The OrangeLink FD-WA01 is a Wiegand interface module designed for integration with third-party readers in access control systems. It allows existing systems to be upgraded to OrangeLink while retaining current readers. The module supports various reader types, including those for harsh environments and explosion-proof applications.

Functional Characteristics
  • Compatible with standard Wiegand interface output readers.
  • Configurable via XAtlas software for 26-bit and other Wiegand formats.
  • DIN rail mountable with visual fault and alarm indicators.
  • Connects to FD-BUS via RJ45, with parallel connectors for easy reconnection.
  • Galvanic separation from local ground, with power supply for connected readers (12 Vdc, 500 mA).

Protection Features
  • Protection against polarity reversal, voltage surges, and negative voltage peaks.

Modes of Operation
  • Data acquisition from any standard Wiegand output reader.
  • Three outputs for controlling reader LEDs and buzzer.
  • Programmable for multiple Wiegand formats (26, 35, 37, 40 bits).

Visual Indicators
  • Green LED: Steady when operational.
  • Red LED: Steady during alarms or faults.
  • Yellow LED: Flashes during communication.

Technical Specifications
  • Dimensions: 62x95x59 mm (4 DIN units).
  • Weight: 106g.
  • Power Supply: 8VDC to 14VDC, 48 mA nominal.
  • Operating Temperature: 0 to 50°C.
  • Humidity: Up to 90% without condensation.
  • FD-BUS Connection: 2 RJ45 ports, RS485 interface, 11,500 baud rate.
  • Address Selector: 0 to 63 via DIP switches.

Compliance
  • Complies with Directives 89/336/EEC, 93/68/EEC, 92/31/EEC and standards EN60950, EN 55022, EN 55024.
See more

Catalog excerpts

FD-WA01-1

The FD-WA01 allows to connect any third party's reader with a standard wiegand interface output. With FD-WA01 an existing Access Control system can be replaced by OrangeLink saving the already installed readers. The FD- WAOI can also be used to integrate into the OrangeLink system particular readers for specific applications like long range proximity readers, readers fo very harsh envinroment, explosion proof readers, etc. The FD-DA01 can be easely configured by the XAtlas software to read standard 26 bits wiegand format or other configurable formats.. ♦ Visual fault and/or alarm indication ♦ Connection to FD-BUS through an RJ45 connection ♦ Double RJ45 connector (internally in parallel) for easy reconnection to the FD-BUS. ♦ Galvanic separation of the FD-BUS backbone from the local reference ground ♦ 3 open collector output sto connect leds and buzzer of the connected reader ♦ 1 tamper input from the connected reader ♦ Power supply to the connected reader (12 Vdc, 500 mA) The equipment is protected against the following events: ♦ polarity reversal on the cables (RJ45) connecting to the FD-BUS ♦ voltage surge in the power supply ♦ negative voltage peaks at outputs with inductive loads ♦ The FD-WA01 module is part of the Orangelink system and can perform the data acquisition functions from any reader with a standard wiegand output. It has also three outputs to control the leds and buzzer of the connected reader. The wiegand interface can be programmed to accept the standard 26 bits format or the 35 (Corporate 1000 HID®), 37, 40 bits formats.

 Open the catalog to page 1
FD-WA01-2

Power supply: internal circuit Power supply: optically isolated Power supply input Wiegand interface Tamper input_ Operating temperature Relative humidity FD-BUS connection Differential RS485 serial interface Baud rate (nominal) 11,5000 baud Optically isolated floating ground (500V insulation) Address selector From 0 to 63 through binary coding on 6 DIP switches Indicator signals Other functions Protection against reversed polarity at input Tamper switch for alarm if casing is opened Functional diagnosis of outputs with alarm indicator in the event of faults

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.