Catalog excerpts
Data Sheet ENIGMA TRIM COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNVGL = ISO 9001 = DESCRIPTION False Ceiling with steel or aluminum side by side tiles laid on T24 hidden structure, resulting in an aligned and uniform effect. STRUCTURE PROFILE SECTION SECTIONS RIGHT EDGE BEVELLED EDGE TYPE Lay-in tiles Right edge or bevelled edge to 45° Regular and asymmetrical composition Enigma Trim tiles have an unlocking system and allow the composition of false ceilings with side by side and alined panels. MATERIAL AND WEIGHT Aluminum 6/10: Aluminum 7/10: Steel 5/10: Steel 6/10: 1,92 kg/sqm 2,24 kg/sqm 4,60 kg/sqm 5,52 kg/sqm HIDDEN STRUCTURE Steel Strong Easy T24 Steel Strong Easy Antisismico T24 Steel Strong Easy Fox T24 CERTIFICATIONS FLEXION RESISTANCE Maximum span mm 1200 - 1 Class DURABILITY OF POST-PAINTED ITEMS C Class DURABILITY OF GALVANISED ITEMS B Class RELEASE OF DANGEROUS No release of dangerous substances according to European Law EN 13964:2014 REACTION TO FIRE According to UNI EN 13501-1: plain or perforated tiles with Viledon Plus A1 Class perforated tiles with standard Viledon A2s1d0 Class structure A1 Class ACOUSTIC TEST Refer to Atena acoustic catalogue. MAXIMUM BEARING CAPACITY Str. Easy T24 and Easy Antisismico Str. Easy Fox T24 model 600x600: 10 kg/sqm Data Sheet “Enigma Trim” - rev 2 of 14/09/2017 - pag. 1 of 6 H
Open the catalog to page 1Data Sheet “Enigma Trim” - rev 2 of 14/09/2017 - pag. 2 of 6 HIDDEN STRUCTURE STEEL STRONG T24 clips for the earliest laid tiles ENIGMA TRIM tiles can be laid on all T24 structures. TILE SECTION RIGHT EDGE TILE SECTION 45° BEVELLED EDGE Easy hook Antisismico hook Main carrier hook *Verify the interaxe according to the load at m 2 . All dimensions are nominal and expressed in millimeters. All technical specification data and information can be changed without advise. For further information please contact sales department: tel. + 39 0421 75526 commerciale@atena-it.c
Open the catalog to page 2Data Sheet “Enigma Trim” - rev 2 of 14/09/2017 - pag. 3 of 6 HANGER HOOK INSTALLATION STEPS: Draw the lines of the perimeter frame. Determine the height of the ceiling with a level and mark it with a string. Proceed with the installation of structure: 1. Install the wall angles with nails, screws and / or plugs suitable to the wall material. 2. Fix the hangers according to the type of ceiling to be installed. 3. Install the main runners with an interaxe of 1200* mm. 4. Proceed with the installation of 1200 mm cross T profiles in to the main carrier. 5. Install 600 mm Cross T in to 1200 mm...
Open the catalog to page 3Data Sheet "Enigma Trim” - rev 2 of 14/09/2017 - pag. 4 of 6 model 600 x 600 mm ENIGMA TRIM INCIDENCES STEEL STRONG EASY T24 - EASY FOX STRUCTUREID DESCRIPTION MATERIAL QUANTITY 1 S it refers to the weight of structure only S + P false ceiling total weight structure and tile - without hangers weight tiles weight refers to plain model PACKAGING SPECIFICATION PACKAGING the grey part of the code changes according to the tiles specification All dimensions are nominal and expressed in millimeters. All technical specification data and information can be changed without advise. For further...
Open the catalog to page 4Data Sheet “Enigma Trim” - rev 2 of 14/09/2017 - pag. 5 of 6 T E C H N I C A L S P E C I F I C AT I O N MATERIAL AND COLOR: • Aluminum 5/10 • Aluminum 6/10 • Steel 5/10 - 6/10 White | Silver White | Silver White | Silver Postpainted similar to RAL 9010 and RAL 7035 (gloss and matt) Postpainted all RAL color gloss and semi-gloss SILVER postpainted similar to RAL 9006 and all matt RAL colors. See “Colors and Materials” data sheet FINISHING: Plain surface Perforated surface: • Perforation type • Hole • Diagonal or parallel perforation • % perforated area Read Atena Perforations data sheet...
Open the catalog to page 5Data Sheet “Enigma Trim” - rev 2 of 14/09/2017 - pag. 6 of 6 CLEANING, MAINTENANCE AND REMOVAL Cleaning and maintenance require some attention and care even though are easy to make and don’t take much time. It is necessary to use neutral and not aggressive soaps. In case of any damage, tiles can be repainted or replaced. False ceilings maintenance usually refers to: placing, alignment or replacement of damaged or broken tiles. Panels can be also removed for restoration or maintenence of the system below. The maintenance work shall be appointed to:specialised workers trained with technical...
Open the catalog to page 6All Atena spa catalogs and technical brochures
-
FLYER_Atena_Trigon_Eng
5 Pages
-
Atena_Trigon_Ds_Eng
6 Pages
-
METAL CELLS
29 Pages
-
METAL BAFFLE
35 Pages
-
ATENA H+
27 Pages
-
BOOK
43 Pages
-
Atena Façades
13 Pages
-
ATENA ENJOY
5 Pages
-
DRY CONSTRUCTION SYSTEMS
17 Pages
-
METAL MESH
47 Pages
-
HOSPITAL SYSTEMS
32 Pages
-
BAFFLE SYNCRO UP
8 Pages
-
doghe - grigliati
41 Pages
-
vivi
49 Pages
-
STEEL STRONG
21 Pages
-
Metal Shapes
79 Pages
-
Metal Series
47 Pages
-
MULTILEVEL 3D cube
2 Pages
-
Flexit newsletter
2 Pages
-
Atena SISTEMI OSPEDALIERI
24 Pages
-
Atena METAL SOUND Rev01
34 Pages
-
ATENA EnigmaLink
7 Pages
-
ATENA GESSO RIVESTITO REV02
56 Pages
-
Atena Cat Navale
11 Pages
-
ATENA ANTISISMICO
28 Pages
-
ATENA RIVESTIMENTI ESTERNI
40 Pages
-
ATENA LAMIERA STIRATA
20 Pages
-
ATENA GESSO RIVESTITO
56 Pages
-
Atena Naval sector
11 Pages
-
Atena Special Finishing
16 Pages
-
Atena Metal Sound
34 Pages
-
Atena References
76 Pages
-
Atena Hospital Systems
24 Pages
-
CUSTOM-MADE CLADDINGS
40 Pages
-
Easy Antiseismic System
28 Pages
-
LINE UP FOR EXTERNAL COVERINGS
10 Pages
-
T-BAR LED Smartlight
6 Pages
-
ATENA SILVER SEA
5 Pages