Max length (including 90° bend) for concentric 60-100mm Max length (including 90° bend) for concentric 80-125mm Max length for twin 80+80mm DIMENSIONS, WEIGTH, GAS Boiler dimensions (HxWxD) Net weight Certified gas types TWIN OUTLET CONCENTRIC OUTLET Technical data MYNUTE GREEN 25 C.S.I. E * average among the different functioning conditions in DHW ** LPG version available with separate kit (available as option) Beretta International Markets Trading address: Via Risorgimento 23/A - 23900 LECCO - ITALY Tel. +39-0341-277111 - fax +39-0341-277263 info@berettaboilers.com www.berettaboilers.com For all flueing configurations please refer to the current local and national rules. Mynute Green View from above Residential heating Condensing Wall-Hung Boilers In order to improve its product, Beretta reserves the right to modify the characteristics and information shown in this manual at any time and without advance warning. This brochure, therefore, cannot be considered as contractually binding on third parties. Mynute Green
Open the catalog to page 1Mynute Green MYNUTE GREEN is a condensing boiler ideal for installation in low temperature systems. Efficiency ★★★★ accoding to European Directive EEC 92/42. The RANGE RATED certification allows to adapt the power of the boiler to the real thermal requests of the installation. Stylish and easy-to-use control panel, equipped with a white backlight digital display. Low NOx emissions: Class 5 (the best according to the European Directive UNI EN 483), helping to safeguard the environment. Condensing heat-exchanger in extruded aluminium (Patent Pending) providing excellent thermal transfer....
Open the catalog to page 2Mynute Green MYNUTE GREEN is a condensing boiler ideal for installation in low temperature systems. Efficiency ★★★★ accoding to European Directive EEC 92/42. The RANGE RATED certification allows to adapt the power of the boiler to the real thermal requests of the installation. Stylish and easy-to-use control panel, equipped with a white backlight digital display. Low NOx emissions: Class 5 (the best according to the European Directive UNI EN 483), helping to safeguard the environment. Condensing heat-exchanger in extruded aluminium (Patent Pending) providing excellent thermal transfer....
Open the catalog to page 3Mynute Green MYNUTE GREEN is a condensing boiler ideal for installation in low temperature systems. Efficiency ★★★★ accoding to European Directive EEC 92/42. The RANGE RATED certification allows to adapt the power of the boiler to the real thermal requests of the installation. Stylish and easy-to-use control panel, equipped with a white backlight digital display. Low NOx emissions: Class 5 (the best according to the European Directive UNI EN 483), helping to safeguard the environment. Condensing heat-exchanger in extruded aluminium (Patent Pending) providing excellent thermal transfer....
Open the catalog to page 4Technical drawings KEY: System: Return R/Flow F/Gas G Domestic water: Outlet O/Inlet I CDT: condensate drain trap 358 MYNUTE GREEN 12-15-25 R.S.I. E MYNUTE GREEN 25 C.S.I. E 102 MYNUTE GREEN 35 R.S.I. E MYNUTE GREEN 30-38 C.S.I. E 111.25 C Combi model (CH + DHW); R Heating Only model; S Room-sealed; I Ionisation flame control. CH nominal heat input CH nominal heat output (80°-60° C) CH nominal heat output (50°-30° C) CH minimum heat input CH minimum heat output (80°-60° C) CH minimum heat output (50°-30° C) Nominal Range Rated heat output (Qn) Minimum Range Rated heat output (Qm) DHW...
Open the catalog to page 5Residential heating Condensing Wall-Hung Boilers Technical data C Combi model (CH + DHW); (R Heating Only model; |S Room-sealed; 4 Ionisation flame control. CENTRAL HEATING Maximum pressure - temperature Maximum - minimum pressure FLUE PIPES AND AIR INTAKE Max length (including 90° bend) for concentric 60-100mm Boiler dimensions (HxWxD) average among the different functioning conditions in DHW LPG version available with separate kit (available as option) Beretta International Markets Trading address: Via Risorgimento 23/A - 23900 LECCO - ITALY Tel. +39-0341-277111 - fax...
Open the catalog to page 6All Beretta catalogs and technical brochures
-
Product Catalogue
328 Pages
-
Tower Green HES 35/200
2 Pages
-
MYNUTE BOILER GREEN
6 Pages
-
EXCLUSIVE BOILER GREEN HE
8 Pages
-
CIAO GREEN
6 Pages
-
BERETTA_COMPANY_PROFILE_2014
30 Pages
-
Condensing Wall-Hung Boilers
6 Pages