STYRODUR ®

STYRODUR ®
1 / 10 PagesView full catalog

STYRODUR ®

Product catalog summary
Application Recommendations for Styrodur®
Styrodur® is versatile and recommended for applications such as perimeter insulation, living area floors, industrial and refrigerated warehouse floors, cavity insulation, and interior insulation. It is suitable for various construction types, including inverted roofs, green roofs, and parking roofs, following DIN standards and construction type approvals.
Technical Data for Styrodur®
The technical specifications cover compressive strength, adhesive strength, modulus of elasticity, dimensional stability, deformation behavior, thermal expansion, fire behavior, water absorption, and application temperature limits, all defined by DIN EN standards to ensure reliability and performance.
Thermal Conductivity of Styrodur®
Thermal conductivity and resistance values are specified for different board thicknesses, meeting DIN 4108 standards. The product is approved for use under load-bearing foundation slabs and in perimeter insulation.
Mechanical Parameters
Details on dynamic stiffness and modulus of subgrade reaction are provided for different Styrodur® types, crucial for dimensioning aids in load-bearing floor slabs and permissible installation depths, ensuring structural integrity under various loads.
Dimensioning Aids for Styrodur®
Guidance is provided for applications under load-bearing floor slabs and in perimeter insulation, specifying permissible installation depths for different load scenarios, including earth pressure and groundwater conditions.
Adhesive Bonds for Styrodur®
Recommendations for adhesive types suitable for substrates like mineral, plaster base, metal, wood, and plastic ensure proper bonding and performance in various construction applications.
Conclusion
Styrodur® provides a reliable insulation solution for diverse construction applications, meeting industry standards and ensuring optimal performance in various environmental conditions.
Product Overview
The document highlights different types of Styrodur® boards used in structural and civil engineering, emphasizing their unique features and applications.
Styrodur® 4000/5000 CS/SQ
These boards are designed for maximum compressive strength, featuring smooth surfaces and shiplap edges, making them highly compression-proof.
Styrodur® 3000 BMB
This multipurpose board is made using renewable raw materials, maintaining the same technical properties as conventional Styrodur CS/SQ, contributing to resource conservation and CO2 emission reduction.
Styrodur® Hybrid
Characterized by longitudinal grooves on one side and a shiplap edge, this board is used for perimeter insulation in concrete pouring with waterproof concrete exterior basement walls.
See more

Catalog excerpts

STYRODUR ®-1

Safe. Strong. Styrodur® □•BASF We create chemistry Technical Data Application Recommendations Dimensioning Aids IT

 Open the catalog to page 1
STYRODUR ®-2

Application type according to DIN 4108-10 or Product properties according to DIN EN 13164 and DIN 4108-10 2800 C 3000 CS/SQ 4000 CS/SQ 5000 CS/SQ Hybrid general construction type approval (CTA)/ETA Cavity insulation Inverted roof 1 Insulation with ground contact 2) Not under composite stone pavement 3) With protective layer over sealing barrier dm = 200 kPa, dh = 300 kPa, ds = 500 kPa, dx = 700 kPa

 Open the catalog to page 2
STYRODUR ®-3

Standard/ CTA*/ETA** 1 100 kPa = 10 N/cm2 = 100 kN/m2 = 10 to/m2 2) Declared value of the creep stress as per ETA 3) Rated value of the creep stress as per CTA * CTA = Construction Type Approval ** ETA = European Technical Assessment *** From 100 mm, smaller than 100 mm WD(V) 3

 Open the catalog to page 3
STYRODUR ®-4

Application types Description Ceiling, roof 1 The abbreviations used refer to areas of application for thermal insulation. Graphical symbols are given below this table. 2) I ncluding application from below, in contact with the outside air. 3) Area of application/abbreviation WAP does not apply to insulation boards in external thermal insulation composite systems (ETICS). ETICS are not a standardised application. 4) The specifications according to DIN 4108-2 are applicable.

 Open the catalog to page 4
STYRODUR ®-5

1 When using sheet asphalt screeds, temperature-resistant insulation materials (ds or dx) are required for the insulation layer directly below the screed.

 Open the catalog to page 5
STYRODUR ®-6

3. Thermal Conductivity of Styrodur® 3.1 Applications According to DIN 4108 Thermal conductivity W/(m·K) and thermal resistance (m²·K)/W of Styrodur ® 2800 C Thermal conductivity Thermal resistance Rated value as per DIN 4108 Thickness λD = declared thermal conductivity as per DIN EN 13164 RD = declared thermal resistance as per DIN EN 13164 λB = rated value of thermal conductivity as per DIBt approval in line with DIN 4108 CS/SQ = thicknesses ≥160 mm are referred to as SQ 3.2 Technically Approved Applications Overview of general construction type approvals (CTA): Styrodur® 3000 CS/SQ, 4000 CS,...

 Open the catalog to page 6
STYRODUR ®-7

3.3 Technically Approved Applications Rated values of thermal conductivity in W/(m·K) as per DIBt construction type approval Approved Styrodur® types: 3000 CS/SQ, 4000 CS, 5000 CS Thermal insulation under load-bearing foundation slabs Thickness in mm Multi-layer with soil moisture Soil Pressing moisture water Wall area Inverted roof constructions Under basement floors With gravel layer and separation layer Singlelayer * According to DIN 4108, the rated lambda value λB may be used for these standar

 Open the catalog to page 7
STYRODUR ®-8

Dynamic stiffness of Styrodur® 3000 CS/SQ, 4000 CS/SQ, and 5000 CS/SQ 5. Dimensioning Aids for Styrodur®5.1 Load-bearing Floor Slabs Dimensioning aids for Styrodur® applications under load-bearing floor slabs

 Open the catalog to page 8
STYRODUR ®-9

5.3 Vehicle Traffic Vehicle traffic Available compressive stress with traffic load in kPa Non-reinforced layer structure2) Layer thickness above insulation board in mm Weight Type Wheel load Reinforced concrete Static height in mm Contact surface Heavy-goods vehicle (HGV), truck, and car according to DIN 1072; forklift according to DIN 1055. I mportant note: For reasons of long-term positional stability, the deformation under compressive stress due to traffic loads may not exceed 0.7 mm *); therefore, in case of composite stone pavements with compressive stresses, for which the use of Styrodur...

 Open the catalog to page 9
STYRODUR ®-10

Styrodur® = reg. trademark of BASF SE Styrodur® – A Strong Product Line With the Styrodur® product line, BASF offers the ideal insulation solution for almost every application. Styrodur ® 2800 C The thermal insulation board with an embossed honeycomb pattern on both sides and smooth edges for applications in combination with concrete, plaster, and other top coats. Styrodur ® 3000 CS/SQ The innovative multipurpose thermal insulation board with smooth surfaces and shiplap for almost all applications in structural and civil engineering and with uniform thermal conductivity across all board thicknesses....

 Open the catalog to page 10

All BASF Energy efficiency catalogs and technical brochures