FD-RC0x OrangeLink Bidirectional 125 KHz (HID) reader Functional characteristics The FD-RC01 and FD-RC02 are card readers module which can read data from HID proximity cards with the following characteristics: ♦ Able to energize HID cards at 125HHz at a distance of about 2 cm from the antenna (antenna is located at the center of the reader) ♦ Able to read the data on HID cards ♦ Read data registration (entry/exit) by means of photo sensors on the left and right of the reader ♦ Visual indications through 2 multicolored LEDs (red/green/yellow/blue) in the little arrow symbols on either side of the reader ♦ Indication of a field present by sequential illumination of the blue wave symbols on either side of the reader ♦ Audible signal through an internal buzzer ♦ Connection to the FD-BUS using SPP (Serial Proprietary Protocol) at a speed of 115.2 Kbaud (default) or 19.2 Kbaud ♦ Address selection for the reader by means of a rotary switch on the back of the device ♦ Double connector (internally in parallel) for easy reconnection to the FD-BUS. Only FD-RC02 ♦ Display of alphanumeric and semi-graphical information on an LCD display, on 2 rows of 16 characters with BLUE backlight ♦ Automatic disabling of the display backlight to save energy when operated from the battery Protection The equipment is protected against the following events: ♦ polarity reversal on the cables (RJ45) connecting to the FD-BUS ♦ voltage surge in the power supply and data lines Modes of Operation The FD-RC0x module can read HID® contactless cards in registered and non-registered mode. ® ♦ In registered mode (entry/exit for attendance registration), the HID card is read by presenting the card at the luminous wave symbols on the left or right of the reader. ® ♦ In non-registered mode (access control) the HID card is read by presenting the card at the center of the reader. Visual indicators The FD-RC0x module can give the user indications by means of: ♦ ♦ ♦ ♦ alphanumeric LCD display (only FD-RC02) 2 multicolored LEDs located in the arrow symbols blue LEDs in the wave symbols buzzer FD-RC0x-DS-02-en.doc The most common indications are as follows: ♦ When switched on, the module displays the address previously set with the rotary switch. ♦ If there is no polling from the Field Manager, the module displays the message “No communication” and both arrows flash yellow. ♦ When the module receives the configuration from the Field Controller, the blue wave symbols on either side of the reader begin flashing. ♦ On access grant, the arrow symbol corresponding to the direction of passage is lit green. and an audible signal is given. Pg. 1/2
Open the catalog to page 1OrangeLink Parameter Dimensions Weight Power supply Processor Connections FD-BUS communication Rice transmitter Bidirectional reading Operating temperature Protection class Address selector Relative humidity Mounting Indicator signals Other functions FD-RC0x Description 130x70x43mm 210g Through the FD-BUS connectors From 8VDC to 14VDC 160 mA nominal (at 14VDC) 200 mA with LEDs lit (at 14VDC) 100 mA with backlight off (at 14VDC) (only FD-RC02) P89C664 Philips at 11.0592 MHz FD-BUS (2 RJ45s in parallel) with RS485 and power supply Differential RS485 serial interface Baud rate (nominal) 11,5000...
Open the catalog to page 22 Pages
4 Pages
2 Pages
3 Pages
2 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
2 Pages
8 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
1 Page