Flue solutions 2021
4Pages

{{requestButtons}}

Catalog excerpts

Flue solutions 2021 - 1

Flue solutions Multifit flue kits come with positive screw fixings for all connections and are available in a choice of lengths to reduce the need for onsite cutting. We offer a choice of colour for the terminals to match existing rainwater systems. Flue type Maximum permissible equivalent flue lengths for Baxi heat only boilers are: Horizontal concentric Vertical concentric Horizontal concentric Vertical concentric Maximum permissible equivalent flue lengths for Baxi combi and system boilers are: Flue type Where inline bends are required in a flue system, the overall length must be reduced by the following amounts: Reduction for each bend Concentric pipes Terminal position with minimum distance J,K Likely flue positions requiring a flue terminal guard 1. addition, the terminal should be no nearer than 150mm to an In opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame. 2. Only ONE 25mm clearance is allowed per installation. If one of the dimensions D, E, F, G or H is 25mm then the remainder MUST be as B.S.5440-1. Terminal assembly IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors Top view rear flue Property boundary line NOTE: The distance from a fanned draught appliance terminal installed parallel to a boundary may not be less than 300mm in accordance with the diagram. Opening window or door 150mm min. Directly below an opening, air brick, opening windows etc 300 Above an opening, air brick, opening window etc 300 Horizontally to an opening, air brick, opening window etc 300 Below gutters, soil pipes or drain pipes 25 Below eaves 25 Below balconies or car port roof 25 From a vertical drain pipe or soil pipe 25 From an internal or external corner 25 Above ground, roof or balcony level 300 From a surface or boundary line facing a terminal 600 From a terminal facing a terminal (Horizontal flue) 1200 From a terminal facing a terminal (Vertical flue) 600 From an opening in a carport (e.g. door, window) into the dwelling1200 Vertically from a terminal on the same wall 1500 Horizontally from a terminal on the same wall 300 From adjacent wall to flue (vertical only) 300 From an adjacent opening window (vertical only) 300 Adjacent to windows or openings on pitched and flat roofs 600 Below windows or openings on pitched roofs 2000

Open the catalog to page 1
Flue solutions 2021 - 2

Flue solutions Concentric flues Ø 60/100mm Multifit Flue Group A Horizontal telescopic flue inc. low profile elbow and fixing screws Horizontal telescopic flue inc. low profile elbow and fixing screws Horizontal telescopic flue inc. low profile elbow and fixing screws Standard horizontal flue inc. low profile elbow and fixing screws* 135° flue bend inc. fixing screws White pipe / white terminal White pipe / black terminal White pipe / brown terminal White pipe / black terminal SALES CODE SALES CODE SALES CODE SALES CODE 135° flue bend inc. fixing screws (pair) 93° flue bend inc. fixing...

Open the catalog to page 2
Flue solutions 2021 - 3

Flue solutions Plume displacement terminal kit for telescopic flue inc. 1m extension and brackets** Plume displacement terminal kit for telescopic flue inc. 1m extension and brackets*** Plume displacement kits Ø 60/100mm Multifit Flue Group A Plume displacement kit extension and brackets Standard horizontal flue including plume displacement kit Includes flue kit and plume displacement 60mm **Only compatible with 720599401 Plume displacement kit extension and brackets SALES CODE SALES CODE SALES CODE SALES CODE ***Only compatible with 720598701 Standard horizontal flue including plume...

Open the catalog to page 3
Flue solutions 2021 - 4

Flue solutions Multifit Flue Group G Horizontal flue inc. boiler and terminal adaptors Flue bend Flue bend (pair) Pipe support bracket SALES CODE SALES CODE SALES CODE SALES CODE Vertical flue terminal Roof cover plate Flue vertical adaptor Pitched roof flashing 125mm flue pipes DIAMETER Flat roof flashing White SPECIFICATION SALES CODE SALES CODE SALES CODE SALES CODE SALES CODE Flue solutions Baxi Multifit IFOS (In Flue Outdoor Sensor) Multifit IFOS (Combi) Multifit IFOS Extension Multifit IFOS System Multifit Ridge Tile IFOS Horizontal and vertical flue terminal sensor clips Extends...

Open the catalog to page 4

All BDR Thermea catalogs and technical brochures

  1. Baxi Assure

    28 Pages

  2. Assure Heat

    3 Pages

  3. Range Guide

    32 Pages

  4. Geoflo

    4 Pages

  5. baxi

    32 Pages

  6. Solo HE A

    8 Pages

  7. Solarflo™

    20 Pages

Archived catalogs

  1. Ambiflo™

    16 Pages

  2. baxi biomass

    28 Pages