Catalog excerpts
Safe. Strong. Styrodur® □•BASF We create chemistry Technical Data Application Recommendations Dimensioning Aids IT
Open the catalog to page 1Application type according to DIN 4108-10 or Product properties according to DIN EN 13164 and DIN 4108-10 2800 C 3000 CS/SQ 4000 CS/SQ 5000 CS/SQ Hybrid general construction type approval (CTA)/ETA Cavity insulation Inverted roof 1 Insulation with ground contact 2) Not under composite stone pavement 3) With protective layer over sealing barrier dm = 200 kPa, dh = 300 kPa, ds = 500 kPa, dx = 700 kPa
Open the catalog to page 2Standard/ CTA*/ETA** 1 100 kPa = 10 N/cm2 = 100 kN/m2 = 10 to/m2 2) Declared value of the creep stress as per ETA 3) Rated value of the creep stress as per CTA * CTA = Construction Type Approval ** ETA = European Technical Assessment *** From 100 mm, smaller than 100 mm WD(V) 3
Open the catalog to page 3Application types Description Ceiling, roof 1 The abbreviations used refer to areas of application for thermal insulation. Graphical symbols are given below this table. 2) I ncluding application from below, in contact with the outside air. 3) Area of application/abbreviation WAP does not apply to insulation boards in external thermal insulation composite systems (ETICS). ETICS are not a standardised application. 4) The specifications according to DIN 4108-2 are applicable.
Open the catalog to page 41 When using sheet asphalt screeds, temperature-resistant insulation materials (ds or dx) are required for the insulation layer directly below the screed.
Open the catalog to page 53. Thermal Conductivity of Styrodur® 3.1 Applications According to DIN 4108 Thermal conductivity W/(m·K) and thermal resistance (m²·K)/W of Styrodur ® 2800 C Thermal conductivity Thermal resistance Rated value as per DIN 4108 Thickness λD = declared thermal conductivity as per DIN EN 13164 RD = declared thermal resistance as per DIN EN 13164 λB = rated value of thermal conductivity as per DIBt approval in line with DIN 4108 CS/SQ = thicknesses ≥160 mm are referred to as SQ 3.2 Technically Approved Applications Overview of general construction type approvals (CTA): Styrodur® 3000 CS/SQ, 4000...
Open the catalog to page 63.3 Technically Approved Applications Rated values of thermal conductivity in W/(m·K) as per DIBt construction type approval Approved Styrodur® types: 3000 CS/SQ, 4000 CS, 5000 CS Thermal insulation under load-bearing foundation slabs Thickness in mm Multi-layer with soil moisture Soil Pressing moisture water Wall area Inverted roof constructions Under basement floors With gravel layer and separation layer Singlelayer * According to DIN 4108, the rated lambda value λB may be used for these standar
Open the catalog to page 7Dynamic stiffness of Styrodur® 3000 CS/SQ, 4000 CS/SQ, and 5000 CS/SQ 5. Dimensioning Aids for Styrodur®5.1 Load-bearing Floor Slabs Dimensioning aids for Styrodur® applications under load-bearing floor slabs
Open the catalog to page 85.3 Vehicle Traffic Vehicle traffic Available compressive stress with traffic load in kPa Non-reinforced layer structure2) Layer thickness above insulation board in mm Weight Type Wheel load Reinforced concrete Static height in mm Contact surface Heavy-goods vehicle (HGV), truck, and car according to DIN 1072; forklift according to DIN 1055. I mportant note: For reasons of long-term positional stability, the deformation under compressive stress due to traffic loads may not exceed 0.7 mm *); therefore, in case of composite stone pavements with compressive stresses, for which the use of...
Open the catalog to page 9Styrodur® = reg. trademark of BASF SE Styrodur® – A Strong Product Line With the Styrodur® product line, BASF offers the ideal insulation solution for almost every application. Styrodur ® 2800 C The thermal insulation board with an embossed honeycomb pattern on both sides and smooth edges for applications in combination with concrete, plaster, and other top coats. Styrodur ® 3000 CS/SQ The innovative multipurpose thermal insulation board with smooth surfaces and shiplap for almost all applications in structural and civil engineering and with uniform thermal conductivity across all board...