BAUTECH TL SYSTEM NOVEMBER 2012 1/2 BAUTECH TL SYSTEM SYSTEM DESCRIPTION  A thin‐layer flooring system for industrial and public facilities subject  to  pressure  corresponding  to  light  and  medium conditions  of  wheel  transport and periodical pedestrian traffic.           Resistant to impacts, pressure and shocks typically occurring  during  the loading of light and medium cargo.     AREAS OF APPLICATION   A flooring system to be used on stabilized concrete foundations and  cement screeds, meeting standard smoothness and capacity‐carrying  parameters, e.g. :   technical rooms   utility rooms   storage facilities   parking areas    USABILITY   At the temperature of 20˚C and relative air humidity of 60‐70%:   ‐ pedestrian traffic – after 24 hours   ‐ mechanical loads – after 72 hours   ‐ complete resistance – after 7 days.  CAUTION  System is not resistant to metal and polyamide wheel loads.     LEGAL NOTES  All  information  contained  herein  is  based  on  the  current  state  of  knowledge resulting from performed trials and laboratory tests. As it  has no control over the actual manner and conditions of application  of  materials  included  in  the  system,  Bautech  Sp.  z  o.o.  informs  that  the data contained herein as well as any oral advice not confirmed in  writing may not constitute a basis for unconditional legal liability of  the producer.   All previous technical sheets become void with the publication of this  one.   MISCELLANEOUS INFORMATION  Other  information  regarding  the  conditions  of  application,  use,  cleaning and maintenance of polymer floors by Bautech Floor System  is  included  in  Technical  Instructions  and  Technical  Sheets  of  individual products.     Concrete foundation must be stable and  of proper carrying capacity  for  the  target  static  and  dynamic  loads  –  concrete    of  class  no  less  than  C20/25  of  minimal  stripping  strength  1.5  N/mm2.  The  acceptable humidity of the foundation must not exceed 4% in terms  of weight.  The  foundation  must  have  a  hermetic  horizontal  insulation  protecting it from moisture sucked up through capillary tubes.     Foundations  which  are  to  be  protected  with  epoxy  layers  must  be  clean  and  absorbent.    Cement  wash,    dirt  of  all  kinds  and  old  protection  layers  should  be  removed  mechanically  by  grinding,  shot  blasting or milling.     

 Open the catalog to page 1

BAUTECH PARKING SYSTEM NOVEMBER 2012 2/2   DETAILED DESCRIPTION OF TECHNOLOGY    Grounding layer  Material: BAUPOX 100 STR.   Spread  properly  mixed  material  on  concrete  foundation  in  one  or  two  layers,  using  a  rubber  squeegee  and  then  a  roller,  until  full  saturation is achieved.    Consumption: 0,25 – 0,50 kg/m2.    1st main layer    Material: BAUPOX 200   Spread the resin evenly on the foundation using a roller for resins.   After  polymerization,  delicately  regrind  the  surface  with  a  grinder  with abrasive paper and then remove dust from the whole of it.   ...

 Open the catalog to page 2

All BAUTECH catalogs and technical brochures

  1. AGRO-FLOORS

    4 Pages

  2. BAUTECH FUTURA

    17 Pages

  3. BAUTOP® ENDURO

    2 Pages

  4. catalogue

    11 Pages

  5. UNIFLOOR®

    2 Pages

  6. BAUFLEX® 35

    2 Pages

  7. TERRAFILL®

    1 Pages

  8. NANOSEAL®

    2 Pages