Safety Instructions
  • Only qualified technicians should operate the device, adhering to safety warnings to prevent electric shock, injury, or damage.
  • Disconnect power before removing covers and avoid direct exposure to the light source.
  • Ensure the device is earthed and used within the temperature range of -10°C to 45°C.
  • Modifications void the warranty and may cause damage or injury.
Features
  • Power Supply: AC100-240V, 50/60Hz, 550W consumption.
  • Light Source: LED with 7000K or 8000K color temperature, lifespan over 20,000 hours.
  • Movement: Pan 540º/630º, tilt 270º with advanced repositioning.
  • Colors and Gobos: CMY color mixing, CTO, rotating gobo wheel with interchangeable gobos.
  • Control: DMX-512 with 31/29/50 channel modes, strobe effect, motorized zoom, and focus.
  • Display: Full-color LCD with optional rechargeable battery and 180° rotation.
Fixture Overview
  • Components include LED assembly, display, rotary knob, handles, and DMX connections.
Dimensional Drawings
  • Dimensions provided for the fixture, gobo filter, and color filter.
Installation Instructions
  • Qualified personnel must perform installation, securing with a secondary safety attachment.
  • Installation must support 10 times the device's weight.
  • Use omega brackets and safety cables, maintaining a safe distance from flammable materials.
DMX-512 Control Connection
  • Connect devices in series using XLR cables; use a DMX terminator for long distances or noisy environments.
Device DMX Start Address Selection
  • Set the DMX starting address for each fixture for correct control signal response.
Display
  • Features a rotary knob for menu navigation and settings adjustment, including DMX address and mode selection.
Fade Time and Scene Time
  • Fade and scene times are input manually or by external sources.
DMX Address Configuration
  • Set DMX address through a menu system using a rotary knob.
User Mode Configuration
  • Define custom channel orders and switch between user modes, setting maximum channels and selecting channel values.
Options Menu
  • No DMX Status: Options to hold last DMX status, close shutter, or run automatic sequence.
  • Pan and Tilt Reverse: Reverse movement direction.
  • Pan Degree: Select between 630 or 540 degrees.
  • Feedback: Enable/disable feedback for pan/tilt movement.
  • Hibernation: Device enters standby if no DMX signal is detected for a set time.
Service PIN
  • Functions include cross-loading software and clearing LED timers.
Fans Control
  • Set fan speed to auto, stage, studio, or silence modes.
Display Settings
  • Options to shut off display, flip display, activate key lock, and enable display flash.
Signal Select
  • Choose between DMX and WDMX signals.
Temperature Display
  • Switch between Celsius and Fahrenheit.
Wireless DMX
  • Activate/deactivate wireless DMX and reset connection.
Dim Curve and Refresh Rate
  • Select dimming curves and refresh rates.
Gobo Correction and Trigger Settings
  • Options for gobo correction and setting devices as slaves or running auto programs.
Reset Default
  • Restore factory settings.
Information Section
  • Displays time-related information such as current time, total life hours, last run hours, and LED hours.
Error Messages and Troubleshooting
  • Error messages related to BLADE components occur due to magnetic-indexing circuit malfunctions or defective stepper motors.
Cleaning and Maintenance
  • Regular inspection and maintenance ensure longevity and performance.
  • Weekly cleaning of lenses and fans, quarterly electrical checks recommended.
  • Use a moist, lint-free cloth for cleaning; avoid alcohol or solvents.
  • Order genuine spare parts from local dealers.
Additional Notes
  • Disclaimer: Errors and omissions excepted; information subject to change without notice.
See more

Catalog excerpts

LEVANTE-1

AYRTONManuel d’utilisation KEEP THIS MANUAL FOR FUTURE NEEDS

 Open the catalog to page 1
LEVANTE-2

7. DMX-512 CONNECTION WITH DMX TERMINATOR 12 8. DEVICE DMX START ADDRESS SELECTION 13

 Open the catalog to page 2
LEVANTE-3

1. SAFETY INSTRUCTIONS 1.1. IMPORTANT SAFETY WARNING This device has left the factory in perfect condition.In order to maintain this condition and to ensure safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. In order to install operate and maintain the lighting fixture safely and correctly we suggest that the installation and operation be carried out by qualified technicians and these instructions be carefully followed. CAUTION! HIGH VOLTAGE. RISK OF SEVERE OR FATAL ELECTRIC SHOCK CAUTION! ALWAYS DISCONNECT MAINS...

 Open the catalog to page 3
LEVANTE-4

• This device falls under protection-class I.Therefore, it is essential that the device be earthed. • If eitherlenses or displayare damaged (damage may include cracks or gashes in the material) they must be replaced. • Electrical connections, such as replacing the power plug, must be performed by a qualified person. • Make sure that the available voltage is not higher than that which is stated at the end of this manual. • Make sure the power cord is never crushed or damaged by sharp edges. Ifthis should be the case, replacement of the cable must be done by an authorized dealer. • If the external...

