Ambiflo™
16Pages

{{requestButtons}}

Catalog excerpts

Ambiflo™ - 1

BAXI Ambiflo Airsourceheatpumpsystems

Open the catalog to page 1
Ambiflo™ - 2

to Baxi Innovators in heating technology For more than 150 years, Baxi has been at the forefront of heating technology - a renowned and respected brand, which has consistently led the way with new and pioneering heating solutions. Today, our dedication to innovation is greater than ever as we lookto new ways to heat homes and businesses; ways that will utilise renewable sources of energy and can play their part in protecting the planet for future generations. Interest in low carbon technology has grown significantly overthe last few years and we recognise the increasingly important role...

Open the catalog to page 2
Ambiflo™ - 3

What is an air source heat pump? Creating heat from thin air Baxi Ambiflo is an airto water heat pump, providing central heating for domestic properties. Outside air contains a reliable level of heat that can be captured by this one piece air source heat pump for use in the home. Baxi Ambifloٙ air source heat pumps take the latent heat from outside air and use this energy to provide heating within the home. Air source heat pumps can offer substantial carbon savings compared to other heating sources such as electric storage heaters and oil boilers. Under typical conditions, air source heat...

Open the catalog to page 3
Ambiflo™ - 4

BAXI How do air source heat pumps work? Air source heat pumps work on the same basic principles as a refrigerator (but in reverse), taking heat from the air and converting it into usable heat for the home A heat pump typically consists of four main components; evaporator, compressor, condenser and expansion valve. A refrigerant is circulated around these components. low it works 1. Outside air is drawn over the evaporator. The refrigerant absorbs heat from the air and changes from a liquid to a vapour. 2. The refrigerant then passes through a compressor, increasing the pressure and...

Open the catalog to page 4
Ambiflo™ - 5

Ambiflo TheBaxiAmbifloٙ is externally sited and idealfor central heating. This one piece heat pump has a closed and pre-charged refrigeration circuit - so there's no need for refrigerant handling during installation. Designed for heating system temperatures between 25°C and 45°C, the Baxi Ambiflo can fulfil allthe central heating needs of a domestic property down to low outside temperatures. Suitable heat emitters include low temperature panel radiators, skirting radiators, fan convector radiators, underfloor heating or oversized high temperature panel radiators.* The Baxi Ambifloٙ air...

Open the catalog to page 5
Ambiflo™ - 6

IAX1 Ambiflo components r Baxi Ambifloٙ and Buffer Pack The Ambiflo Buffer Packcontains: Heat pump Flexible connection hoses Programmable room thermostat Outdoor sensor Megaflo buffer vessel ٕ Auxiliary electric heater Flow regulator Օ Heater connection kit Supplementary flow/return sensors The use of a buffer vessel is recommended in low to medium volume systems* The additional volume reduces cycling which enhances efficiency. It also provides a defrost heat source and allows customers to take advantage of off peak electric tariffs. * For radiators, system volumes lowerthan 70 litres with...

Open the catalog to page 6
Ambiflo™ - 7

[fil Ambiflo applicatioi The Baxi Ambifloٙ is suitable for heating Systems that use low temprature panel radiators, skirting radiators, fan connector radiators, underfloor heating or oversized high temperature panel radiators. Typical applications are shown below: Radiator heating system Outdoor Sensor Programmable room thermostat Underfloor heating system Outdoor Sensor Programmable room thermostat 10 6 9 8 13 1. 100 litre buffer vessel 2. Auxiliary electric heater' 3. Primary pump located in unit2 4. Flow regulator' 5. System pump2 6. Waterfilter' 7. Dirt remover 1 Supplied as standard...

Open the catalog to page 7
Ambiflo™ - 8

IAX1 Ambiflo features System ٕ Heating only unit, easily sited externally without takjng up useful indoor space Self-contained, one piece heat pump with a closed and pre-charged refrigeration circuit -no need for external refrigerant pipe workor refrigerant handling during installation Օ Output choice of 7.5kW, 9.0kW and 10.5kW to match the heat load requirements of the property1 Compact and low weight for easy installation in various locations including load bearing flat roofs Օ Baxi Ambiflo can be fitted on an optional wall mounting bracket for siting flexibility1 (available as an...

Open the catalog to page 8
Ambiflo™ - 9

mi Electric heater Performance Unit Output kW 2x2.5 Dimensions and weight Height mm 425 Width mm 250 Depth mm 200 Weight kg 9 Connections Power supply V(Hz) 230 (50) Cable min core diameters' mm2 6 Room controls VDC 5 Cable min core diameters mm2 0.5 CH flow2 inch 1 CH return2 inch 1 Operating conditions Max operating current A 22 1 Reference should also be made to current regulations. 2 Heater connection kit, flexible hoses and 15mm or 22mm compression fittings adapters are included in the system pack as standard. Megaflo buffervessel Performance Unit Capacity l 100 Heat loss kW/24hr 1.14...

Open the catalog to page 9
Ambiflo™ - 10

IAX1 Ambiflo s٩lection A guide to selecting your Ambiflo packis provided below: IMPORTANT: Before ordering, a design heat load calculation must be carried out based on information from drawings or collected during a site assessment, contact Baxi forfurther information. Selection of the appropriate Ambifloٙ system must be based on the calculated heat load value. Selecting in line withthese tables willensure optimum use of the Ambiflo down to sub zero temperatures. Below 1 oC outside temperature a small integral supplementary heater is enabled. Alternatively, a separate supplementary heater...

Open the catalog to page 10
Ambiflo™ - 11

Ambiflo ordering IMPORTANT: Before ordering, a design heat load calculation must be carried out based on information from drawings or collected during a site assessment, contact Baxi for further information. S٩lection of the appropriate Ambiflo system must be based on the calculated heat load value. Sizing of the radiators forthe lower average system temperature is also important. Excessive oversizing can lead to overheating problems. System packs Baxi Ambifloٙ and buffer pack Baxi Ambiflo and heater pack Ambifloٙ 75 & buffer pack Ambiflo 90 & buffer pack Ambifloٙ105& buffer pack Ambiflo 75...

Open the catalog to page 11