Flat lock shingle for façade

Flat lock shingle for façade
1 / 10 PagesView full catalog

Flat lock shingle for façade

Product catalog summary
Main Characteristics
The flat lock joint façade cladding system, also known as the shingle system, is designed for both flat and curved façades. It is characterized by its lightweight, durability, and low maintenance, offering a range of design possibilities for both classical and contemporary architecture. The system is typically vented, with hidden and indirect fixing, requiring continuous support and using material thicknesses between 0.7 to 0.8mm.

Principal Joints
The system uses a flat lock joint, or single lock cross welt, applied longitudinally and vertically, creating a step between adjoining shingles. This involves a 180-degree fold along the shingle perimeter, with outward and inward bends to accommodate clips and adjoining shingles. Joint dimensions range from 23mm to 30mm, with material usage approximately three times the fold dimension.

Fixing and Installation
Installation involves indirect fixing using clips hooked into the outward folds of shingles and attached to the substrate. The system allows for free thermal movement, with the number of clips adjusted according to wind loading. Installation proceeds from the bottom to the top of the façade, with joints designed to effectively shed rainwater.

Appearance
The flat lock joint provides a refined joint appearance, with shadow effects visible in sunlight. Shingles can be arranged in horizontal, vertical, or angled layouts, with design coordination enhancing the harmony of the façade. The system allows for subtle quilting effects under different lighting conditions.

Horizontal and Vertical Layouts
Horizontal layouts include staggered, stepped, and random designs, with shingle lengths typically limited to 2m. Vertical layouts can accommodate longer shingles but require careful handling. Designs can be staggered or stepped, with coordination of openings for an orderly appearance.

Other Layouts
Shingles can be laid at 45-degree angles or in rhomboid designs, with tessellating shapes ensuring proper water shedding. Various layout designs are possible, enhancing the building's geometry.

Substrates and Façade Construction
Flat lock shingles require a supporting substrate, typically ventilated with an air layer. Common materials include soft wood, OSB, plywood, or lacquered steel trapezoidal sheets. National building codes should be consulted for the use of combustible materials.

Summary
The system is suitable for both flat and curved façades, utilizing a single lock cross welt joint. It employs material thicknesses from 0.65 to 1.0mm, with various elZinc® finishes available. The system is economical, quick to install, and adaptable to different layout designs. For detailed technical information, consult the technical literature or contact the technical advisory service.
See more

Catalog excerpts

Flat lock shingle for façade-1

Façade cladding systems overview Flat lock joint

 Open the catalog to page 1
Flat lock shingle for façade-2

Substrates and facade construction 14

 Open the catalog to page 2
Flat lock shingle for façade-3

4 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 5 Main characteristics The system is suitable for flat and curved façades. Also known as the shingle system, it offers a convincing combination of delicate appearance, economy, and real ease of installation. It is a very durable, light-weight and very low maintenance construction. The shingles can be set at various orientations and in different geometric shapes, giving many design possibilities that allow the system to be equally well adapted to classical or contemporary architecture....

 Open the catalog to page 3
Flat lock shingle for façade-4

6 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 7 Principal joints The flat lock joint, also known as the single lock cross welt, is used longitudinally and vertically in this system. It generates a jump between the faces of adjoining shingles. The flat lock joint is formed by bending a 180 o fold (hem) along the perimeter of each shingle. Along the top edge and one of the sides the fold is bent outwards, and along the bottom edge and the other side it is bent inwards. The outward fold receives the clips and the next shingle...

 Open the catalog to page 4
Flat lock shingle for façade-5

8 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 9 Appearance The flat lock joint is quite discrete and so the general appearance of the cladding is one of fine joints. Nevertheless, during sunny weather, the shadow cast by the joint can be quite visible. Depending on the design of the layout and the dimensions of the shingles, the appearance can be either directional or non-directional so, visually, it is a versatile system. The shingles are normally set out horizontally, vertically or at 45o, however for reasons of design...

 Open the catalog to page 5
Flat lock shingle for façade-6

10 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 11 Horizontal layouts The small step between each shingle gives the architect the opportunity to employ them creatively in the design to generate varied shadow effects and geometric shapes, thus enabling different ‘sensations’ to be communicated. As an example, a façade in which window openings line up with the flat lock joints gives the feeling of order and formality. On the other hand, a design in which the continuous skin of the façade is randomly ‘punched’ through by openings...

 Open the catalog to page 6
Flat lock shingle for façade-7

12 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 13 Vertical layouts Installation of longer shingles in the vertical does not present quite the same handling problems as in the horizontal, but still a shingle longer than 2m is easily bent on site and requires careful hand- Other layouts ling. These layouts are normally used on ‘vertical’ buildings, where they look to enhance the building’s geometry even if using a ‘flat’ system with discrete joints. Vertical staggered or stepped de- signs can be used to achieve this effect....

 Open the catalog to page 7
Flat lock shingle for façade-8

14 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 15 Substrates and façade construction Flat lock shingles are not self-supporting and require a fully or almost fully supporting substrate against which they rest and to which their clips are fixed. The substrate is usually ventilated with an air layer (minimum 2cm) between it and the insulation. Three examples of the many possibilities that exist are shown here. For more detailed information on supporting materials and wall construction, please consult our technical documentation....

 Open the catalog to page 8
Flat lock shingle for façade-9

16 | Façade cladding systems - Flat lock joint – an overview Façade cladding systems - Flat lock joint – an overview | 17 Flat and curved façades, soffits. Principal joint Single lock cross welt along all edges of shingles. Minimum thickness Maximum thickness Minimum radius depends on the size of the singles – contact us for more detailed information. Produces a jump of about 5mm between shingles. Normally uses between 70 and 90mm of material. 0,7 or 0,8mm is normally used on façades. elZinc Rainbow® blue elZinc Rainbow® green elZinc® Natural elZinc Slate® elZinc Rainbow® brown elZinc Rainbow®...

 Open the catalog to page 9
Flat lock shingle for façade-10

Factory ASTURIANA DE LAMINADOS, S.A. has developed the instructions and recommendations herein with the aim of providing a better service for its customers. It is generic information for standard installation of elZinc® products in a European climate. This information must not substitute the considerations and requirements that, in each project, architects, designers and consultants may offer. ASTURIANA DE LAMINADOS, S.A. does not accept any responsibility therefore for any damage incurred to third parties, directly or indirectly by the misapplication, misinterpretation or general incorrect use...

 Open the catalog to page 10