 Open the catalog to page 4
LEVANTE-5

may suffer damage and the warranty becomes void.Furthermore, any other operation may lead to short-circuits, burns, electric shocks etc. 2. FEATURES POWER SUPPLY • AC100-240V-, 50/60Hz • Power Consumption: 550W LIGHT SOURCE • LED: White LED 330W 7000K ±400K Color Temperature, high CRI @ LEVANTE TC White LED 330W 8000 ± 500K Color Temperature @ LEVANTE S • Extremely long Life: >20,000H MOVEMENT • Pan movement: 540° /630°Optional (16 bit) • Tilt movement: 270° (16 bit) • Advanced moving system: fast, stable and quite, auto x-y repositioning COLORS • CMY color mixing + CTO • 1 Color wheel: 7 dichroic...

 Open the catalog to page 5
LEVANTE-6

SOFTWARE 8 pre-installed programs available upon selection Upgrades fast and convenient through DMX cable with DMX-512 controller Reset DMX address remote lamp control reset can all be done by the DMX controller Running time of fixture on display for reference OTHER SPEC Input signal isolation guarantees stable signal transmission without interference Advanced RDM function WEIGHT Net weight: 22 kg

 Open the catalog to page 6
LEVANTE-7

1) LED Assembly 2) Display 3) Rotary knob 4) Handle 5) Lock button

 Open the catalog to page 7
LEVANTE-8

4. DIMENSIONAL DRAWINGS 4.1. Fixture Dimension

 Open the catalog to page 8
LEVANTE-9

4.2. Gobo Filter Dimension 4.3. Color Filter Dimension

 Open the catalog to page 9
LEVANTE-10

A PLEASE CONSIDER THE RESPECTIVE NATIONAL NORMS DURINGINSTALLATION. THE INSTALLATION MUST ONLY BE CARRIED _OUT BY A QUALIFIED PERSON._ • The applicable temperature for the lighting is between -10°C to 45°C. Do not use the lighting under or above the temperature. • The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation. • The installation must always be secured with a secondary safety attachment, e.g.an appropriate safety rope. • Never stand directly below the device when mounting, removing or servicing...

 Open the catalog to page 10
LEVANTE-11

• Fix the clamp to the bracket by tightening the M12 nut and boltto the bracket through the 013 hole in the middle of the bracket. • Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the device. Tighten the quick-lock fasteners fully clockwise. • Install the second Omega holder. • Pull the safety cable through the holes on the bottom of the base and over the trussing system or another suitable rigging point. Insert the end into the carabiner and tighten the safety screw. Important: This step is very important to ensure safe rigging of the fixture....

 Open the catalog to page 11
LEVANTE-12

• Be sure this fixture is kept at least 0.1m away from any flammable materials (decoration etc.). • Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Important: Overhead rigging requires extensive experience , including (but not limited to) calculatingworking load limits, specifying installation/ rigging materials, and periodic safety inspection of all installation material as well as the device.If you lack these qualifications, do not attempt therigging of this device yourself. Improper installation/...

 Open the catalog to page 12
LEVANTE-13

6. DMX-512 CONTROL CONNECTION Connect the provided male side of the XLR cable to the femaleXLR output of your controller and the female side of the XLR cable to the male XLR input of the device.You can connect multipledevices together in a serial fashion.The cable needed should be two core screened cable with XLR input and output connectors.Please refer to the diagram below. Address 101 Series connection number 7. DMX-512 CONNECTION WITH DMX TERMINATOR For installations where the DMX cable has to run over a long distance or is in an electrically noisy environment such as in a discotheque it is...

 Open the catalog to page 13
LEVANTE-14

8. DEVICE DMX START ADDRESS SELECTION All fixtures should be given a DMX starting address when using a DMX signal so that the correct fixture responds to the correct control signals.This digital starting address is the channel number from which the fixture starts to listen” the digital control information sent out from the “ to DMX controller.The allocation of this starting address is achieved by setting the correct address number on the display located on the base of the device. You can set the same starting address for all fixtures or a group of fixtures addresses for each fixture individually....

 Open the catalog to page 14
LEVANTE-17

9.1.1. Set DMX Address With this function, you can adjust the desired DMX-address via the Display. 1. Double click to enter the menu. 2. The display will show " ADDRESS ”. 3. Double click to enter then display " Set DMX Address ”. 4. Turn the rotary knob clockwise then display " A001~AXXX ”. 5. Long press to exit the menu. 9.2.1. User Mode With this function, you can create user defined channel orders. 1. Double click to enter the menu, turn the rotary knob clockwise to display " USERS MODE ” . 2. Double click to enter to edit. 3. Turn the rotary knob clockwise to display " User mode ” .Double...

 Open the catalog to page 17

All AYRTON catalogs and technical brochures

  1. GHIBLI

    20  Pages

  2. DIABLO

    40  Pages

  3. HURACAN

    48  Pages

  4. MISTRAL

    36  Pages

  5. COLORSUN 200

    4  Pages

  6. VERSAPIX 100

    4  Pages

  7. WILDSUN 500 C

    4  Pages

  8. ARCALINE 2 3G

    4  Pages

  9. ICECOLOR 1000

    2  Pages

  10. ICECOLOR 500

    2  Pages

  11. ICECOLOR 250

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.