Baumit StarTex - 1

Product Data Sheet Alkaline resistant, glass fibre textile mesh for use with external wall insulation systems. Tested according to ETAG 004. Provides reinforcement for Baumit contact mortars. Strengthens basecoats for Baumit External Wall Insulation systems, render carrier boards and general basecoat renders and plasters. SBR coated glass fibres (styrene butadiene rubber). Properties Optimised load failure and expansion. Technical data Mesh size: approx. Surface/weight ratio: Tensile strength: Tensile strength after ageing: Consumption: Yields: Health and safety Not subject to labelling requirements! Storage Store upright in dry conditions. Quality assurance In house monitoring through our own laboratories. Third party inspection is carried out through a certified body. Packaging 50 m2 roll, (width 1 m, length 50 m), 1 pallet = 33 rolls = 1650 m2 carrier boards and render substrates: Baumit contact mortar is applied to the substrate surface with a stainless steel notched trowel (10 mm notches). Continuous sheets of StarTex reinforcing mesh are placed onto the contact mortar, free of creases and with 100 mm overlapping edges. A further 1- 3mm of contact mortar is applied “wet on wet “over the embedded StarTex reinforcing mesh. The StarTex reinforcing mesh must be covered with at least 1 mm (0.5 - 3 mm max. at the overlapping edges) of contact mortar. Excessive trowelling is to be avoided. Trowel lines are to be removed after hardening. The overall basecoat thickness must be from 3 - 8 mm depending on the type of substrate and contact mortar. Diagonal reinforcement: Embed Baumit StarTex (min. 200 x 300 mm sheets) strips in a tight coat of contact mortar applied diagonally across the corners of windows and door openings prior to reinforcing the main areas. Edges and corner reinforcement: Corners and edges are generally formed using purpose made Baumit corner beads with mesh wings fully embedded in contact mortar. If these profiles are not used, then the StarTex reinforcing mesh and contact mortar is continued around the edge or corner by at least 200 mm, and maintaining overlaps to adjoining sheets by at least 100 mm. Internal corners: Internal corner reinforcement follows the same procedure as the external corners and with 100 mm overlaps between sheets of StarTex. High impact areas: An additional reinforcement layer of Baumit StarTex (meeting at the edges but not Product Data Sheet: Baumit StarTex. Revision 01/12.

Open the catalog to page 1
Baumit StarTex - 2

Product Data Sheet overlapping!) embedded in a tight coat of contact mortar may be applied prior to the main reinforcement layer and left to stand for at least 24 hours. The sheets of StarTex in the following reinforcement layer must then be stagger bonded over the previous layer. In addition to the cited standards, please refer to the current valid version of the Baumit Installation Guidelines for external wall insulation systems! Further information The air, material and substrate temperature must be above 5° C during application and curing. Protect the facade from direct sunlight, rain...

Open the catalog to page 2

All Back to Earth (SW) Ltd catalogs and technical brochures

  1. Fixit 222

    2 Pages