Atena_Trigon_Ds_Eng - 1

METAL CELLS TRIGON Open cell Trigon: Product not available in France. | Produit non disponible en France. PANELS DIMENSIONS ~693x1386 mm rhomboidal shaped Meshes Open area OPEN CELL ELEMENTS Base 10 H41 interlocking profiles INTEGRATED STRUCTURE Main profiles: 2771,3 mm Spacer: 1380 mm Photo by Damir Kopezhanov on Unsplash |Render Atena S.p.A. OPEN CELL MATERIALS 5/10 Aluminum HANGERS Standard double hanger Ø4 mm with spring 12 WALL ANGLES “C” 25x42x10 mm wall angle with the same material and finishing of the open cell COLORS Atena standard white and silver pre-painted aluminum Wood effect pre-painted aluminum RAL/NCS Post-painting ACCESSORIES Lighting adapters Technical Data Sheet atena s.p.a. has a quality management system certificated by rina in compliance with ISO 9001 ELEMENT QUANTITY PER MODULE 600x1200 PIECES/SQM LM/SQM LOWER ELEMENTS INTERM. ELEMENTS SUPERIOR ELEMENTS * For specific project requirements, the hanger incidence may vary. Please check with the Atena S.p.A technical department. WOOD ATENA RANGE ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 1 of 6 Weights kg/m2, without hanger

Open the catalog to page 1
Atena_Trigon_Ds_Eng - 2

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 2 of 6 TECHNICAL PERFORMANCES FLEXION RESISTANCE Maximum span mm 1200 - 1 Class EN13964 CORROSION RESISTANCE Galvanized steel products: C2 Class Pre-painted galvanized steel products: C3 Class Post-painted galvanized steel products: C4 Class Pre/post-painted aluminum products: C5 Class (RH%) RELATIVE HUMIDITY RESISTANCE Galvanized steel products: ≤ 90% Pre/post-painted galvanized steel products: > 90% Stainless steel and aluminium products: > 90% Wet cloth with warm water and neutral non-abrasive detergents. COLOR...

Open the catalog to page 2
Atena_Trigon_Ds_Eng - 3

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 3 of 6 SECTION VIEW *verify interaxes and hanger models according to the load at m 2 the antiseimic report and particular conditions when required.The fastening must be checked with regard to the loads, the anchoring base features and the installation accuracy, in order not to compromise the stability of the metal ceiling system. Lightings, accessories and systems must not weigh on the metal ceiling system, but must be independently suspended. WALL ANGLE COMPONENT INCIDENCES OPEN CELL PANEL WALL ANGLE - pcs/sqm...

Open the catalog to page 3
Atena_Trigon_Ds_Eng - 4

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 4 of 6 1/2 Draw the lines of the primeter frame. Determine the height of the ceiling with a level and mark it with a string. Install the wall angles with mails, screws and/or plugs suitable to the wall material. 3 Fix the hangers according to the type of ceiling to be installed*. Hook 2771 mm main profiles on the hangers*. Proceeed with the installation of spacers with a 693 mm interaxe. Lay the assembled open cell panels on the structure. *verify interaxes and hanger models according to the load at m 2 the...

Open the catalog to page 4
Atena_Trigon_Ds_Eng - 5

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 5 of 6 CLEANING, MAINTENANCE AND REMOVAL INSTRUCTIONS Cleaning and maintenance require some attention and care even though are easy to make and don’t take much time. It is necessary to use warm water and neutral and non-abrasive detergents. Metal ceilings maintenance usually refers to: placement, alignment or replacement of damaged or broken modules (panels, staves, baffles, open cells) which can be also removed for restoration or maintenence of the system below. In order to ensure an excellent results, the...

Open the catalog to page 5
Atena_Trigon_Ds_Eng - 6

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 6 of 6 NORMATIVE REQUIREMENTS Atena S.p.A. has adopted a quality management system in compliance with the UNI EN ISO 9001 standard. All Atena metal ceilings are produced for indoor applications, in compliance with Technical Standards for Construction NTC 2018 and relative circular requirements, the Minimum Environmental Criteria CAM (Ministerial Decree 11 October 2017), the specific technical standards applicable UNI EN 13964 and 14195. Each Atena S.p.A. product has its own DOP (CE Declaration of Performance)...

Open the catalog to page 6

All Atena spa catalogs and technical brochures

  1. METAL CELLS

    29 Pages

  2. METAL BAFFLE

    35 Pages

  3. ATENA H+

    27 Pages

  4. BOOK

    43 Pages

  5. Atena Façades

    13 Pages

  6. ATENA ENJOY

    5 Pages

  7. ENIGMA TRIM

    6 Pages

  8. METAL MESH

    47 Pages

  9. vivi

    49 Pages

  10. STEEL STRONG

    21 Pages

  11. Metal Shapes

    79 Pages

  12. Metal Series

    47 Pages