Catalog excerpts
ACL SKYLIGHTS FIXED FOR WELL-LIT ENVIRONMENTS ACL Skylights are also available in a fixed version, used when an environment needs light over a greater space. In areas needing ventilation it is possible to use the mixed ACL system (see pg.44), guaranteeing optimum light and air flow. WALL INSTALLATION
Open the catalog to page 1ACL SKYLIGHTS INSULATED THERMAL INSULATION IN A WORKING ENVIRONMENT To guarantee a constant temperature in the working environment (e.g. needed for the food sector) it is possible to insulate the skylight by installing shades of various thicknesses, positioned between the cover and the opening frame. Basso Lucernari can offer assistance in the planning phase to find and create the solution according to clients needs. SAFETY NET (ANTI-FALL) All skylights can be fitted with an anti-fall safety net, mosquito net, bird net and anti-break-in net. OPENABLE FRAME SECTION WITH SHADE
Open the catalog to page 2GALVANIZED STEEL BASES To guarantee suitable insulation, the bases are insulated with auto-extinguishing expanded polyurethane panels with a thickness of 3-4 cm. Assembly and positioning is fast and easy: each base comes provided with all metal anchoring devices and positioning instruction manual. GALVANIZED STEEL GALVANIZED STEEL GALVANIZED STEEL BASE NATURAL ALUMINIUM FLOOR COVERING FLOOR COVERING FLOOR COVERING PVC BASE The shape of the base is reamed to allow better diffusion of light. The metallic bases, in galvanized sheet or other chosen metal, can have vertical or reamed sides and...
Open the catalog to page 3BASE DIMENSIONS GALVANIZED STEEL AN APPROPRIATE BASE FOR EACH SKYLIGHT BASES (FOR SKYLIGHTS) Different bases are available for each type of skylight, varying in shape and material. The choice is aimed at the best installation and performance of the product. Basso Lucernari has a warehouse with a wide choice of bases: in steel, PVC and with square or rectangular base. BASES (FOR VENTILATION) The metallic base for natural ventilation consists of extruded aluminium modular slats of 15 cm, 30 cm, and 45 cm height. The particular shape of the slats allows suitable ventilation, preventing the...
Open the catalog to page 4OUR PROFILES BASSO LUCERNARI have planned a wide range of profiles in natural or anodized aluminium, with designed sections which vary depending on the type of skylight. PROFILE ANGULAR To avoid welding the frames BASSO LUCERNARI have patented graft pressure-cast corners with the aim of avoiding caulking which can result from infiltrated water. EXTERNAL DIMENSIONS PANE THICKNESS PANE THICKNESS EXTERNAL SUPPORT (meters) The table on the right shows the external dimensions of the skylight related to the thickness of the polycarbonate panes. COVERING MATERIALS PANE SECTIONS IN ALVEOLAR...
Open the catalog to page 5METHACRYLATE PMMA Compact methacrylate (PMMA) flat panes guaranteed synthesis original, as the material is of the highest quality, exempt from recovery monomers. The optical and physical-mechanic properties typical of pure polymer are guaranteed to be unchangeable; normally exposed to the outside for ten years with total protection from UV rays, with the following technical characteristics. Compact polycarbonate (PC) flat panes are guaranteed auto-extinguishing with certification of proof "Class 1A" of reaction to fire and synthesis original as the material is of the highest quality and is...
Open the catalog to page 6STAGES OF INSTALLATION The sequence of photos shows the ascending moments of installation of skylights on the roofing of industrial warehouses: from mounting the frame to the roof to the final application of silicon to the skylights. Photo 1: Lorry equipped with basket for safer and quicker access to the roofing. Photo 2: Lorry equipped with tow and crane, with an arm of 27mt for raising the material.
Open the catalog to page 7INSTALLATION A TEAM JOB FOR ACCURATE INSTALLATION Basso Lucernari places a lot of attention on the most delicate stage of delivery: installation. They have various assembly teams in the company, well-prepared people who are able to carry out each stage of installation according to active regulations. • INSTALLATION ON ROOF DECK • INSTALLATION ON ROOFING WITH A “Y” BEAM • INSTALLATION ON CURVED ROOFING • INSTALLATION ON SLOPED SURFACE • INSTALLATION ON THE R
Open the catalog to page 8INSTALLATION ON ROOF DECK The base has an inferior edge for attachment to the roof deck, with vertical sides for the possible insertion of insulation.
Open the catalog to page 9INSTALLATION ON ROOFING WITH A “Y” BEAM A valley gutter is fixed and applied with silicon at the contact point between the base and the roofing mantle (to the sides of the base). The space between the false ceiling and the base is closed with a moulded panel in the form of a beam. The fixing of the base to the beam is carried out using steel brackets. Side closing gable in polystyrol (standard), galvanised steel with white grey finishing, stainless steel, and aluminium.
Open the catalog to page 10INSTALLATION ON CURVED ROOFING A galvanized steel valley gutter is fixed and applied with silicon at the contact point between the base and the roofing mantel of the building. The longer sides have an edge for the support and fixing of the base to the purlins.
Open the catalog to page 11INSTALLATION ON SLOPED SURFACE The base is made in counter slope and has a channel for the collection of water carried in the roofing.
Open the catalog to page 12INSTALLATION ON THE ROOF TOP A galvanized steel valley gutter is fixed and applied with silicon at the contact point between the basement and the roofing mantel of the building along the whole perimeter. The longer sides have an edge for the support and fixing of the base to the purlins.
Open the catalog to page 13INSTALLATION ON SLOPED SURFACE The base is made in counter slope and has a channel for the collection of water carried to the gutter.
Open the catalog to page 14All BASSO FRANCO catalogs and technical brochures
-
EXS Smoke and heat vent
6 Pages
-
ACL SKYLIGHTS
18 Pages
-
ADR deluxe
1 Pages
-
SKYLIGHTS
48 Pages
-
ADR VENTILLATORS
20 Pages
-
DOMES
32 Pages